Export translations
Jump to navigation
Jump to search
Settings
Group
About OSSP
Basic stand-alone PV system components
Battery wiring
Busbar
Charge controller
Charge controller programming
Combiner box
Commissioning
Conductor size
Conductor types
Conduit
Continuous duty safety parameter
DC system voltage
DC-DC converter
Design parameter overview
Design process overview
DIN rail
Disconnect
Distribution panel
Duty cycle
Electrical codes
Electrical safety
Electricity and energy
Electricity types
Energy efficient loads
Energy storage
Energy storage sizing and selection
Equipment certification
Equipment clearances and safe working space
Ground fault protection device
Grounding system
Insolation
Installing module connectors
Insulation color
Inverter
Inverter programming
Irradiance safety parameter
Junction box
Labeling
Lead acid battery
Lighting
Lithium-ion battery
Load and solar resource comparison
Load evaluation
Low voltage disconnect
Low voltage disconnect parameter
Main Page
Module connectors
Mounting system types
Multimeters
OSSP stand-alone system design tool
Outlet
Overcurrent protection device
Peru
Physical evaluation
Power factor
Power flow between components
Principles of installation
PV module
PV source and charge controller sizing and selection overview
PV system types
Residual current device
Resources
Series and parallel connections
Shading
Shunt
Simplified energy storage sizing and selection
Simplified load evaluation
Simplified minimum PV source size
Simplified MPPT charge controller sizing and selection
Simplified physical evaluation
Simplified PWM charge controller sizing and selection
Simplified weather and solar resource evaluation
Site evaluation process overview
Stand-alone system configurations
Surge loads
Switch
Tilt and azimuth
Training providers
Troubleshooting
Twist-on wire connector
United States
Voltage and frequency by country
Voltage drop
Weather and solar resource evaluation
Weather rating
What is an off-grid PV system?
Wire terminal
Wiring basic load circuits
Wiring practices
Language
aa - Afar
ab - Abkhazian
abs - Ambonese Malay
ace - Achinese
ady - Adyghe
ady-cyrl - Adyghe (Cyrillic script)
aeb - Tunisian Arabic
aeb-arab - Tunisian Arabic (Arabic script)
aeb-latn - Tunisian Arabic (Latin script)
af - Afrikaans
ak - Akan
aln - Gheg Albanian
am - Amharic
an - Aragonese
ang - Old English
anp - Angika
ar - Arabic
arc - Aramaic
arn - Mapuche
arq - Algerian Arabic
ary - Moroccan Arabic
arz - Egyptian Arabic
as - Assamese
ase - American Sign Language
ast - Asturian
atj - Atikamekw
av - Avaric
avk - Kotava
awa - Awadhi
ay - Aymara
az - Azerbaijani
azb - South Azerbaijani
ba - Bashkir
ban - Balinese
bar - Bavarian
bbc - Batak Toba
bbc-latn - Batak Toba (Latin script)
bcc - Southern Balochi
bcl - Central Bikol
be - Belarusian
be-tarask - Belarusian (Taraškievica orthography)
bg - Bulgarian
bgn - Western Balochi
bh - Bhojpuri
bho - Bhojpuri
bi - Bislama
bjn - Banjar
bm - Bambara
bn - Bangla
bo - Tibetan
bpy - Bishnupriya
bqi - Bakhtiari
br - Breton
brh - Brahui
bs - Bosnian
btm - Batak Mandailing
bto - Iriga Bicolano
bug - Buginese
bxr - Russia Buriat
ca - Catalan
cbk-zam - Chavacano
cdo - Min Dong Chinese
ce - Chechen
ceb - Cebuano
ch - Chamorro
cho - Choctaw
chr - Cherokee
chy - Cheyenne
ckb - Central Kurdish
co - Corsican
cps - Capiznon
cr - Cree
crh - Crimean Turkish
crh-cyrl - Crimean Tatar (Cyrillic script)
crh-latn - Crimean Tatar (Latin script)
cs - Czech
csb - Kashubian
cu - Church Slavic
cv - Chuvash
cy - Welsh
da - Danish
de - German
de-at - Austrian German
de-ch - Swiss High German
de-formal - German (formal address)
din - Dinka
diq - Zazaki
dsb - Lower Sorbian
dtp - Central Dusun
dty - Doteli
dv - Divehi
dz - Dzongkha
ee - Ewe
egl - Emilian
el - Greek
eml - Emiliano-Romagnolo
en - English
en-ca - Canadian English
en-gb - British English
eo - Esperanto
es - Spanish
es-419 - Latin American Spanish
es-formal - español (formal)
et - Estonian
eu - Basque
ext - Extremaduran
fa - Persian
ff - Fulah
fi - Finnish
fit - Tornedalen Finnish
fj - Fijian
fo - Faroese
fr - French
frc - Cajun French
frp - Arpitan
frr - Northern Frisian
fur - Friulian
fy - Western Frisian
ga - Irish
gag - Gagauz
