Export translations
Jump to navigation
Jump to search
Settings
Group
About OSSP
Basic stand-alone PV system components
Battery wiring
Busbar
Charge controller
Charge controller programming
Combiner box
Commissioning
Conductor size
Conductor types
Conduit
Continuous duty safety parameter
DC system voltage
DC-DC converter
Design parameter overview
Design process overview
DIN rail
Disconnect
Distribution panel
Duty cycle
Electrical codes
Electrical safety
Electricity and energy
Electricity types
Energy efficient loads
Energy storage
Energy storage sizing and selection
Equipment certification
Equipment clearances and safe working space
Ground fault protection device
Grounding system
Insolation
Installing module connectors
Insulation color
Inverter
Inverter programming
Irradiance safety parameter
Junction box
Labeling
Lead acid battery
Lighting
Lithium-ion battery
Load and solar resource comparison
Load evaluation
Low voltage disconnect
Low voltage disconnect parameter
Main Page
Module connectors
Mounting system types
Multimeters
OSSP stand-alone system design tool
Outlet
Overcurrent protection device
Peru
Physical evaluation
Power factor
Power flow between components
Principles of installation
PV module
PV source and charge controller sizing and selection overview
PV system types
Residual current device
Resources
Series and parallel connections
Shading
Shunt
Simplified energy storage sizing and selection
Simplified load evaluation
Simplified minimum PV source size
Simplified MPPT charge controller sizing and selection
Simplified physical evaluation
Simplified PWM charge controller sizing and selection
Simplified weather and solar resource evaluation
Site evaluation process overview
Stand-alone system configurations
Surge loads
Switch
Tilt and azimuth
Training providers
Troubleshooting
Twist-on wire connector
United States
Voltage and frequency by country
Voltage drop
Weather and solar resource evaluation
Weather rating
What is an off-grid PV system?
Wire terminal
Wiring basic load circuits
Wiring practices
Language
aa - Afar
ab - Abkhazian
abs - Ambonese Malay
ace - Achinese
ady - Adyghe
ady-cyrl - Adyghe (Cyrillic script)
aeb - Tunisian Arabic
aeb-arab - Tunisian Arabic (Arabic script)
aeb-latn - Tunisian Arabic (Latin script)
af - Afrikaans
ak - Akan
aln - Gheg Albanian
am - Amharic
an - Aragonese
ang - Old English
anp - Angika
ar - Arabic
arc - Aramaic
arn - Mapuche
arq - Algerian Arabic
ary - Moroccan Arabic
arz - Egyptian Arabic
as - Assamese
ase - American Sign Language
ast - Asturian
atj - Atikamekw
av - Avaric
avk - Kotava
awa - Awadhi
ay - Aymara
az - Azerbaijani
azb - South Azerbaijani
ba - Bashkir
ban - Balinese
bar - Bavarian
bbc - Batak Toba
bbc-latn - Batak Toba (Latin script)
bcc - Southern Balochi
bcl - Central Bikol
be - Belarusian
be-tarask - Belarusian (Taraškievica orthography)
bg - Bulgarian
bgn - Western Balochi
bh - Bhojpuri
bho - Bhojpuri
bi - Bislama
bjn - Banjar
bm - Bambara
bn - Bangla
bo - Tibetan
bpy - Bishnupriya
bqi - Bakhtiari
br - Breton
brh - Brahui
bs - Bosnian
btm - Batak Mandailing
bto - Iriga Bicolano
bug - Buginese
bxr - Russia Buriat
ca - Catalan
cbk-zam - Chavacano
cdo - Min Dong Chinese
ce - Chechen
ceb - Cebuano
ch - Chamorro
cho - Choctaw
chr - Cherokee
chy - Cheyenne
ckb - Central Kurdish
co - Corsican
cps - Capiznon
cr - Cree
crh - Crimean Turkish
crh-cyrl - Crimean Tatar (Cyrillic script)
crh-latn - Crimean Tatar (Latin script)
cs - Czech
csb - Kashubian
cu - Church Slavic
cv - Chuvash
cy - Welsh
da - Danish
de - German
de-at - Austrian German
de-ch - Swiss High German
de-formal - German (formal address)
din - Dinka
diq - Zazaki
