Export translations
Jump to navigation
Jump to search
Settings
Group
About OSSP
Basic stand-alone PV system components
Battery wiring
Busbar
Charge controller
Charge controller programming
Combiner box
Commissioning
Conductor size
Conductor types
Conduit
Continuous duty safety parameter
DC system voltage
DC-DC converter
Design parameter overview
Design process overview
DIN rail
Disconnect
Distribution panel
Duty cycle
Electrical codes
Electrical safety
Electricity and energy
Electricity types
Energy efficient loads
Energy storage
Energy storage sizing and selection
Equipment certification
Equipment clearances and safe working space
Ground fault protection device
Grounding system
Insolation
Installing module connectors
Insulation color
Inverter
Inverter programming
Irradiance safety parameter
Junction box
Labeling
Lead acid battery
Lighting
Lithium-ion battery
Load and solar resource comparison
Load evaluation
Low voltage disconnect
Low voltage disconnect parameter
Main Page
Module connectors
Mounting system types
Multimeters
OSSP stand-alone system design tool
Outlet
Overcurrent protection device
Peru
Physical evaluation
Power factor
Power flow between components
Principles of installation
PV module
PV source and charge controller sizing and selection overview
PV system types
Residual current device
Resources
Series and parallel connections
Shading
Shunt
Simplified energy storage sizing and selection
Simplified load evaluation
Simplified minimum PV source size
Simplified MPPT charge controller sizing and selection
Simplified physical evaluation
Simplified PWM charge controller sizing and selection
Simplified weather and solar resource evaluation
Site evaluation process overview
Stand-alone system configurations
Surge loads
Switch
Tilt and azimuth
Training providers
Troubleshooting
Twist-on wire connector
United States
Voltage and frequency by country
Voltage drop
Weather and solar resource evaluation
Weather rating
What is an off-grid PV system?
Wire terminal
Wiring basic load circuits
Wiring practices
Language
aa - Afar
ab - Abkhazian
abs - Ambonese Malay
ace - Achinese
ady - Adyghe
ady-cyrl - Adyghe (Cyrillic script)
aeb - Tunisian Arabic
aeb-arab - Tunisian Arabic (Arabic script)
aeb-latn - Tunisian Arabic (Latin script)
af - Afrikaans
ak - Akan
aln - Gheg Albanian
am - Amharic
an - Aragonese
ang - Old English
anp - Angika
ar - Arabic
arc - Aramaic
arn - Mapuche
arq - Algerian Arabic
ary - Moroccan Arabic
arz - Egyptian Arabic
as - Assamese
ase - American Sign Language
ast - Asturian
atj - Atikamekw
av - Avaric
avk - Kotava
awa - Awadhi
ay - Aymara
az - Azerbaijani
azb - South Azerbaijani
ba - Bashkir
ban - Balinese
bar - Bavarian
bbc - Batak Toba
bbc-latn - Batak Toba (Latin script)
bcc - Southern Balochi
bcl - Central Bikol
be - Belarusian
be-tarask - Belarusian (Taraškievica orthography)
bg - Bulgarian
bgn - Western Balochi
bh - Bhojpuri
bho - Bhojpuri
bi - Bislama
bjn - Banjar
bm - Bambara
bn - Bangla
bo - Tibetan
bpy - Bishnupriya
bqi - Bakhtiari
br - Breton
brh - Brahui
bs - Bosnian
btm - Batak Mandailing
bto - Iriga Bicolano
bug - Buginese
bxr - Russia Buriat
ca - Catalan
cbk-zam - Chavacano
cdo - Min Dong Chinese
ce - Chechen
ceb - Cebuano
ch - Chamorro
cho - Choctaw
chr - Cherokee
chy - Cheyenne
ckb - Central Kurdish
co - Corsican
cps - Capiznon
cr - Cree
crh - Crimean Turkish
crh-cyrl - Crimean Tatar (Cyrillic script)
crh-latn - Crimean Tatar (Latin script)
cs - Czech
csb - Kashubian
cu - Church Slavic
cv - Chuvash
cy - Welsh
da - Danish
de - German
de-at - Austrian German
de-ch - Swiss High German
de-formal - German (formal address)
din - Dinka
diq - Zazaki
dsb - Lower Sorbian
dtp - Central Dusun
dty - Doteli
dv - Divehi
dz - Dzongkha
ee - Ewe
egl - Emilian
el - Greek
eml - Emiliano-Romagnolo
en - English
en-ca - Canadian English
en-gb - British English
eo - Esperanto
es - Spanish
es-419 - Latin American Spanish
es-formal - español (formal)
et - Estonian
eu - Basque