gan - Gan Chinese
gan-hans - Gan (Simplified)
gan-hant - Gan (Traditional)
gcr - Guianan Creole
gd - Scottish Gaelic
gl - Galician
glk - Gilaki
gn - Guarani
gom - Goan Konkani
gom-deva - Goan Konkani (Devanagari script)
gom-latn - Goan Konkani (Latin script)
gor - Gorontalo
got - Gothic
grc - Ancient Greek
gsw - Swiss German
gu - Gujarati
gv - Manx
ha - Hausa
hak - Hakka Chinese
haw - Hawaiian
he - Hebrew
hi - Hindi
hif - Fiji Hindi
hif-latn - Fiji Hindi (Latin script)
hil - Hiligaynon
ho - Hiri Motu
hr - Croatian
hrx - Hunsrik
hsb - Upper Sorbian
ht - Haitian Creole
hu - Hungarian
hu-formal - magyar (formal)
hy - Armenian
hyw - Western Armenian
hz - Herero
ia - Interlingua
id - Indonesian
ie - Interlingue
ig - Igbo
ii - Sichuan Yi
ik - Inupiaq
ike-cans - Eastern Canadian (Aboriginal syllabics)
ike-latn - Eastern Canadian (Latin script)
ilo - Iloko
inh - Ingush
io - Ido
is - Icelandic
it - Italian
iu - Inuktitut
ja - Japanese
jam - Jamaican Creole English
jbo - Lojban
jut - Jutish
jv - Javanese
ka - Georgian
kaa - Kara-Kalpak
kab - Kabyle
kbd - Kabardian
kbd-cyrl - Kabardian (Cyrillic script)
kbp - Kabiye
kg - Kongo
khw - Khowar
ki - Kikuyu
kiu - Kirmanjki
kj - Kuanyama
kjp - Eastern Pwo
kk - Kazakh
kk-arab - Kazakh (Arabic script)
kk-cn - Kazakh (China)
kk-cyrl - Kazakh (Cyrillic script)
kk-kz - Kazakh (Kazakhstan)
kk-latn - Kazakh (Latin script)
kk-tr - Kazakh (Turkey)
kl - Kalaallisut
km - Khmer
kn - Kannada
ko - Korean
ko-kp - Korean (North Korea)
koi - Komi-Permyak
kr - Kanuri
krc - Karachay-Balkar
kri - Krio
krj - Kinaray-a
krl - Karelian
ks - Kashmiri
ks-arab - Kashmiri (Arabic script)
ks-deva - Kashmiri (Devanagari script)
ksh - Colognian
ku - Kurdish
ku-arab - Kurdish (Arabic script)
ku-latn - Kurdish (Latin script)
kum - Kumyk
kv - Komi
kw - Cornish
ky - Kyrgyz
la - Latin
lad - Ladino
lb - Luxembourgish
lbe - Lak
lez - Lezghian
lfn - Lingua Franca Nova
lg - Ganda
li - Limburgish
lij - Ligurian
liv - Livonian
lki - Laki
lmo - Lombard
ln - Lingala
lo - Lao
loz - Lozi
lrc - Northern Luri
lt - Lithuanian
ltg - Latgalian
lus - Mizo
luz - Southern Luri
lv - Latvian
lzh - Literary Chinese
lzz - Laz
mai - Maithili
map-bms - Basa Banyumasan
mdf - Moksha
mg - Malagasy
mh - Marshallese
mhr - Eastern Mari
mi - Maori
min - Minangkabau
mk - Macedonian
ml - Malayalam
mn - Mongolian
mni - Manipuri
mnw - Mon
mo - Moldovan
mr - Marathi
mrj - Western Mari
ms - Malay
mt - Maltese
mus - Muscogee
mwl - Mirandese
my - Burmese
myv - Erzya
mzn - Mazanderani
na - Nauru
nah - Nāhuatl
nan - Min Nan Chinese
nap - Neapolitan
nb - Norwegian Bokmål
nds - Low German
nds-nl - Low Saxon
ne - Nepali
new - Newari
ng - Ndonga
niu - Niuean
nl - Dutch
nl-informal - Nederlands (informeel)
nn - Norwegian Nynorsk
no - Norwegian
nov - Novial
nqo - N’Ko
nrm - Norman
nso - Northern Sotho
nv - Navajo
ny - Nyanja
nys - Nyungar
oc - Occitan
olo - Livvi-Karelian
om - Oromo
or - Odia
os - Ossetic
pa - Punjabi
pag - Pangasinan
pam - Pampanga
pap - Papiamento
pcd - Picard
pdc - Pennsylvania German
pdt - Plautdietsch
pfl - Palatine German
pi - Pali
pih - Norfuk / Pitkern
pl - Polish
pms - Piedmontese
pnb - Western Punjabi
pnt - Pontic
prg - Prussian
ps - Pashto
pt - Portuguese
pt-br - Brazilian Portuguese
qqq - Message documentation
qu - Quechua
qug - Chimborazo Highland Quichua
rgn - Romagnol
rif - Riffian
rm - Romansh
rmy - Vlax Romani
rn - Rundi
ro - Romanian
roa-tara - Tarantino
ru - Russian
rue - Rusyn
rup - Aromanian
ruq - Megleno-Romanian
ruq-cyrl - Megleno-Romanian (Cyrillic script)
ruq-latn - Megleno-Romanian (Latin script)
rw - Kinyarwanda
sa - Sanskrit
sah - Sakha
sat - Santali
sc - Sardinian
scn - Sicilian
sco - Scots
sd - Sindhi
sdc - Sassarese Sardinian
sdh - Southern Kurdish
se - Northern Sami
sei - Seri
ses - Koyraboro Senni
sg - Sango
sgs - Samogitian
sh - Serbo-Croatian
shi - Tachelhit
shi-latn - Tachelhit (Latin script)
shi-tfng - Tachelhit (Tifinagh script)
shn - Shan
shy-latn - Shawiya (Latin script)
si - Sinhala
simple - Simple English
sk - Slovak
skr - Saraiki
skr-arab - Saraiki (Arabic script)
sl - Slovenian
sli - Lower Silesian
sm - Samoan
sma - Southern Sami
sn - Shona
so - Somali
sq - Albanian
sr - Serbian