dsb - Lower Sorbian
dtp - Central Dusun
dty - Doteli
dv - Divehi
dz - Dzongkha
ee - Ewe
egl - Emilian
el - Greek
eml - Emiliano-Romagnolo
en - English
en-ca - Canadian English
en-gb - British English
eo - Esperanto
es - Spanish
es-419 - Latin American Spanish
es-formal - español (formal)
et - Estonian
eu - Basque
ext - Extremaduran
fa - Persian
ff - Fulah
fi - Finnish
fit - Tornedalen Finnish
fj - Fijian
fo - Faroese
fr - French
frc - Cajun French
frp - Arpitan
frr - Northern Frisian
fur - Friulian
fy - Western Frisian
ga - Irish
gag - Gagauz
gan - Gan Chinese
gan-hans - Gan (Simplified)
gan-hant - Gan (Traditional)
gcr - Guianan Creole
gd - Scottish Gaelic
gl - Galician
glk - Gilaki
gn - Guarani
gom - Goan Konkani
gom-deva - Goan Konkani (Devanagari script)
gom-latn - Goan Konkani (Latin script)
gor - Gorontalo
got - Gothic
grc - Ancient Greek
gsw - Swiss German
gu - Gujarati
gv - Manx
ha - Hausa
hak - Hakka Chinese
haw - Hawaiian
he - Hebrew
hi - Hindi
hif - Fiji Hindi
hif-latn - Fiji Hindi (Latin script)
hil - Hiligaynon
ho - Hiri Motu
hr - Croatian
hrx - Hunsrik
hsb - Upper Sorbian
ht - Haitian Creole
hu - Hungarian
hu-formal - magyar (formal)
hy - Armenian
hyw - Western Armenian
hz - Herero
ia - Interlingua
id - Indonesian
ie - Interlingue
ig - Igbo
ii - Sichuan Yi
ik - Inupiaq
ike-cans - Eastern Canadian (Aboriginal syllabics)
ike-latn - Eastern Canadian (Latin script)
ilo - Iloko
inh - Ingush
io - Ido
is - Icelandic
it - Italian
iu - Inuktitut
ja - Japanese
jam - Jamaican Creole English
jbo - Lojban
jut - Jutish
jv - Javanese
ka - Georgian
kaa - Kara-Kalpak
kab - Kabyle
kbd - Kabardian
kbd-cyrl - Kabardian (Cyrillic script)
kbp - Kabiye
kg - Kongo
khw - Khowar
ki - Kikuyu
kiu - Kirmanjki
kj - Kuanyama
kjp - Eastern Pwo
kk - Kazakh
kk-arab - Kazakh (Arabic script)
kk-cn - Kazakh (China)
kk-cyrl - Kazakh (Cyrillic script)
kk-kz - Kazakh (Kazakhstan)
kk-latn - Kazakh (Latin script)
kk-tr - Kazakh (Turkey)
kl - Kalaallisut
km - Khmer
kn - Kannada
ko - Korean
ko-kp - Korean (North Korea)
koi - Komi-Permyak
kr - Kanuri
krc - Karachay-Balkar
kri - Krio
krj - Kinaray-a
krl - Karelian
ks - Kashmiri
ks-arab - Kashmiri (Arabic script)
ks-deva - Kashmiri (Devanagari script)
ksh - Colognian
ku - Kurdish
ku-arab - Kurdish (Arabic script)
ku-latn - Kurdish (Latin script)
kum - Kumyk
kv - Komi
kw - Cornish
ky - Kyrgyz
la - Latin
lad - Ladino
lb - Luxembourgish
lbe - Lak
lez - Lezghian
lfn - Lingua Franca Nova
lg - Ganda
li - Limburgish
lij - Ligurian
liv - Livonian
lki - Laki
lmo - Lombard
ln - Lingala
lo - Lao
loz - Lozi
lrc - Northern Luri
lt - Lithuanian
ltg - Latgalian
lus - Mizo
luz - Southern Luri
lv - Latvian
lzh - Literary Chinese
lzz - Laz
mai - Maithili
map-bms - Basa Banyumasan
mdf - Moksha
mg - Malagasy
mh - Marshallese
mhr - Eastern Mari
mi - Maori
min - Minangkabau
mk - Macedonian
ml - Malayalam
mn - Mongolian
mni - Manipuri
mnw - Mon
mo - Moldovan
mr - Marathi
mrj - Western Mari
ms - Malay
mt - Maltese
mus - Muscogee
mwl - Mirandese
my - Burmese
myv - Erzya
mzn - Mazanderani
na - Nauru
nah - Nāhuatl
nan - Min Nan Chinese
nap - Neapolitan
nb - Norwegian Bokmål
nds - Low German
nds-nl - Low Saxon
ne - Nepali
new - Newari
ng - Ndonga
niu - Niuean
nl - Dutch
nl-informal - Nederlands (informeel)
nn - Norwegian Nynorsk
no - Norwegian
nov - Novial
nqo - N’Ko
nrm - Norman
nso - Northern Sotho
nv - Navajo
ny - Nyanja
nys - Nyungar
oc - Occitan
olo - Livvi-Karelian
om - Oromo
or - Odia
os - Ossetic
pa - Punjabi
pag - Pangasinan
pam - Pampanga
pap - Papiamento
pcd - Picard
pdc - Pennsylvania German
pdt - Plautdietsch
pfl - Palatine German
pi - Pali
pih - Norfuk / Pitkern
pl - Polish
pms - Piedmontese
