Export translations
Jump to navigation
Jump to search
Settings
Group
About OSSP
Basic stand-alone PV system components
Battery wiring
Busbar
Charge controller
Charge controller programming
Combiner box
Commissioning
Conductor size
Conductor types
Conduit
Continuous duty safety parameter
DC system voltage
DC-DC converter
Design parameter overview
Design process overview
DIN rail
Disconnect
Distribution panel
Duty cycle
Electrical codes
Electrical safety
Electricity and energy
Electricity types
Energy efficient loads
Energy storage
Energy storage sizing and selection
Equipment certification
Equipment clearances and safe working space
Ground fault protection device
Grounding system
Insolation
Installing module connectors
Insulation color
Inverter
Inverter programming
Irradiance safety parameter
Junction box
Labeling
Lead acid battery
Lighting
Lithium-ion battery
Load and solar resource comparison
Load evaluation
Low voltage disconnect
Low voltage disconnect parameter
Main Page
Module connectors
Mounting system types
Multimeters
OSSP stand-alone system design tool
Outlet
Overcurrent protection device
Peru
Physical evaluation
Power factor
Power flow between components
Principles of installation
PV module
PV source and charge controller sizing and selection overview
PV system types
Residual current device
Resources
Series and parallel connections
Shading
Shunt
Simplified energy storage sizing and selection
Simplified load evaluation
Simplified minimum PV source size
Simplified MPPT charge controller sizing and selection
Simplified physical evaluation
Simplified PWM charge controller sizing and selection
Simplified weather and solar resource evaluation
Site evaluation process overview
Stand-alone system configurations
Surge loads
Switch
Tilt and azimuth
Training providers
Troubleshooting
Twist-on wire connector
United States
Voltage and frequency by country
Voltage drop
Weather and solar resource evaluation
Weather rating
What is an off-grid PV system?
Wire terminal
Wiring basic load circuits
Wiring practices
Language
aa - Afar
ab - Abkhazian
abs - Ambonese Malay
ace - Achinese
ady - Adyghe
ady-cyrl - Adyghe (Cyrillic script)
aeb - Tunisian Arabic
aeb-arab - Tunisian Arabic (Arabic script)
aeb-latn - Tunisian Arabic (Latin script)
af - Afrikaans
ak - Akan
aln - Gheg Albanian
am - Amharic
an - Aragonese
ang - Old English
anp - Angika
ar - Arabic
arc - Aramaic
arn - Mapuche
arq - Algerian Arabic
ary - Moroccan Arabic
arz - Egyptian Arabic
as - Assamese
ase - American Sign Language
ast - Asturian
atj - Atikamekw
av - Avaric
avk - Kotava
awa - Awadhi
ay - Aymara
az - Azerbaijani
azb - South Azerbaijani
ba - Bashkir
ban - Balinese
bar - Bavarian
bbc - Batak Toba
bbc-latn - Batak Toba (Latin script)
bcc - Southern Balochi
bcl - Central Bikol
be - Belarusian
be-tarask - Belarusian (Taraškievica orthography)
bg - Bulgarian
bgn - Western Balochi
bh - Bhojpuri
bho - Bhojpuri
bi - Bislama
bjn - Banjar
bm - Bambara
bn - Bangla
bo - Tibetan
bpy - Bishnupriya
bqi - Bakhtiari
br - Breton
brh - Brahui
bs - Bosnian
btm - Batak Mandailing
bto - Iriga Bicolano
bug - Buginese
bxr - Russia Buriat
ca - Catalan
cbk-zam - Chavacano
cdo - Min Dong Chinese
ce - Chechen
ceb - Cebuano
ch - Chamorro
cho - Choctaw
chr - Cherokee
chy - Cheyenne
ckb - Central Kurdish
co - Corsican
cps - Capiznon
cr - Cree
crh - Crimean Turkish
crh-cyrl - Crimean Tatar (Cyrillic script)
crh-latn - Crimean Tatar (Latin script)
cs - Czech
csb - Kashubian
cu - Church Slavic
cv - Chuvash
cy - Welsh
da - Danish
de - German
de-at - Austrian German
de-ch - Swiss High German
de-formal - German (formal address)
din - Dinka
diq - Zazaki
dsb - Lower Sorbian
dtp - Central Dusun
dty - Doteli
dv - Divehi
dz - Dzongkha
ee - Ewe
egl - Emilian
el - Greek
eml - Emiliano-Romagnolo
en - English
en-ca - Canadian English
en-gb - British English
eo - Esperanto
es - Spanish
es-419 - Latin American Spanish