sr-ec - Serbian (Cyrillic script)
sr-el - Serbian (Latin script)
srn - Sranan Tongo
ss - Swati
st - Southern Sotho
stq - Saterland Frisian
sty - cебертатар
su - Sundanese
sv - Swedish
sw - Swahili
szl - Silesian
ta - Tamil
tay - Tayal
tcy - Tulu
te - Telugu
tet - Tetum
tg - Tajik
tg-cyrl - Tajik (Cyrillic script)
tg-latn - Tajik (Latin script)
th - Thai
ti - Tigrinya
tk - Turkmen
tl - Tagalog
tly - Talysh
tn - Tswana
to - Tongan
tpi - Tok Pisin
tr - Turkish
tru - Turoyo
ts - Tsonga
tt - Tatar
tt-cyrl - Tatar (Cyrillic script)
tt-latn - Tatar (Latin script)
tum - Tumbuka
tw - Twi
ty - Tahitian
tyv - Tuvinian
tzm - Central Atlas Tamazight
udm - Udmurt
ug - Uyghur
ug-arab - Uyghur (Arabic script)
ug-latn - Uyghur (Latin script)
uk - Ukrainian
ur - Urdu
uz - Uzbek
uz-cyrl - Uzbek (Cyrillic script)
uz-latn - Uzbek (Latin script)
ve - Venda
vec - Venetian
vep - Veps
vi - Vietnamese
vls - West Flemish
vmf - Main-Franconian
vo - Volapük
vot - Votic
vro - Võro
wa - Walloon
war - Waray
wo - Wolof
wuu - Wu Chinese
xal - Kalmyk
xh - Xhosa
xmf - Mingrelian
xsy - Saisiyat
yi - Yiddish
yo - Yoruba
yue - Cantonese
za - Zhuang
zea - Zeelandic
zgh - Standard Moroccan Tamazight
zh - Chinese
zh-cn - Chinese (China)
zh-hans - Simplified Chinese
zh-hant - Traditional Chinese
zh-hk - Chinese (Hong Kong)
zh-mo - Chinese (Macau)
zh-my - Chinese (Malaysia)
zh-sg - Chinese (Singapore)
zh-tw - Chinese (Taiwan)
zu - Zulu
Format
Export for off-line translation
Export in native format
Fetch
{{DISPLAYTITLE:Multimeters}}[[Category:Basic concepts]] <languages /> Multimeters are the most important tool one has when working with electricity. A multimeter allows you to measure all of the important characteristics of a circuit or electrical system, which enables you to work safely and verify if a circuit is working correctly. There are many different types of multimeters that offer a variety of different functions. They range in cost dramatically as well. All multimeters, even cheap ones, should be able to perform the basic measurements that are required to do electrical work: voltage, current, resistance, conductivity, and frequency. That being said, it is important to make sure that the multimeter you are using is rated for use with the highest potential voltage and current that you intend to measure. If a multimeter is not rated to function under the conditions of use, it could destroy the multimeter and potentially cause severe harm. Multimeters are classified into various categories that inform users about their ability to handle excess voltages and current. These ratings go from the lowest rating being Category I (for use with small electronics with limited current and voltage sources) to Category IV (for use at the connection to the utility grid and all outdoor conductors).<ref name="lightning"> Fluke Application Note on multimeter categories https://content.fluke.com/promotions/promo-dmm/0518-dmm-campaign/dmm/fluke_dmm-chfr/files/safetyguidelines.pdf</ref> For small off-grid PV systems ''at least'' a Cat II - 600 V multimeter is recommended and should be fairly cheap. ==Functions of a multimeter== ===Voltage=== Any multimeter that is to be used have the ability to measure both DC and AC. It is important to understand the type of current that is going to be measured, as using the wrong setting can lead to a false reading which can be misleading and dangerous. A multimeter will have a dial that allows the user to select between AC and DC, which will be identified using the common symbols seen below. When working with a PV system, voltage is typically measured for the following reasons: *To check if there is voltage in a circuit before beginning to work. *To test the performance of a component in a PV system. Is the voltage within an acceptable range given the conditions? The battery should be fully charged, what is its voltage? *To identify where a problem is in a system by troubleshooting by testing various circuits and components in the system such as the battery, PV source, inverter, outlets, or light sockets. <gallery widths=100px> File:VoltagesymbolDC.png|''DC voltage'' File:VoltagesymbolAC.png|''AC voltage'' </gallery> ===Current=== Not all