pnb - Western Punjabi
pnt - Pontic
prg - Prussian
ps - Pashto
pt - Portuguese
pt-br - Brazilian Portuguese
qqq - Message documentation
qu - Quechua
qug - Chimborazo Highland Quichua
rgn - Romagnol
rif - Riffian
rm - Romansh
rmy - Vlax Romani
rn - Rundi
ro - Romanian
roa-tara - Tarantino
ru - Russian
rue - Rusyn
rup - Aromanian
ruq - Megleno-Romanian
ruq-cyrl - Megleno-Romanian (Cyrillic script)
ruq-latn - Megleno-Romanian (Latin script)
rw - Kinyarwanda
sa - Sanskrit
sah - Sakha
sat - Santali
sc - Sardinian
scn - Sicilian
sco - Scots
sd - Sindhi
sdc - Sassarese Sardinian
sdh - Southern Kurdish
se - Northern Sami
sei - Seri
ses - Koyraboro Senni
sg - Sango
sgs - Samogitian
sh - Serbo-Croatian
shi - Tachelhit
shi-latn - Tachelhit (Latin script)
shi-tfng - Tachelhit (Tifinagh script)
shn - Shan
shy-latn - Shawiya (Latin script)
si - Sinhala
simple - Simple English
sk - Slovak
skr - Saraiki
skr-arab - Saraiki (Arabic script)
sl - Slovenian
sli - Lower Silesian
sm - Samoan
sma - Southern Sami
sn - Shona
so - Somali
sq - Albanian
sr - Serbian
sr-ec - Serbian (Cyrillic script)
sr-el - Serbian (Latin script)
srn - Sranan Tongo
ss - Swati
st - Southern Sotho
stq - Saterland Frisian
sty - cебертатар
su - Sundanese
sv - Swedish
sw - Swahili
szl - Silesian
ta - Tamil
tay - Tayal
tcy - Tulu
te - Telugu
tet - Tetum
tg - Tajik
tg-cyrl - Tajik (Cyrillic script)
tg-latn - Tajik (Latin script)
th - Thai
ti - Tigrinya
tk - Turkmen
tl - Tagalog
tly - Talysh
tn - Tswana
to - Tongan
tpi - Tok Pisin
tr - Turkish
tru - Turoyo
ts - Tsonga
tt - Tatar
tt-cyrl - Tatar (Cyrillic script)
tt-latn - Tatar (Latin script)
tum - Tumbuka
tw - Twi
ty - Tahitian
tyv - Tuvinian
tzm - Central Atlas Tamazight
udm - Udmurt
ug - Uyghur
ug-arab - Uyghur (Arabic script)
ug-latn - Uyghur (Latin script)
uk - Ukrainian
ur - Urdu
uz - Uzbek
uz-cyrl - Uzbek (Cyrillic script)
uz-latn - Uzbek (Latin script)
ve - Venda
vec - Venetian
vep - Veps
vi - Vietnamese
vls - West Flemish
vmf - Main-Franconian
vo - Volapük
vot - Votic
vro - Võro
wa - Walloon
war - Waray
wo - Wolof
wuu - Wu Chinese
xal - Kalmyk
xh - Xhosa
xmf - Mingrelian
xsy - Saisiyat
yi - Yiddish
yo - Yoruba
yue - Cantonese
za - Zhuang
zea - Zeelandic
zgh - Standard Moroccan Tamazight
zh - Chinese
zh-cn - Chinese (China)
zh-hans - Simplified Chinese
zh-hant - Traditional Chinese
zh-hk - Chinese (Hong Kong)
zh-mo - Chinese (Macau)
zh-my - Chinese (Malaysia)
zh-sg - Chinese (Singapore)
zh-tw - Chinese (Taiwan)
zu - Zulu
Format
Export for off-line translation
Export in native format
Fetch
{{DISPLAYTITLE:Dispositivo de protección contra sobrecorriente}}[[Category:Protection devices and disconnects]] <languages /> [[File:Fusebreaker201021.png|thumb|right|'''Ejemplos de Dispositivo de protección contra sobrecorriente'''<br/>''(1)'' Interruptor automático ''(2)'' Fusible]] Todos los componentes de un sistema eléctrico tienen una cantidad máxima de corriente que están clasificados para manejar de manera continua, si se excede esta clasificación, se generará un exceso de calor que puede provocar un incendio. Los dispositivos de protección contra sobrecorriente (DPCS) se utilizan para [[Special:MyLanguage/ Electricity and energy#Circuits|abrir]] (desconectar) automáticamente un circuito si se alcanza una determinada corriente durante un cierto período de tiempo. El tamaño del dispositivo de protección contra sobrecorrientes requerido está determinado por la cantidad máxima de corriente que se anticipa que transportará un circuito y el tamaño del conductor en el circuito que está protegiendo. Los tipos más comunes de dispositivos de protección contra sobrecorriente que se utilizan