es-formal - español (formal)
et - Estonian
eu - Basque
ext - Extremaduran
fa - Persian
ff - Fulah
fi - Finnish
fit - Tornedalen Finnish
fj - Fijian
fo - Faroese
fr - French
frc - Cajun French
frp - Arpitan
frr - Northern Frisian
fur - Friulian
fy - Western Frisian
ga - Irish
gag - Gagauz
gan - Gan Chinese
gan-hans - Gan (Simplified)
gan-hant - Gan (Traditional)
gcr - Guianan Creole
gd - Scottish Gaelic
gl - Galician
glk - Gilaki
gn - Guarani
gom - Goan Konkani
gom-deva - Goan Konkani (Devanagari script)
gom-latn - Goan Konkani (Latin script)
gor - Gorontalo
got - Gothic
grc - Ancient Greek
gsw - Swiss German
gu - Gujarati
gv - Manx
ha - Hausa
hak - Hakka Chinese
haw - Hawaiian
he - Hebrew
hi - Hindi
hif - Fiji Hindi
hif-latn - Fiji Hindi (Latin script)
hil - Hiligaynon
ho - Hiri Motu
hr - Croatian
hrx - Hunsrik
hsb - Upper Sorbian
ht - Haitian Creole
hu - Hungarian
hu-formal - magyar (formal)
hy - Armenian
hyw - Western Armenian
hz - Herero
ia - Interlingua
id - Indonesian
ie - Interlingue
ig - Igbo
ii - Sichuan Yi
ik - Inupiaq
ike-cans - Eastern Canadian (Aboriginal syllabics)
ike-latn - Eastern Canadian (Latin script)
ilo - Iloko
inh - Ingush
io - Ido
is - Icelandic
it - Italian
iu - Inuktitut
ja - Japanese
jam - Jamaican Creole English
jbo - Lojban
jut - Jutish
jv - Javanese
ka - Georgian
kaa - Kara-Kalpak
kab - Kabyle
kbd - Kabardian
kbd-cyrl - Kabardian (Cyrillic script)
kbp - Kabiye
kg - Kongo
khw - Khowar
ki - Kikuyu
kiu - Kirmanjki
kj - Kuanyama
kjp - Eastern Pwo
kk - Kazakh
kk-arab - Kazakh (Arabic script)
kk-cn - Kazakh (China)
kk-cyrl - Kazakh (Cyrillic script)
kk-kz - Kazakh (Kazakhstan)
kk-latn - Kazakh (Latin script)
kk-tr - Kazakh (Turkey)
kl - Kalaallisut
km - Khmer
kn - Kannada
ko - Korean
ko-kp - Korean (North Korea)
koi - Komi-Permyak
kr - Kanuri
krc - Karachay-Balkar
kri - Krio
krj - Kinaray-a
krl - Karelian
ks - Kashmiri
ks-arab - Kashmiri (Arabic script)
ks-deva - Kashmiri (Devanagari script)
ksh - Colognian
ku - Kurdish
ku-arab - Kurdish (Arabic script)
ku-latn - Kurdish (Latin script)
kum - Kumyk
kv - Komi
kw - Cornish
ky - Kyrgyz
la - Latin
lad - Ladino
lb - Luxembourgish
lbe - Lak
lez - Lezghian
lfn - Lingua Franca Nova
lg - Ganda
li - Limburgish
lij - Ligurian
liv - Livonian
lki - Laki
lmo - Lombard
ln - Lingala
lo - Lao
loz - Lozi
lrc - Northern Luri
lt - Lithuanian
ltg - Latgalian
lus - Mizo
luz - Southern Luri
lv - Latvian
lzh - Literary Chinese
lzz - Laz
mai - Maithili
map-bms - Basa Banyumasan
mdf - Moksha
mg - Malagasy
mh - Marshallese
mhr - Eastern Mari
mi - Maori
min - Minangkabau
mk - Macedonian
ml - Malayalam
mn - Mongolian
mni - Manipuri
mnw - Mon
mo - Moldovan
mr - Marathi
mrj - Western Mari
ms - Malay
mt - Maltese
mus - Muscogee
mwl - Mirandese
my - Burmese
myv - Erzya
mzn - Mazanderani
na - Nauru
nah - Nāhuatl
nan - Min Nan Chinese
nap - Neapolitan
nb - Norwegian Bokmål
nds - Low German
nds-nl - Low Saxon
ne - Nepali
new - Newari
ng - Ndonga
niu - Niuean
nl - Dutch
nl-informal - Nederlands (informeel)
nn - Norwegian Nynorsk
no - Norwegian
nov - Novial
nqo - N’Ko
nrm - Norman
nso - Northern Sotho
nv - Navajo
ny - Nyanja
nys - Nyungar
oc - Occitan
olo - Livvi-Karelian
om - Oromo
or - Odia
os - Ossetic
pa - Punjabi
pag - Pangasinan
pam - Pampanga
pap - Papiamento
pcd - Picard
pdc - Pennsylvania German
pdt - Plautdietsch
pfl - Palatine German
pi - Pali
pih - Norfuk / Pitkern
pl - Polish
pms - Piedmontese
pnb - Western Punjabi
pnt - Pontic
prg - Prussian
ps - Pashto
pt - Portuguese
pt-br - Brazilian Portuguese
qqq - Message documentation
qu - Quechua
qug - Chimborazo Highland Quichua
rgn - Romagnol
rif - Riffian
rm - Romansh
rmy - Vlax Romani
rn - Rundi
ro - Romanian
roa-tara - Tarantino
ru - Russian
rue - Rusyn
rup - Aromanian
ruq - Megleno-Romanian
ruq-cyrl - Megleno-Romanian (Cyrillic script)
ruq-latn - Megleno-Romanian (Latin script)
rw - Kinyarwanda
sa - Sanskrit
