All public logs
Jump to navigation
Jump to search
Combined display of all available logs of Open Source Solar Project. You can narrow down the view by selecting a log type, the username (case-sensitive), or the affected page (also case-sensitive).
(newest | oldest) View (newer 50 | older 50) (20 | 50 | 100 | 250 | 500)- 12:52, 26 November 2020 Alex talk contribs created page Wire sizing and selection (Created page with "Category:Wire sizing and selection Choosing the proper wire size for a circuit is necessary to ensure that the system is safe and functions properly. There are two key con...")
- 12:49, 26 November 2020 Alex talk contribs moved page Component sizing resources to Wire sizing resources without leaving a redirect
- 12:43, 26 November 2020 Alex talk contribs created page Component sizing resources (Created page with "Category:Design resources")
- 12:29, 26 November 2020 Alex talk contribs moved page Overcurrent protection to Overcurrent protection device
- 11:25, 26 November 2020 Alex talk contribs created page File:Inverterprocess.png
- 11:25, 26 November 2020 Alex talk contribs uploaded File:Inverterprocess.png
- 10:38, 26 November 2020 Alex talk contribs created page Category:Inverter sizing and selection (Created blank page)
- 09:26, 26 November 2020 Alex talk contribs created page Inverter sizing and selection (Created page with "Category:Inverter sizing and selection The inverter is sized and selected almost completely based upon the power demands of the user outlined in the Load ev...")
- 15:54, 25 November 2020 Alex talk contribs created page File:PVandCCprocess.png
- 15:54, 25 November 2020 Alex talk contribs uploaded File:PVandCCprocess.png
- 14:25, 25 November 2020 Alex talk contribs deleted page Verifying PV source size (content was: "Category:PV source and charge controller sizing and selection If an off-grid PV system will rely solely upon PV as a charging source (no generator, no other renewables) then it is necessary to to ensure that a PV source is properly sized for this role. There are two checks that should be performed: #The PV source size should be checked to ensure that it can continue to meet the ene...", and the only contributor was "Alex" (talk))
- 09:27, 25 November 2020 Alex talk contribs created page Verifying PV source size (Created page with "Category:PV source and charge controller sizing and selection If an off-grid PV system will rely solely upon PV as a charging source (no generator, no other renewables) th...")
- 09:14, 25 November 2020 Alex talk contribs deleted page Maximum system charging voltage parameter (content was: "The maximum system charging voltage parameter is the value for the maximum voltage at which the energy storage system will be charged. This value is important for PV source and Charge controller|charge controller sizing as the system must be able to supply this voltage under all conditions of use (including in the future as the [[PV module degradation...", and the only contributor was "[[Special:Contributions/Alex|Alex]]" (talk))
- 14:10, 20 November 2020 Alex talk contribs created page PV source and charge controller sizing and selection overiew (Created page with "Category:PV source and charge controller sizing and selection *Flowchart *Emphasize oversizing array. Calculations are the minimum. Need to consider battery bank size, day...")
- 14:04, 20 November 2020 Alex talk contribs created page MPPT charge controller sizing and selection (Created page with "Category:PV source and charge controller sizing and selection")
- 14:01, 20 November 2020 Alex talk contribs moved page PV source sizing to Minimum PV source size
- 14:00, 20 November 2020 Alex talk contribs created page Category:PV source and charge controller sizing and selection (Created blank page)
- 13:58, 20 November 2020 Alex talk contribs created page PWM charge controller sizing and selection (Created page with "Category:PV source and charge controller sizing and selection A PWM charge controller is rated to operate at a particular S...")