en los sistemas eléctricos son los fusibles y los interruptores automáticos. Los DPCS para un sistema FV autónomo deben dimensionarse y seleccionarse junto con el [[Special:MyLanguage/Conductor size|tamaño del conductor]] de un circuito; consulte [[Special:MyLanguage/Wire, overcurrent protection, and disconnect sizing and selection|Dimensionamiento y selección de cables, protección contra sobrecorrientes y medios de desconexión]] para obtener más información. ==DPCS en un sistema FV autónomo== [[File:breakerslabeled201201.png|thumb|right|Diagrama de cableado de un sistema FV autónomo con un controlador de carga con control de iluminación de CC y un inversor para cargas de CA. Se identifican todos los posibles DPCS, pero es posible que no todos sean necesarios.]] Cada sistema FV variará en términos de sus necesidades de DPCS debido al diseño y los requisitos locales. El diagrama de la derecha muestra un hipotético sistema autónomo con iluminación de CC y un inversor para cargas CA. El gráfico muestra todos los DPCS que se incorporan comúnmente en un sistema autónomo, pero los sistemas más simples no requerirán tantos y los sistemas más complejos probablemente requerirán OCPD adicionales. No todos los OCPD en el diagrama son completamente necesarios, es posible omitir algunos, ya que ya están protegidos de una corriente excesiva por otro DPCS. Cualquier conexión realizada directamente al [[Special:MyLanguage/Energy storage|sistema de almacenamiento de energía]] debe estar protegida por un DPCS ya que el [[Special: MyLanguage/Energy storage|sistema de almacenamiento de energía]] puede suministrar una enorme cantidad de corriente en un corto período de tiempo. Muchos de los DCPS representados en el gráfico también sirven como [[Special:MyLanguage/Disconnect|medios de desconexion de fuente de energía]] y [[Special:MyLanguage/Disconnect|medios de desconexion de equipos]]. #Circuito de fuente PV DPCS #Circuito de salida PV DPCS #Circuito de salida del controlador de carga DPCS #Circuito de salida de iluminación de CC DPCS #Circuito derivado de CC DPCS #Circuito de entrada del inversor DPCS #Circuito de salida del inversor DPCS #Circuito derivado CA DPCS #Circuito de batería DPCS ==Caracteristicas== Hay muchos tipos de DPCS en el mercado y cada uno está diseñado para un uso en específico. Muchos DPCS son similares en apariencia, por lo que es muy importante revisar la letra pequeña en el lateral de cualquier OCPD que se esté considerando para asegurarse de que sea apropiado para las condiciones de uso. ====Tipo de corriente==== Los DPCS pueden diseñarse para funcionar con CA, CC o ambos tipos de corriente. Si un interruptor autómatico es clasificado para CA y CC, es probable que la tensión de CC sea menor ya que los circuitos de CC son más difíciles de abirir o interrumpir. ====Corriente máxima==== [[File:Tripcurve.png|thumb|right|'''El gráfico muestra varios modelos de un interruptor autómatico con la misma corriente máxima, pero con diferentes curvas de disparo:''' <br /> ''(B)'' (más sensible), ''(C)'' (un poquito menos sensible), ''(D)'' (lo más sensible).<ref name="tripcurves"> Wikimedia Commons: Standard Trip Characteristic of a Thermomagnetic Circuit Breaker https://commons.wikimedia.org/wiki/File:Standard_Trip_Characteristic_of_a_Thermomagnetic_Circuit_Breaker.svg</ref>]] Los DPCS se clasifican con una corriente máxima.