sah - Sakha
sat - Santali
sc - Sardinian
scn - Sicilian
sco - Scots
sd - Sindhi
sdc - Sassarese Sardinian
sdh - Southern Kurdish
se - Northern Sami
sei - Seri
ses - Koyraboro Senni
sg - Sango
sgs - Samogitian
sh - Serbo-Croatian
shi - Tachelhit
shi-latn - Tachelhit (Latin script)
shi-tfng - Tachelhit (Tifinagh script)
shn - Shan
shy-latn - Shawiya (Latin script)
si - Sinhala
simple - Simple English
sk - Slovak
skr - Saraiki
skr-arab - Saraiki (Arabic script)
sl - Slovenian
sli - Lower Silesian
sm - Samoan
sma - Southern Sami
sn - Shona
so - Somali
sq - Albanian
sr - Serbian
sr-ec - Serbian (Cyrillic script)
sr-el - Serbian (Latin script)
srn - Sranan Tongo
ss - Swati
st - Southern Sotho
stq - Saterland Frisian
sty - cебертатар
su - Sundanese
sv - Swedish
sw - Swahili
szl - Silesian
ta - Tamil
tay - Tayal
tcy - Tulu
te - Telugu
tet - Tetum
tg - Tajik
tg-cyrl - Tajik (Cyrillic script)
tg-latn - Tajik (Latin script)
th - Thai
ti - Tigrinya
tk - Turkmen
tl - Tagalog
tly - Talysh
tn - Tswana
to - Tongan
tpi - Tok Pisin
tr - Turkish
tru - Turoyo
ts - Tsonga
tt - Tatar
tt-cyrl - Tatar (Cyrillic script)
tt-latn - Tatar (Latin script)
tum - Tumbuka
tw - Twi
ty - Tahitian
tyv - Tuvinian
tzm - Central Atlas Tamazight
udm - Udmurt
ug - Uyghur
ug-arab - Uyghur (Arabic script)
ug-latn - Uyghur (Latin script)
uk - Ukrainian
ur - Urdu
uz - Uzbek
uz-cyrl - Uzbek (Cyrillic script)
uz-latn - Uzbek (Latin script)
ve - Venda
vec - Venetian
vep - Veps
vi - Vietnamese
vls - West Flemish
vmf - Main-Franconian
vo - Volapük
vot - Votic
vro - Võro
wa - Walloon
war - Waray
wo - Wolof
wuu - Wu Chinese
xal - Kalmyk
xh - Xhosa
xmf - Mingrelian
xsy - Saisiyat
yi - Yiddish
yo - Yoruba
yue - Cantonese
za - Zhuang
zea - Zeelandic
zgh - Standard Moroccan Tamazight
zh - Chinese
zh-cn - Chinese (China)
zh-hans - Simplified Chinese
zh-hant - Traditional Chinese
zh-hk - Chinese (Hong Kong)
zh-mo - Chinese (Macau)
zh-my - Chinese (Malaysia)
zh-sg - Chinese (Singapore)
zh-tw - Chinese (Taiwan)
zu - Zulu
Format
Export for off-line translation
Export in native format
Fetch
[[Category:Energy storage]] <languages /> [[File:Crossection.png|thumb|right|A lead acid battery with the case removed. The inside of a lead acid battery is composed of lead plates immersed in an electrolyte solution.]] Lead acid batteries rely on reversible chemical reactions between lead and acid to provide energy when it is needed and to store energy when it is being produced. They have been around for over 150 years and have proven their durability, low-cost, recyclability, and performance under variable conditions to the point that nearly every automobile on the planet relies on a lead acid battery to start and run. Lead acid batteries have been the preferred form of energy storage for off-grid PV systems since they first began being built for the previously mentioned reasons, thus most off-grid PV components are built for use with lead acid batteries in 12 V, 24 V or 48 V configurations. Lead acid batteries have the added advantage of coming in a variety of voltages (2 V, 6 V, 8 V, 12 V) and amp-hour ratings (5 Ah to 5000+ Ah). But due to their high density of lead, these batteries are extremely heavy. A 12 V, 225 Ah flooded lead acid battery weighs around 60 kg, which is approaching the upper-limit of what is easily movable without equipment. Just like how a [[Special:MyLanguage/PV module|PV module]] is comprised of various different PV cells connected together in [[Special:MyLanguage/Series and parallel connections|series]] that each produce a certain voltage, lead acid batteries are composed of series connected cells with each one producing around being having a [[Special:MyLanguage/Energy storage#Nominal voltage|nominal voltage]] of roughly 2 V. This means that a 12 V battery will consist of 6 cells. There are many different types of lead acid batteries, but they can initially be