h English (en) | OCPDs will have a trip curve which specifies how long the device can sustain current above its continuous duty rating. This is desirable because in electrical systems there are often [[Special:MyLanguage/Surge loads|surge loads]] that require additional current for a very brief period of time when starting. If an OCPD does not have a slight time delay, it will trip every time one of these loads starts. For all typical circuits in an off-grid PV system, an OCPD with a time delay is recommended. |
h Spanish (es) | Los OCPD tendrán una curva de disparo que especifica cuánto tiempo el dispositivo puede mantener la corriente por encima de su capacidad de servicio continuo. Esto es deseable porque en los sistemas eléctricos a menudo hay [[Special:MyLanguage/Surge loads|cargas con corrientes de arranque]] que requieren corriente adicional durante un período muy breve al arrancar. Si un DPCS no tiene un ligero retardo de tiempo, se disparará cada vez que arranque una estas cargas. Para todos los circuitos típicos en un sistema FV autónomo, se recomienda un DPCS con un retardo de tiempo. |