ext - Extremaduran
fa - Persian
ff - Fulah
fi - Finnish
fit - Tornedalen Finnish
fj - Fijian
fo - Faroese
fr - French
frc - Cajun French
frp - Arpitan
frr - Northern Frisian
fur - Friulian
fy - Western Frisian
ga - Irish
gag - Gagauz
gan - Gan Chinese
gan-hans - Gan (Simplified)
gan-hant - Gan (Traditional)
gcr - Guianan Creole
gd - Scottish Gaelic
gl - Galician
glk - Gilaki
gn - Guarani
gom - Goan Konkani
gom-deva - Goan Konkani (Devanagari script)
gom-latn - Goan Konkani (Latin script)
gor - Gorontalo
got - Gothic
grc - Ancient Greek
gsw - Swiss German
gu - Gujarati
gv - Manx
ha - Hausa
hak - Hakka Chinese
haw - Hawaiian
he - Hebrew
hi - Hindi
hif - Fiji Hindi
hif-latn - Fiji Hindi (Latin script)
hil - Hiligaynon
ho - Hiri Motu
hr - Croatian
hrx - Hunsrik
hsb - Upper Sorbian
ht - Haitian Creole
hu - Hungarian
hu-formal - magyar (formal)
hy - Armenian
hyw - Western Armenian
hz - Herero
ia - Interlingua
id - Indonesian
ie - Interlingue
ig - Igbo
ii - Sichuan Yi
ik - Inupiaq
ike-cans - Eastern Canadian (Aboriginal syllabics)
ike-latn - Eastern Canadian (Latin script)
ilo - Iloko
inh - Ingush
io - Ido
is - Icelandic
it - Italian
iu - Inuktitut
ja - Japanese
jam - Jamaican Creole English
jbo - Lojban
jut - Jutish
jv - Javanese
ka - Georgian
kaa - Kara-Kalpak
kab - Kabyle
kbd - Kabardian
kbd-cyrl - Kabardian (Cyrillic script)
kbp - Kabiye
kg - Kongo
khw - Khowar
ki - Kikuyu
kiu - Kirmanjki
kj - Kuanyama
kjp - Eastern Pwo
kk - Kazakh
kk-arab - Kazakh (Arabic script)
kk-cn - Kazakh (China)
kk-cyrl - Kazakh (Cyrillic script)
kk-kz - Kazakh (Kazakhstan)
kk-latn - Kazakh (Latin script)
kk-tr - Kazakh (Turkey)
kl - Kalaallisut
km - Khmer
kn - Kannada
ko - Korean
ko-kp - Korean (North Korea)
koi - Komi-Permyak
kr - Kanuri
krc - Karachay-Balkar
kri - Krio
krj - Kinaray-a
krl - Karelian
ks - Kashmiri
ks-arab - Kashmiri (Arabic script)
ks-deva - Kashmiri (Devanagari script)
ksh - Colognian
ku - Kurdish
ku-arab - Kurdish (Arabic script)
ku-latn - Kurdish (Latin script)
kum - Kumyk
kv - Komi
kw - Cornish
ky - Kyrgyz
la - Latin
lad - Ladino
lb - Luxembourgish
lbe - Lak
lez - Lezghian
lfn - Lingua Franca Nova
lg - Ganda
li - Limburgish
lij - Ligurian
liv - Livonian
lki - Laki
lmo - Lombard
ln - Lingala
lo - Lao
loz - Lozi
lrc - Northern Luri
lt - Lithuanian
ltg - Latgalian
lus - Mizo
luz - Southern Luri
lv - Latvian
lzh - Literary Chinese
lzz - Laz
mai - Maithili
map-bms - Basa Banyumasan
mdf - Moksha
mg - Malagasy
mh - Marshallese
mhr - Eastern Mari
mi - Maori
min - Minangkabau
mk - Macedonian
ml - Malayalam
mn - Mongolian
mni - Manipuri
mnw - Mon
mo - Moldovan
mr - Marathi
mrj - Western Mari
ms - Malay
mt - Maltese
mus - Muscogee
mwl - Mirandese
my - Burmese
myv - Erzya
mzn - Mazanderani
na - Nauru
nah - Nāhuatl
nan - Min Nan Chinese
nap - Neapolitan
nb - Norwegian Bokmål
nds - Low German
nds-nl - Low Saxon
ne - Nepali
new - Newari
ng - Ndonga
niu - Niuean
nl - Dutch
nl-informal - Nederlands (informeel)
nn - Norwegian Nynorsk
no - Norwegian
nov - Novial
nqo - N’Ko
nrm - Norman
nso - Northern Sotho
nv - Navajo
ny - Nyanja
nys - Nyungar
oc - Occitan
olo - Livvi-Karelian
om - Oromo
or - Odia
os - Ossetic
pa - Punjabi
pag - Pangasinan
pam - Pampanga
pap - Papiamento
pcd - Picard
pdc - Pennsylvania German
pdt - Plautdietsch
pfl - Palatine German
pi - Pali
pih - Norfuk / Pitkern
pl - Polish
pms - Piedmontese
pnb - Western Punjabi
pnt - Pontic
prg - Prussian
ps - Pashto
pt - Portuguese
pt-br - Brazilian Portuguese
qqq - Message documentation
qu - Quechua
qug - Chimborazo Highland Quichua
rgn - Romagnol
rif - Riffian
rm - Romansh
rmy - Vlax Romani
rn - Rundi
ro - Romanian
roa-tara - Tarantino
ru - Russian
rue - Rusyn
rup - Aromanian
ruq - Megleno-Romanian
ruq-cyrl - Megleno-Romanian (Cyrillic script)
ruq-latn - Megleno-Romanian (Latin script)
rw - Kinyarwanda
sa - Sanskrit
sah - Sakha
sat - Santali
sc - Sardinian
scn - Sicilian
sco - Scots
sd - Sindhi
sdc - Sassarese Sardinian
sdh - Southern Kurdish