divided into two categories: starter batteries and deep-cycle batteries. *Starter batteries are used in cars and are intended to provide large amounts of power for short periods of time with a shallow [[Special:MyLanguage/Energy storage#Depth of discharge (DoD)|depth of discharge]]. They work well for this purpose, but they are unable to continuously supply power beyond a shallow depth of discharge without severely shortening their [[Special:MyLanguage/Energy storage#Cycle life|cycle life]]. These batteries will fail prematurely in a PV system and are not worth investing in. *Deep-cycle batteries have a more robust design that enables them to continuously supply high amounts of power to a deeper depth of discharge - generally considered to be around 80%. These batteries are heavier and cost more than starter batteries but are the appropriate battery for use with a PV system. There are various different types of lead acid batteries, but this page will focus on the two main categories: flooded lead acid (FLA) and valve regulated lead acid (VRLA) deep-cycle batteries. ==Flooded lead acid (FLA)== [[File:Leadacidcomparison210103.png|thumb|'''Diagrams comparing different lead acid battery types. The outermost ring is the highest rating or performance. Innermost ring is the lowest rating or perfomance.'''<ref name="trojanbatterycomparison"> Trojan Battery Company - Selecting the Proper Lead-Acid Technology http://www.trojanbattery.com/pdf/Trojan_AGMvsFloodedvsGel_121718.pdf</ref><br/> ''(1)'' Energy density ''(2)'' Power density ''(3)'' Cost ''(4)'' Safety ''(5)'' Cycle life ''(6)'' Temperature range ''(7)'' Maintenance ''(8)'' Efficiency]] The original lead acid battery design. They are the simplest, most durable, and cheapest of the lead acid batteries. They are slightly more durable as they tend to be more forgiving of deep discharges than maintenance-free VRLA batteries. Characteristics: *They require monthly maintenance as the batteries will lose water as they charge and discharge. Durable, long cycle life and cheap only if properly maintained. If maintenance is not performed regularly, the batteries will rapidly fail, and replacement will cost significantly if maintenance-free batteries had been used initially. *Release significant amounts of hydrogen gas. *Have a liquid electrolyte solution inside that requires that they remain upright. *Can undergo an [[Special:MyLanguage/Charge controller#Equalization charge|equalization charge]] which can help to prolong their [[Special:MyLanguage/Energy storage#Cycle life|cycle life]] by reducing [[#Sulfation|sulfation]]. Considerations for use: *End users that are capable of maintaining a battery (with proper training and protective equipment) or in a location where the system can be serviced by technicians. *Users must have reliable access to distilled water was any other form of water has impurities and will damage the battery over time. *Require a secure space with proper ventilation due to the combined hazard of the batteries spilling acid and their tendency to release significant amounts of hydrogen gas. They also create a noxious sulfur smell. The combination of these risks means that ideally flooded batteries should always be stored in a room that is secure and not regularly inhabited like a storage room, shed, or garage. *May not be the best battery type with either extreme high or low temperatures. *Low budget and high energy needs. ==Valve-regulated lead acid (VRLA)== In the 1970's valve-regulated lead acid batteries began to enter the market. These batteries solved many of the major faults with flooded lead acid batteries: they are maintenance-free, they do not have a liquid acid electrolyte that can be spilled, and they do not expel significant amoutns of hydrogen. There are trade-offs though: they are less durable because they are not as tolerant of deep discharges, they