 h English (en)The DC system voltage chosen for the system will impact the sizing and selection of all other system components. Off-grid PV systems are typically built at several standard voltages - 12 V, 24 V, or 48 V - as all system components must be rated to operate at the same voltage. Each voltage has different advantages and disadvantages that make it appropriate for different system sizes and types. One limitation that is common to all energy storage systems with lead acid batteries is that it is not recommended to incorporate more than 3 parallel strings of batteries as it can create issues during the charging process - see [[Special:MyLanguage/Battery wiring|Battery wiring]]. This constraint often determines the system voltage.
 h Spanish (es)La tensión del sistema de CC elegida para el sistema afectará el tamaño y la selección de todos los demás componentes del sistema. Los sistemas FV autónomos generalmente se construyen con varias tensiones estándares (12 V, 24 V o 48 V), ya que todos los componentes del sistema deben estar clasificados para funcionar con la misma tensión. Cada tensión tiene diferentes ventajas y desventajas que lo hacen apropiado para diferentes tamaños y tipos de sistemas. Una limitación que es común a todos los sistemas de almacenamiento de energía de plomo-ácido es que no se recomienda incorporar más de 3 cadenas paralelas de baterías, ya que puede crear problemas durante el proceso de carga; consulte [[Special:MyLanguage/Battery wiring|Cableado de baterías]]. Esta restricción a menudo determina la tensión del sistema.