  • A minimum of 5% of the C/20 Ah rating is recommended for a system that is used infrequently or is primarily used at night.[1][2]
  • A 10% of the C/20 Ah rating is recommended for a system that is used regularly with significant load usage during the day.
  • A maximum of 13% of the C/20 Ah rating is recommended for gel and flooded lead acid batteries. A maximum of 20% of the C/20 rate Ah rating is recommended for AGM batteries..[1]
  • 1.0 1.1 Cite error: Invalid <ref> tag; no text was provided for refs named trojanpaper