have a shorter cycle life and they cost significantly more than flooded lead acid batteries. There are two primary sub-categories of VRLA batteries: Absorption glass mat (AGM) and Gel. Characteristics: *They do not require maintenance. *They are sealed (although not completely) so there is little to no off-gassing. *They do not have a liquid electrolyte solution inside and are additionally sealed to prevent leaks, therefore they do not have to be positioned upright at all times. Considerations for use: *End users that may not perform maintenance. *Locations in which there is not a separate space that can be dedicated to energy storage. These batteries cannot create hazardous spills, emit significant amounts of hazardous gases, or emit a noxious sulfur smell. They still should be securely stored in a battery box, but they can be located in a multi-use space if necessary. *Require a higher budget. ===Absorption glass mat (AGM)=== A VRLA battery in which the electrolyte solution is contained within mats of fine glass fibers. These batteries cost on average 1.5-2 times as much as FLA and have a shorter cycle life when compared to a properly maintained FLA battery. Specific considerations for use: *Permit higher charge and discharge rates than FLA and gel batteries. *Perform better than FLA and gel batteries in cold environments. FLA batteries can freeze and be damaged during charging and discharging. ===Gel=== A VRLA battery in which the electrolyte solution is made into a gel paste. Gel batteries are the costliest lead acid option. They prefer slow charging and discharging, which is not ideal for renewable energy systems that often do both everyday. Specific considerations for use: *Perform better than AGM and FLA batteries in hot environments. ==Storage capacity== The [[Special:MyLanguage/Energy storage#Storage capacity|storage capacity]] of a lead acid battery is measured in amp-hours (Ah). The amount of this energy that is actually [[Special:MyLanguage/Energy storage#Usable energy|usable energy]] depends upon: #The rate at which energy is withdrawn. If a battery lead acid battery is discharged rapidly, the amount of usable energy decreases. Conversely, if discharged slowly, the usable energy increases. This is measured in in terms of C-rate. A C-rate of 1 means that the entire capacity of the battery is discharged in 1 hour. A C-rate of 20 or C/20 means that the entire capacity of the battery is discharged over the course of 20 hours. Lead acid batteries are typically rated by their C/20 rate. Below is an example for a Trojan 12 V 205 Ah AGM battery:<ref name="trojan205agm"> Trojan Battery Company - Specifications sheet for 12 V 205 Ah AGM battery https://www.trojanbattery.com/pdf/SAGM_12_205_AGM_DS.pdf</ref> ::{| class="wikitable" border=1 !C-rate !Amp-hours |- |10 hour |174Ah |- style="background-color:#F08080;" |20 hour |205Ah |- |48 hour |210Ah |- |72 hours |213Ah |- |100 hours |216Ah |} <ol start="2"> <li>The chosen depth of discharge limit for a battery. The [[Special:MyLanguage/Energy storage#Cycle life|cycle life]] of a battery depends greatly upon how deeply it is discharged and how frequently. The numbers of cycles vary depending upon the type of battery as well.</li> <gallery heights=300px widths=300px> File:DoDcycles.png|Depth of discharge vs. cycle life for Trojan FLA, AGM and Gel batteries.