 h English (en)*A minimum of 5% of the C/20 Ah rating is recommended for a system that is used infrequently or is primarily used at night.<ref name="trojanpaper"/><ref name="rollspaper"/> 
*A 10% of the C/20 Ah rating is recommended for a system that is used regularly with significant load usage during the day.
*A maximum of 13% of the C/20 Ah rating is recommended for gel and flooded lead acid batteries. A maximum of 20% of the C/20 rate Ah rating is recommended for AGM batteries..<ref name="trojanpaper"/>
 h Spanish (es)*Se recomienda un mínimo del 5% de la clasificación C/20 Ah para un sistema que se usa con poca frecuencia o que se usa principalmente por la noche. <Ref name="trojanpaper"/> <ref name="rollspaper"/>
*Se recomienda un 10% de la clasificación C/20 Ah para un sistema que se usa regularmente con un uso de carga significativo durante el día.
*Se recomienda un máximo del 13% de la clasificación C/20 Ah para baterías de gel y de plomo-ácido inundadas. Se recomienda un máximo del 20% de la clasificación Ah de tasa C / 20 para baterías AGM. <Ref name="trojanpaper"/>