Translations:Simplified minimum PV source size/11/en
Jump to navigation
Jump to search
- MPPT:
- The PV source must be configured to operate below the maximum PV source voltage rating of the charge controller, above the minimum PV source voltage based upon the maximum charging , and below the maximum PV source current rating of the charge controller.
- Nominal system voltage: 12V, 24V, 48V
- Maximum PV source voltage: varies up to 600V
- Minimum PV source voltage: depends upon nominal voltage and charge controller type
- Maximum PV source current: up to 100A+