se - Northern Sami
sei - Seri
ses - Koyraboro Senni
sg - Sango
sgs - Samogitian
sh - Serbo-Croatian
shi - Tachelhit
shi-latn - Tachelhit (Latin script)
shi-tfng - Tachelhit (Tifinagh script)
shn - Shan
shy-latn - Shawiya (Latin script)
si - Sinhala
simple - Simple English
sk - Slovak
skr - Saraiki
skr-arab - Saraiki (Arabic script)
sl - Slovenian
sli - Lower Silesian
sm - Samoan
sma - Southern Sami
sn - Shona
so - Somali
sq - Albanian
sr - Serbian
sr-ec - Serbian (Cyrillic script)
sr-el - Serbian (Latin script)
srn - Sranan Tongo
ss - Swati
st - Southern Sotho
stq - Saterland Frisian
sty - cебертатар
su - Sundanese
sv - Swedish
sw - Swahili
szl - Silesian
ta - Tamil
tay - Tayal
tcy - Tulu
te - Telugu
tet - Tetum
tg - Tajik
tg-cyrl - Tajik (Cyrillic script)
tg-latn - Tajik (Latin script)
th - Thai
ti - Tigrinya
tk - Turkmen
tl - Tagalog
tly - Talysh
tn - Tswana
to - Tongan
tpi - Tok Pisin
tr - Turkish
tru - Turoyo
ts - Tsonga
tt - Tatar
tt-cyrl - Tatar (Cyrillic script)
tt-latn - Tatar (Latin script)
tum - Tumbuka
tw - Twi
ty - Tahitian
tyv - Tuvinian
tzm - Central Atlas Tamazight
udm - Udmurt
ug - Uyghur
ug-arab - Uyghur (Arabic script)
ug-latn - Uyghur (Latin script)
uk - Ukrainian
ur - Urdu
uz - Uzbek
uz-cyrl - Uzbek (Cyrillic script)
uz-latn - Uzbek (Latin script)
ve - Venda
vec - Venetian
vep - Veps
vi - Vietnamese
vls - West Flemish
vmf - Main-Franconian
vo - Volapük
vot - Votic
vro - Võro
wa - Walloon
war - Waray
wo - Wolof
wuu - Wu Chinese
xal - Kalmyk
xh - Xhosa
xmf - Mingrelian
xsy - Saisiyat
yi - Yiddish
yo - Yoruba
yue - Cantonese
za - Zhuang
zea - Zeelandic
zgh - Standard Moroccan Tamazight
zh - Chinese
zh-cn - Chinese (China)
zh-hans - Simplified Chinese
zh-hant - Traditional Chinese
zh-hk - Chinese (Hong Kong)
zh-mo - Chinese (Macau)
zh-my - Chinese (Malaysia)
zh-sg - Chinese (Singapore)
zh-tw - Chinese (Taiwan)
zu - Zulu
Format
Export for off-line translation
Export in native format
Fetch
[[Category:PV source]] <languages /> [[File:Modulecrosssection201026.png|thumb|right|250px|'''Components of a PV module:'''<br />''(1)'' Aluminum frame ''(2)'' Glass ''(3)'' Encapsulant (hold cells together) ''(4)'' Cells ''(5)'' Encapsulant (hold cells together) ''(6)'' Plastic backsheet ''(7)'' Module frame ''(8)'' Junction box with wires/connectors]] [[File:Solarcellv22102101.png|thumb|right|250px|A circuit attached to a PV cell. Electrons are energized by the sun (via photons). There is a one-way barrier the cell (depicted in red) that only allows the electrons to move in one direction. As they begin to concentrate on Side 1 of the cell are forced through the circuit.]] Solar photovoltaic (PV) modules use the photovoltaic (PV) effect to generate electrical current upon exposure to light. When sufficient light hits a PV cell, current is generated which excites electrons that then pass through a one-way barrier or junction forcing them to flow through a circuit to return to their point of origin. These movement of these electrons can be used to do work or power loads. There are many different technologies available and ways to design a system that can meet needs that range from simple lighting, to running appliances, pumping water or powering cities. PV modules are composed of individual cells wired together in [[Special:MyLanguage/Series and parallel connections|series]] with each one producing around.5 V when exposed to sufficient light. PV modules come in several common configurations: *A 36-cell module comprised of .5 V cells will have a voltage at maximum power (Vmp) of around 18 V. *A 60-cell module comprised of .5 V cells will have a voltage at maximum power (Vmp) of around 30 V. *A 72-cell module comprised of .5 V cells will have a voltage at maximum power (Vmp) of around 36 V. The PV source for an off-grid system - the PV module(s) or array - must be sized and selected in conjunction with the charge controller - see [[Special:MyLanguage/PV source and charge controller sizing and selection overview|PV source and charge controller sizing and selection overview]] for more information. == Types == [[File:Modules201007.png|thumb|250px|''Left -'' Back of a PV module with specifications, junction box and wiring.