Translations:Simplified minimum PV source size/12/en

From Open Source Solar Project
Jump to navigation Jump to search

Notes/references

  • Location max temp = 40°C
  • Mounting system temperature adder = 25°C
  • Temperature power loss factor = -0.48%/°C
  • Module degradation parameter = 0.9
  • Shading loss parameter = 0.95
  • Soiling loss parameter = 0.95
  • Wiring loss parameter = 0.96
  • Module mismatch parameter = 0.98
  • Energy storage efficiency parameter = 0.75
  • Charge controller efficiency parameter = 0.98
  • Final total loss factor = 0.5