multimeters can take AC and DC current measurements, but for work with PV systems it is important to find one that does. There are two different ways to measure current with a multimeter, this is explored in the section - [[#Types of multimeters|types of multimeters]]. When working with a PV system, current measurements are typically taken for teh following reasons: *To check if there is any current flowing in a circuit before beginning to work. *To understand how the PV module or array is functioning. How much current is it producing under the conditions? *To understand power consumption for a system or various loads within a system. *To understand the flow of electricity. If the system is feeding a heavy load, what circuit or device is using the energy? <gallery widths=100px> File:CurrentsymbolDC.png|DC current File:CurrentsymbolAC.png|AC current </gallery> ===Resistance=== All components of an electrical system have some amount of internal resistance, but also resistance relative to other components of the system. When working with a PV system, resistance measurements are typically taken for the following reasons: *To ensure that a connection made in the system has a low enough resistance to function properly. High resistance connections can create heat and fires. *To ensure that there is a high resistance between the earth/ground and components of the system that should not have a connection of any kind to the ground like an [[Special:MyLanguage/Grounding system#Grounding terminology|ungrounded conductor]]. A low resistance connection in this case would signify a [[Special:MyLanguage/Grounding system#Ground faults|ground fault]]. '''Safety:''' Resistance measurements cannot be taken on circuits that have voltage or that have current flowing on them. Do not attempt it as it is can lead to injury or death. <gallery widths=100px> File:ohmsymbol.png|Resistance </gallery> ===Conductivity=== A conductivity check is a simplified resistance measurement. If a connection has a sufficiently low resistance - below a certain value that is set inside the multimeter - then the multimeter will emit a sound. If there is a high resistance between the two points of measurement, the multimeter will do nothing. Some common checks that are done with a conductivity test: *Check whether a breaker, fuse or switch is working. A fuse should have conductivity if it is still good. If it fails a conductivity test then it needs to be replaced and the reason for its failure investigated. *To test quickly whether a connection to a busbar or between two wires in a circuit was done properly. *To test whether a wire or system component is a part of a circuit. Often times wires are not properly identified, but a quick conductivity can often identify where that wire leads and to what it is connected. '''Safety:''' Conductivity checks cannot be taken on circuits that have voltage or that have current flowing on them. Do not attempt it. <gallery widths=100px> File:Continuitysymbol.png|Continuity </gallery> ===Frequency=== Frequency is a property of AC current. Inverters in an off-grid system should be operating within a specific frequency range, a frequency check can tell us that they are outside of this range and that there is a problem. AC frequency being out of this acceptable range can cause issues with appliances. <gallery widths=100px> File:Frequencysymbol.png|Frequency </gallery> ==Types of multimeters== [[File:Multimeter200927.png|frame|center|'''Multimeter types:'''<br />''Left -'' Clamp meter.<br />''Center -'' Traditional autoranging handheld multimeter.