<br />''Center -'' 60-cell polycrystalline module with cell below.<br />''Right -'' 60-cell monocrystalline module with cell below.]] There are many different chemistries that are used in PV cells, but there are two main categories of modules that are found on the market. Each type of PV module continues to have different characteristics that can be attractive depending upon the circumstances such as lower price or higher efficiency. PV modules are rated in terms of efficiency at total conversion of light into usable electricity - a measurement that has slowly been increasing for all module types over the years. In simplest terms, a module that is 20% efficient is able to convert 20% of all the light that hits it into usable electricity. Increasing efficiency by 3% - from 17% to 20% - may not sound like much, but it will result in a 17.6% increase in production from the PV module (3% ÷ 17% × 100 = 17.6%). ===Crystalline silicon modules=== The most common type of module on the market. These modules can come in poly or monocrystalline construction. The names are derived from the way that they are manufactured with monocrystalline cells being cut from a single crystal and polycrystalline cells being comprised of silicon from various crystals. Both types are composed of a few simple materials (average by weight): 76% glass (panel surface), 10% polymer (encapsulant and backsheet foil), 8% aluminum (mostly the frame), 5% silicon (PV cells), 1% copper (interconnectors) and less than 0.1% silver (contact lines) and other metals (mostly tin and lead).<ref name="irena"> IRENA End-of-Life Management Solar Photovoltaic Panels. https://www.irena.org/-/media/Files/IRENA/Agency/Publication/2016/IRENA_IEAPVPS_End-of-Life_Solar_PV_Panels_2016.pdf </ref> *Monocrystalline modules are more expensive, but achieve higher average efficiencies around 17-20%. *Polycrystalline modules are less expensive and are less efficient with average efficiencies around 16-17%. ====Variants of crystalline silicon modules==== *PERC (passivated emitter and rear contact or rear cell) modules have an extra layer that increases efficiency to around 21%. The manufacturing process is more complicated so they are more expensive than basic modules. *Bi-facial modules have a different design and lack the white polymer (plastic) backsheet that most PV modules have to allow them to absorb more sunlight from their backside. For installations like [[Special:MyLanguage/Mounting system types|ground mount systems and pole mount systems]], where the back of the PV module is exposed to light that may be reflection from the ground or other surfaces, this can increase production from between 5% and 30%. The manufacturing process is more complicated so they are more expensive than basic modules. ===Thin film modules=== Thin film modules are built out by laying photovoltaic material in one or more layers on a supporting material such as glass, plastic, or metal. Thin film modules come in various types with Cadmium-Telluride (CdTe) Being the most common. CdTe modules contain far less aluminum and more glass than Crystalline silicon modules (average by weight): 97% glass (panel surface), ~3% polymer (junction boxes and sealant) and negligible amounts of semiconductors and metals. <ref name="irena" /> Thin film modules are far less efficient than crystalline silicon modules at around 9% efficiency, but significantly cheaper.