<br/> *Tamaños de DPCS internacionales estándar: 1 A, 2 A, 4 A, 6 A, 10 A, 13 A, 16 A, 20 A, 25 A, 32 A, 40 A, 50 A, 63 A, 80 A, 100 A , 125 A, 150 A, 175 A, 200 A, 225 A, 250 A. <br/> *Tamaños estándar de DPCS de EE. UU. Según NEC de EE. UU .: 15 A, 20 A, 25 A, 30 A, 35 A, 40 A, 45 A, 50 A, 60 A, 70 A, 80 A, 90 A, 100 A, 110 A , 125 A, 150 A, 175 A, 200 A, 225 A, 250 A, 300 A, 350 A, 400 A, 450 A, 500 A. Hay algunos tamaños de fusibles estándar adicionales: 1, 3, 6, 10 y 601 A . ====Flujo de corriente==== Algunos circuitos en un sistema FV autónomo transportan corriente en ambas direcciones, como el circuito del sistema de almacenamiento de energía, mientras se carga y descarga. Esto puede ser un problema para ciertos tipos de interruptores que no están clasificados para el flujo de corriente en ambas direcciones. Si un interruptor está marcado en el costado que especifica una dirección para el flujo de corriente, generalmente con "línea" o "line en inglés" en la parte superior y "carga" o "load en inglés" en la parte inferior, entonces no debe usarse en un circuito que tenga flujo de corriente en ambas direcciones. ====Curva de disparo==== Los OCPD tendrán una curva de disparo que especifica cuánto tiempo el dispositivo puede mantener la corriente por encima de su capacidad de servicio continuo. Esto es deseable porque en los sistemas eléctricos a menudo hay [[Special:MyLanguage/Surge loads|cargas con corrientes de arranque]] que requieren corriente adicional durante un período muy breve al arrancar. Si un DPCS no tiene un ligero retardo de tiempo, se disparará cada vez que arranque una estas cargas. Para todos los circuitos típicos en un sistema FV autónomo, se recomienda un DPCS con un retardo de tiempo. ====Tensión máxima==== Los interruptores de CA y CC se clasifican para la tensión de circuito máximo con el que deben funcionar. Puede ser difícil encontrar DPCS clasificados para trabajar con CC a tensiónes más altas, por lo que suele usar fusibles en estos circuitos. ====Capacidad de interrupción==== La clasificación de capacidad de interrupción (AIC) es la capacidad del DPCS es la corriente máxima que el dispositivo puede aguantar y aún interrumpir el circuito. Esta clasificación suele ser cientos de veces la clasificación actual del interruptor con un interruptor doméstico típico de 15 A que tiene una clasificación AIC de 10.0000 A. Las clasificaciones AIC generalmente no son relevantes en el caso de sistemas FV autónomos. ====Tipo de montaje==== *Hay muchos tipos diferentes de portafusibles y sus correspondientes fusibles. Deben estar diseñados para trabajar juntos. *Los interruptores se diseñarán para montarse en un tipo específico de panel de distribución o en [[Special:MyLanguage/DIN rail|riel DIN]]. ==Tiempo de vida útil== *Los fusibles solo funcionan una vez y deben reemplazarse después de dispararse. Para sistemas FV autónomos, siempre se prefieren los interruptores automáticos por esta razón, ya que adquirir fusibles de reemplazo en ubicaciones remotas puede ser difícil. *Los interruptores automáticos normalmente pueden soportar un mínimo de cientos de fallas. Si un disyuntor falla, normalmente fallarán en un estado abierto (circuito desconectado). ==Mantenimiento== No es necesario realizar ningún mantenimiento en ninguno de los casos, salvo para asegurarse de que las conexiones al DPCS permanezcan firmes a lo largo del tiempo. ==Reciclabilidad== Los interruptores automáticos y fusibles estándares generalmente no contienen nada peligroso, pero deben reciclarse como desechos electrónicos, ya que las corrientes tradicionales de eliminación de desechos no pueden reciclarlos. ==Notas/referencias== <references/>
Navigation menu
Personal tools
English
Create account
Log in
Namespaces
Special page
Variants
Views
More
Search
Navigation
Main page
Recent changes
Random page
Help about MediaWiki
Tools
Special pages
Printable version