<br /> ''Right -'' Probes]] ===Traditional handheld multimeter=== These are the most common and economical multimeters on the market. For a low price they can perform many different functions and, if it is a decent brand, should be fairly accurate. These multimeters rely on probes to take all of measurements. These types of multimeters have at least three different ports and the probes must be rearranged depending upon the measurement. Taking voltage and current measurements - as seen in the diagram - always require the moving of the red probe to a different port as these two measurements use different circuits. As the multimeter measures current using probes, any current that is measured must pass through it, which is often limited to 10-15 A. There is an internal fuse that will be destroyed if one attempts to pass current in excess of its rated value through the multimeter. This means that one cannot take current measurements of circuits for which the maximum amount of current is not known. Nor can one take measurements of a source that can supply high amounts of current - like an outlet or a battery - as the multimeter simply provides a low resistance path for the current to pass through. If measuring currents near or in excess of 10A may be required, then it is necessary to get a clamp meter. These meters come in two types: ====Manual-ranging==== This type of multimeter requires the user to select the maximum voltage, current, or resistance in order to take a measurement. If too high of a range is used, it will lead to inaccurate measurements. If too low of a range is used, the multimeter will give an error. The cheapest multimeters are manual-ranging. For example: :*Example 1: You would like to take a voltage measurement of a circuit that you suspect to be 220 V AC. Your options on the multimeter are 120 V AC, 250 V AC, 500 V AC. What is the proper range for taking this measurement? :::Answer: 250 V AC. The 120 V AC setting will produce an error. The 500 V AC setting may produce an inaccurate reading. The 250 V AC setting will be able to provide the most accurate measurement. One technique that works with a manual ranging multimeter, is to start at the highest range, get a measurement and then work your way down to the lowest range capable of measuring a value in that range until there is an error. ====Auto-ranging==== This type of multimeter does the work of selecting the range itself and can save time for the user. For a slightly higher price than the price of manual ranging multimeter, it is possible purchase one that is auto-ranging. The additional cost is worth it if you will be using the meter frequently. ===Clamp meters=== Clamp meters are auto-ranging and share all of the basic functions of a traditional handheld multimeter, but they enable current measurements above 10 A to a certain limit, typically around 300-400 A. The multimeter performs current measurements by measuring the current that is flowing in a wire based upon the electro-magnetic field that it generates. To take a measurement one simply passes one wire of a circuit through the jaws of the clamp, which can easily be opened and closed by a button the side. It is important to only pass one wire of a circuit through the clamp because if both wires are passed through the currents will cancel out. A clamp meter is extremely useful, easy to use and significantly safer than a traditional handheld multimeter. The meters do cost slightly more, but the additional cost is is worth it if you will frequently take current measurements. ==Safely taking measurements with a multimeter== Like any tool, if a person doesn't know how to use a multimeter correclt it can be at best useless and at worst it can be dangerous. There are a few basic questions that should be asked and steps that should be taken when performing any measurements with a multimeter. #What type of current are you working with? #What is maximum amount of voltage and current that the circuit you want to measure could supply? #Do you have the proper training and tools to work on this equipment? #What do you want to measure and why? #What value should you get if everything is as it should be? #Configure the multimeter and check the voltage of the circuit before performing any other measurements to check if it is live. #Set your multimeter to the right setting for any other measurement that is necessary. #Carefully take the measurement and then check it against the anticipated value that you came up with in Step 5. ==Notes/references== <references/>
Navigation menu
Personal tools
English
Create account
Log in
Namespaces
Special page
Variants
Views
More
Search
Navigation
Main page
Recent changes
Random page
Help about MediaWiki
Tools
Special pages
Printable version