Example 1: A PV module is rated at 200W. Cell temperature is measured at 35 °C. The specifications for the module state that it has a TkPmp of -.48 %/°C. What should the power output of the module be?
- Temperature loss factor = 35°C - 25°C × -.48 %/°C
- Temperature loss factor = -4.8%. Production will be 95.2% of STC power.
- Power adjusted for high temperatures = 200 W × .952
- Power adjusted for high temperatures = 190.4 W