- 13:26, 20 November 2020 Alex talk contribs deleted page Charge controller efficiency parameter (content was: "Category:Design parameters PWM charge controllers are more efficient than an MPPT charge controller, nonetheless the design of a MPPT charge controller will lead to it outproducing a PWM charge controller under most conditions - see Charge controller for more info. For design purposes a charge controller type must be selected, but not a make or model. Specifications sheets for...", and the only contributor was "Alex" (talk))
- 13:25, 20 November 2020 Alex talk contribs deleted page PV module degradation parameter (content was: "Category:Design parameters The PV module degradation parameter accounts for the gradual reduction in the performance of PV modules over time. This is a factor that should be taken into account as a PV system should be designed to function for more than a decade. Module degradation not only affects performance, but can lead to a reduction in voltage over time that impe...", and the only contributor was "Alex" (talk))
- 13:25, 20 November 2020 Alex talk contribs moved page PV source and charge controller sizing and selection to PV source sizing
- 12:31, 20 November 2020 Alex talk contribs deleted page Energy storage efficiency parameter (content was: "Category:Design parameters There is no form of energy storage that is 100% efficient, there is always some efficiency loss. It is important to use a conservative value for battery efficiency. *Flooded lead acid (FLA) batteries : 70-80% efficiency<ref name="trojanpaper"> Trojan Battery Company - Selecting the Proper Lead-Acid Techno...", and the only contributor was "Alex" (talk))
- 09:31, 16 November 2020 Alex talk contribs created page Category:PV source and charge controller sizing (Created blank page)
- 09:31, 16 November 2020 Alex talk contribs created page PV source and charge controller sizing and selection (Created page with "Category:PV source and charge controller sizing")
- 18:39, 13 November 2020 Alex talk contribs created page File:Mainflowchart2011131.png
- 18:39, 13 November 2020 Alex talk contribs uploaded File:Mainflowchart2011131.png
- 18:34, 13 November 2020 Alex talk contribs created page File:Energystorageprocess2011132.png
- 18:34, 13 November 2020 Alex talk contribs uploaded File:Energystorageprocess2011132.png
- 18:30, 13 November 2020 Alex talk contribs created page File:Mainflowchart201113.png
- 18:29, 13 November 2020 Alex talk contribs uploaded File:Mainflowchart201113.png
- 18:22, 13 November 2020 Alex talk contribs created page File:Energystorageprocess2011131.png
- 18:22, 13 November 2020 Alex talk contribs uploaded File:Energystorageprocess2011131.png
- 18:13, 13 November 2020 Alex talk contribs created page File:Energystorageprocess201113.png
- 18:13, 13 November 2020 Alex talk contribs uploaded File:Energystorageprocess201113.png
- 17:23, 13 November 2020 Alex talk contribs moved page Overview of energy storage sizing and selection process to Energy storage sizing and selection
- 17:23, 13 November 2020 Alex talk contribs deleted page Energy storage sizing and selection (Deleted to make way for move from "Overview of energy storage sizing and selection process")
- 17:18, 13 November 2020 Alex talk contribs deleted page Days of autonomy parameter (content was: "Category:Design parameters The days of autonomy parameter determines the number of days that the system will be able to meet energy needs without additional charging. 1 day of autonomy provides enough energy storage capacity to provide energy for the loads from the load evaluation without any additional charging. Each additional day adds an additional day of ene...", and the only contributor was "Alex" (talk))
- 17:18, 13 November 2020 Alex talk contribs deleted page Depth of discharge parameter (content was: "Category:Design parameters File:DoDcycles.png|thumb|right|Depth of discharge vs. cycle life for Trojan FLA, AGM and Gel batteries.<ref name="trojanfla"> Trojan Battery Company - Specifications sheet for FLA batteries https://www.trojanbattery.com/pdf/Signature_Trojan_ProductLineSheet.pdf</ref><ref name="trojanagm2"> Trojan Battery Company - Specifications sheet for AGM batteries...", and the only contributor was "Alex" (talk))
- 12:41, 13 November 2020 Alex talk contribs deleted page PV module loss factors (content was: "Category:PV source AHHHHHHHHHHHHHHHH", and the only contributor was "Alex" (talk))
- 12:31, 13 November 2020 Alex talk contribs created page File:Mainflowchartlarge.png
- 12:30, 13 November 2020 Alex talk contribs uploaded File:Mainflowchartlarge.png
- 12:26, 13 November 2020 Alex talk contribs created page File:Energystorageprocess.png
- 12:26, 13 November 2020 Alex talk contribs uploaded File:Energystorageprocess.png
- 11:38, 13 November 2020 Alex talk contribs moved page Overview of energy storage sizing and selection to Overview of energy storage sizing and selection process
- 11:35, 13 November 2020 Alex talk contribs created page Category:Energy storage sizing and selection (Created blank page)
- 11:35, 13 November 2020 Alex talk contribs created page Overview of energy storage sizing and selection (Created page with "Category:Energy storage sizing and selection")
- 10:56, 13 November 2020 Alex talk contribs created page File:DC-DCconnections.png
- 10:56, 13 November 2020 Alex talk contribs uploaded File:DC-DCconnections.png
- 09:57, 13 November 2020 Alex talk contribs created page Maximum system charging voltage parameter (Created page with "The maximum system charging voltage parameter is the value for the maximum voltage at which the energy storage system will be charged. This value is importa...")
- 09:46, 13 November 2020 Alex talk contribs moved page Module degradation parameter to PV module degradation parameter