A medida que los cables van de un punto de conexión a otro, deben colocarse en algún tipo de conducto para protegerlos del daño físico que puede resultar de la abrasión, contracción y expansión, el sol, roedores o productos químicos. El término conducto se refiere a una variedad de diferentes tipos de formas de protección plásticas o metálicas que se pueden usar. El tipo apropiado de conducto variará según:

  • Dónde se ubicará los conductores y conducto: Qué ofrecerá la mejor protección dadas las condiciones. Por ejemplo, si el conducto se ubicará en el exterior, es necesario elegir un conducto que sea apropiado para su uso en condiciones de humedad.
  • Construcción de edificios: ¿Se colocará el conducto y conductores dentro de una pared? Si se va a ejecutar dentro de una pared, se debe elegir un conducto adecuado. ¿En la superficie de una pared? Varios tipos de conductos pueden ofrecer protección suficiente, pero algunos pueden ser más agradables estéticamente que otros.
  • El código eléctrico local y prácticas locales: Es la mejor práctica seguir el código eléctrico en cualquier lugar, pero las prácticas locales pueden requerir practicas diferentes.
  • Disponibilidad local de materiales: Algunos componentes y materiales no están disponibles en todas partes.

Tipos de conducto

Different conduit types shown with a cross section and coupling. (1) Metallic conduit (2) PVC conduit (3) Flexible metal conduit (4) Flexible non-metallic conduit (5) Cable tray

There are several broad categories that most types of conduit fit into. The actual appearance of the conduit, connectors, and couplers may vary from place to place. Connectors are used to connect the conduit to a junction box. Couplers are used to connect sections of conduit together as they typically come in 3 m or 10' sections.

Metallic conduit

Metallic conduit offers excellent protection under appropriate conditions but may not be the cheapest, simplest, most widely available option. That being said, metallic conduit will result in a high-quality installation if used appropriately. Should not be buried. It can be bent into angles with appropriate bending tools or sections can be bought that are pre-bent to specific angles (15°, 30°, 45°, 90°). There are a few different types of metallic conduit available which are classified based upon the thickness of the walls of the tubing:

  • Electric metallic tube (EMT): The thinnest options which is intended for use indoors - on walls or inside walls.
  • Intermediate metal conduit (IMC): A thicker-walled option that offers more durable protection. Can be installed outdoors with appropriate connectors/couplers/junction boxes.
  • Rigid metal conduit (RMC): The thickest-walled option that is the most durable. Can be installed outdoors with appropriate connectors/couplers/junction boxes.

PVC plastic conduit

PVC conduit offers excellent protection under nearly all conditions, is cheap, simple, and common. PVC conduit is frequently used inside walls and on the surface of walls in many parts of the world. PVC conduit can used in wet locations or buried underground as it does not corrode and can be made watertight by using appropriate fittings and sealants. It is possible to bend PVC by heating the conduit, but this can pose challenges in some locations, therefore pre-bent sections are typically used to make bends (15°, 30°, 45°, 90°).

Flexible metal conduit

Flexible metal conduit (FMC) is simple to work with and commonly available. It has the advantage of being flexible, meaning that it is often possible to avoid many of the challenges that come with putting bends into other types of conduit. Traditional FMC is rated only for indoor use, but there is a rubberized version called Liquidtight FMC that (LFMC) that can be used outdoors, in wet locations, or buried in short sections if necessary.

Flexible non-metallic conduit

Flexible non-metallic conduit (FNC) is simple to work with and commonly available. It is only rated for indoor use and does not offer as durable of protection as the other options but is typically fine in most locations.

Cable tray

Cable tray is a term that refers to many different types of products, but the most commonly used is made out of a rectangular PVC channel with a removable lid. It may come with an adhesive backing as well. This type of cable tray is commonly used in many locations to install lighting and outlet circuits on the surface of walls. This is a common practice in many locations as it minimized installation time and can keep costs low, but cable trays do not offer the best protection and do not last as long as the other options.

Conduit size

Various sizes of electric metallic tube with cross section, coupling and connector.
Recommended percentage of space occupied by 1, 2, 3+ wires in a conduit.

It is necessary to choose a size of conduit that is appropriate for the number of wires that will be installed in the conduit. A conduit that is too small presents various problems as wires may not be able to pass through bends, they may be damaged as they are pulled through the conduit and they may be unable to properly cool themselves. Conduits typically come in standard sizes:

Size (standard in inches) Size (metric in mm)
1/2" 16 mm
3/4" 21 mm
1" 27 mm
1-1/4" 35 mm
1-1/2" 41 mm
2" 53 mm
2-1/2" 63 mm
3" 78 mm
3-1/2" 91 mm
4" 103 mm

The number of a particular type of wire that can fit in a conduit depends on the internal diameter of a conduit, which will vary based upon the conduit type and the wall thickness of the particular conduit. The general guidelines, from the US National Electrical Code, for the amount of space that can be occupied in a conduit is as follows:

  • 1 wire can fill up to 53% of the space inside a conduit.
  • 2 wires can fill up to 31% of the space inside a conduit.
  • 3 or more wires can fill up to 40% of the space inside a conduit.

This can serve as a useful conservative visual guideline or the recommended fill percentage for a given conduit size can be calculated by performing a simple calculation using:

  • The cross-sectional area of the particular size and type of conduit that will be used (can be obtained online, on material specifications sheets or from supplier.
  • The cross-sectional area of the particular wire size and type that will be used (can be obtained online, on material specifications sheets or from supplier. It is not recommended to put more than 2 x 90° bends in any section of conduit between two junction box. More than 2 x 90° bends will make pulling the wire very difficult.

Example 1: A circuit has 3 x 12 AWG THHW wires. Can these wires fit in a 1/2" (21 mm) EMT conduit with 1 x 90° bend?

  • Maximum fill of 40% of the space inside the conduit.
  • Cross-sectional area of conduit ): 195 mm²
  • Cross-sectional area of 12 AWG THHN wire: 11.68 mm²
Maximum cross-sectional conduit fill = 195 mm² × .4 = 78 mm²
Total cross-sectional area for wires = 3 × 11.68 mm² = 35.05 mm²
This configuration will work just fine.

Securing and supporting conduit

Example of a properly supported conduit:
(1) A conduit must be supported near any terminations. (2) A conduit must be supported periodically throughout its length.

All conduit must be properly secured and supported. The electrical code for the project location will specify the minimum distance between supports for a particular type of conduit, although the appropriate distance between supports for the conduit should ultimately be determined based upon what will offer the most protection from damage. All conduit should be snug against the surface that it is being run along rather than drooping or bending. It is important to offer additional support near junction boxes as strain placed on a conduit near a connection can lead to the failure of the connection.