Name | Current message text |
---|---|
h English (en) | The [[Special:MyLanguage/Charge controller#Charging phases|absorption phase]] of a charge controller can be set to hold the battery bank at a steady voltage using the minimum amount of current necessary to do so until a set minimum current is reached. The appropriate minimum current depends upon the battery type, the size of the battery bank, and the maximum available charge rate for the system. A manufacturer may give a recommendation in the manual for the particular battery, but often times other sources must be consulted. |
h Spanish (es) | La [[Special:MyLanguage/Charge controller#Charging phases|etapa de absorción]] de un controlador de carga se puede configurar para mantener el sistema de almacenamiento de energía a una tensión constante utilizando la cantidad mínima de corriente necesaria para hacerlo hasta que se alcance una corriente mínima establecida o programada. La corriente mínima apropiada depende del tipo de batería, el tamaño del sistema de almacenamiento de energía y la tasa de carga máxima disponible para el sistema. Un fabricante puede dar una recomendación en el manual para la batería en particular, pero muchas veces es necesario consultar otras fuentes. |