h English (en) | All inverters are rated based upon the amount of power that they can continuously supply in watts or volt-amperes. In addition to this continuous rating an inverter will be able to supply higher amounts of power for brief periods of time in order to supply loads that require momentary surges of more current when starting. These additional ratings may come in 30 minute, 5 minute, 1 minute, 30 second, 10 second or 1 second ratings. All loads and their energy requirements will need to be evaluated to select the appropriate inverter - see [[Special:MyLanguage/Inverter sizing and selection|inverter sizing and selection]] for more information. |
h Spanish (es) | Todos los inversores se clasifican según la potencia que pueden suministrar continuamente en watts o voltios/amperios. Además de esta clasificación de potencia continua, un inversor podrá suministrar mayores cantidades de energía durante breves períodos de tiempo para suministrar cargas que requieran picos momentáneos de más corriente al arrancar. Estas clasificaciones adicionales pueden venir en clasificaciones de 30 minutos, 5 minutos, 1 minuto, 30 segundos, 10 segundos o 1 segundo. Todas las cargas y sus requisitos de energía deberán evaluarse para seleccionar el inversor adecuado; consulte [[Special:MyLanguage/Inverter sizing and selection|Dimensionamiento y selección del inversor]] para obtener más información. |