</ol> ==Standard test conditions== [[File:Modulespeclabel -200921-2.png|thumb|right|250px|Typical specifications label found on the back of a PV module.]] PV modules are rated in terms of watts (W) under industry determined laboratory test conditions called standard test conditions (STC). The three conditions are: the strength of sunlight called irradiance, the temperature of the PV module cells, and the airmass. Airmass is fixed for a given location, so it plays a less important role than the other two. PV modules will only produce their rated power at their Maximum Power Point, which is Vmp multiplied by Imp, under standard test conditions laboratory. These conditions are not frequently reached in most locations as cell temperatures rise quickly when exposed to sunlight and irradiance of 1000 W/m² only occurs when the sky is clear near midday. Therefore, the curve shown the preceding graphics will shift depending upon the conditions. A PV module is tested and rated based upon the following values which can be found printed on the module or in its specifications sheet: *Open circuit voltage (Voc) – The voltage that the module will produce under STC when it is in an [[Special:MyLanguage/Electricity and energy#Circuits|open circuit]] (disconnected, no current flow). *Short circuit current (Isc) – The current that a module will produce under STC when it is [[Special:MyLanguage/Electricity and energy#Circuits|short-circuited]]. (All available curent flowing with minimal resistance, for example when the positive output of a PV module is connected directly connected to its negative). *Maximum power voltage (Vmp) – The voltage that the module will produce when connected to a circuit under STC. *Maximum power current (Imp) – The current that the module will produce when connected to a circuit under STC. *Temperature coefficient of power (Tkpmp) - A coefficient that accounts for how module power responds to increases and decreases in temperature in %/°C or V/°C. *Temperature coefficient of open circuit voltage (Tkvoc) - A coefficient that accounts for how module voltage responds to increases and decreases in temperature in %/°C or V/°C. ===Irradiance=== [[File:Irradiance - 200921-2.png|thumb|250px|I-V curve of a PV module as irradiance decreases. Each 25% drop in irradiance accounts for roughly a 25% drop in current and production.]] Irradiance is a measurement of sunlight intensity (power) that constantly varies throughout the day naturally as the sun moves through the sky, but also due to weather. Irradiance measured over time is referred to as [[Special:MyLanguage/Insolation|insolation]] and is vitally important for measuring PV system production over time. On a clear day irradiance typically will reach its peak around noon. 1000 W/m² is an irradiance value for a clear day around noon, which means that it is not likely to be normal operating condition in most locations. Irradiance can only be measured with specialized and sensitive equipment, but it can be estimated as irradiance has a direct relationship with the current and power that the module outputs. PV module are given their power ratings by testing them at 1000 W/m² of irradiance. Irradiance below 1000 W/m² ''reduces'' cell current and irradiance above 1000 W/m² ''increases'' cell current. Irradiance can increase beyond 1000 W/m² under certain geographic and meteorological conditions. The formula for calculating production based upon irradiance is: {| class="wikitable" border=1 style="width: 60%;" ! style="width: 30%"|Irradiance loss factor ! style="text-align:left;"| = measured W/m² ÷ 1000 W/m² |} '''Example 1:''' A PV module is rated at 200 W. Irradiance is measured at 750 W/m² and the temperature of the PV module is measured at 25°C. What should the power output of the module be? ::::Irradiance loss factor = 750 W/m² ÷ 1000 W/m² = .75 ::::Power adjusted for decreased irradiance = 200 W × .75 ::::Power adjusted for decreased irradiance = 150 W ===Cell temperature=== [[File:Temperature - 200921.png|thumb|250px|A diagram of the I-V curve of a PV module as the temperature fluctuates.]] Cell temperature is the no more complicated than it sounds - the temperature of the PV cells. Cell temperature