h English (en) | '''Example 1:''' A PV module is rated at 200W. Cell temperature is measured at 35 °C. The specifications for the module state that it has a TkPmp of -.48 %/°C. What should the power output of the module be? ::::Temperature loss factor = 35°C - 25°C × -.48 %/°C ::::Temperature loss factor = -4.8%. Production will be 95.2% of STC power. ::::Power adjusted for high temperatures = 200 W × .952 ::::Power adjusted for high temperatures = 190.4 W |
h Spanish (es) | '''Ejemplo 1:''' Un módulo FV tiene una potencia nominal de 200W. La temperatura de la celda se mide a 35°C. Las especificaciones del módulo indican que tiene un coeficiente de temperatura de potencia máxima (Tkpmp) de -,48%/°C. ¿Qué debería ser el rendimiento del módulo? :::: Factor de pérdida de temperatura celular = 35°C - 25°C × -,48%/°C :::: Factor de pérdida de temperatura celular = -4,8%. La producción será del 95,2% de la energía STC. :::: Potencia ajustada para altas temperaturas = 200 W × .952 :::: Potencia ajustada para altas temperaturas = 190,4 W |