can be easily measured and has a direct relationship with voltage. Cell temperatures above 25°C ''decrease'' cell voltage and cell temperatures above 25°C ''increase'' cell voltage. If cell temperatures are below 25°C, it is possible for a to exceed the module's rated Open Circuit Voltage (Voc). Losses due to increased cell temperature greatly decrease PV cell production in all PV installations at some moment. The formula for calculating losses due to increased cell temperatures is: {| class="wikitable" border=1 style="width: 60%;" ! style="width: 30%"|Temperature loss factor ! style="text-align:left;"| = measured cell temperature - 25°C × temperature coefficient of max power (TkPmp) |} :*TkPmp is a value from the module specifications sheet and is typically in the form of %/°C. '''Example 1:''' A PV module is rated at 200W. Cell temperature is measured at 35 °C. The specifications for the module state that it has a TkPmp of -.48 %/°C. What should the power output of the module be? ::::Temperature loss factor = 35°C - 25°C × -.48 %/°C ::::Temperature loss factor = -4.8%. Production will be 95.2% of STC power. ::::Power adjusted for high temperatures = 200 W × .952 ::::Power adjusted for high temperatures = 190.4 W ===Air mass=== Air mass is a measurement of the amount of the atmosphere that light from the sun has to pass through before reaching the PV module. It does vary globally, but it isn't relevant here as it isn't a factor that significantly varies for a given location from year to year. ==Projected life== A well-made silicon PV module will continue functioning over 25 years, although all modules degrade with the passage of time. High-quality modules degrade at an average rate of .5% to 1% per year, whereas poorly made modules degrade even quicker. This is the primary difference between the different costs and qualities of modules. ==Maintenance== PV modules are built out of durable materials and have no moving parts. The only maintenance that is likely to ever be required a module is an occasionally cleaning if the module is in an area that lacks regular rainfall. ==Recyclability== The waste classifications of PV modules varies by location significantly, but regardless of location they should be treated as specialized waste and should not be discarded with normal trash. The process for recycling a PV module consists of breaking it down into its main components and then sending them through the appropriate recycling streams. Unfortunately, in many areas where PV is being used to facilitate energy access, there are insufficient regulations and therefore a complete lack of a market and infrastructure to handle PV module waste. *The majority of PV modules installed globally are crystalline silicon (c-Si modules) which are on average comprised of roughly 90% non-hazardous materials by mass<ref name="irena" /> - glass, aluminium, and polymer - that are recycle or disposed of relatively easy. Roughly 85% of a module can be recycled<ref name="irena" />. The issue is the other 10% of a PV module that includes the PV cells which may contain silver, tin, lead and other elements<ref name="irena" />. Properly recycling these parts of the module require specialized handling and processes. *Thin-film modules represent a smaller portion of the PV modules used in installations globally and consist of roughly 98% non-hazardous materials like glass, polymer, aluminium, and copper. Unfortunately, the other 2% of thin-film modules contain various hazardous materials such as indium, gallium, selenium, cadmium tellurium and lead<ref name="irena" />. Properly recycling these parts of the module require specialized handling and processes. == Notes/references == <references/>
Navigation menu
Personal tools
English
Create account
Log in
Namespaces
Special page
Variants
Views
More
Search
Navigation
Main page
Recent changes
Random page
Help about MediaWiki
Tools
Special pages
Printable version