<ref name="trojanfla"> Trojan Battery Company - Specifications sheet for FLA batteries https://www.trojanbattery.com/pdf/Signature_Trojan_ProductLineSheet.pdf</ref><ref name="trojanagm2"> Trojan Battery Company - Specifications sheet for AGM batteries https://www.trojanbattery.com/pdf/AGM_Trojan_ProductLineSheet.pdf</ref><ref name="trojangel"> Trojan Battery Company - Specifications sheet for Gel batteries https://www.trojanbattery.com/pdf/GEL_Trojan_ProductLineSheet.pdf</ref> </gallery> </ol> ==Temperature== The temperature of a lead acid battery or battery cell directly influences its resting voltage and the voltages at which it should be charged. It is worth noting that batteries have significant thermal mass, so brief periods of high or low ambient temperatures do not tend to quickly change battery temperature on their own. Batteries do internally generate heat as they charge and discharge. Higher temperatures give batteries an increased capacity, but also greatly shortens their life. For lead acid batteries it is estimated that for every 10°C increase in average temperature above 25°C shortens the batteries life by half. This means that operating a lead acid battery for one month at 35°C is equivalent in terms of battery life to operating the battery for two months at 25°C<ref name="trojan205agm"/>. Low temperatures decrease the capacity of all lead acid batteries can leave them prone to damage during charing and discharging. Extremely low temperatures can cause flooded lead acid batteries to freeze, which can crack the case of the battery and cause electrolyte to spill. The freezing point of flooded lead acid batteries varies with their state of charge. For all lead acid batteries it is important to use them lightly if they are at a very low temperature (below -10°C). Locating the batteries in an appropriate location and properly storing them is essentially to ensure that a system performs properly. A charge controller that is able to take into account battery temperature through a remote sensor can greatly prolong battery life and avoid accidental overcharging that can severely damage batteries. <gallery heights=300px widths=300px> File:Tempcapacity.png|Capacity vs. temperature for Trojan FLA, AGM and Gel batteries.<ref name="trojanfla"/><ref name="trojanagm2"/><ref name="trojangel"/> File:Tempvoltage.png|Cell voltage vs. temperature for Trojan FLA, AGM, and Gel batteries.<ref name="trojanfla"/><ref name="trojanagm2"/><ref name="trojangel"/> </gallery> ==Efficiency== There is no type of storage that is perfectly efficient. Lead acid batteries inherently lose some energy as it is put into the battery and some as it is withdrawn, generally as heat. A FLA battery is typically only 80-85% efficient, whereas a VRLA battery is has a slightly higher efficiency of 85-90% efficiency. This is round -trip efficiency, meaning that if 100Wh of energy arrives from a PV module is stored in a lead acid battery that: *80-85 Wh will be able to be withdrawn from the FLA battery. *85-90 Wh will be able to be withdrawn from the VRLA battery. ==Charging== Lead acid batteries have specific charging requirements that must be followed to ensure that they continue functioning for a their rated [[Special:MyLanguage/Energy storage#Cycle life|cycle life]]. For more information on the the different charging phases - see [[Special:MyLanguage/Charge controller#Charging phases|Charging phases]]. ====Sulfation==== It is important that batteries reach a full state of charge (90-100%) on a regular basis. If batteries do not reach a full state of charge every few days, then the plates within the battery will begin a process of ''sulfation'' which is the buildup of sulfate crystals on the plates of the battery that will start to impede performance and can ultimately lead the battery to cease functioning. Although a 30% depth of discharge is rather shallow for off-grid systems, if a battery regularly sits at 70% state of charge (the inverse of a 30% DoD) the batteries will begin to sulfate, lose performance, and fail prematurely. It is necessary to build a system with a PV charging source that can supply sufficient current to bring the batteries up to charge regularly while loads continue to operate. With FLA batteries it is possible to do a monthly [[Special:MyLanguage/Charge controller#Equalization charge|equalization charge]] to reduce sulfation, but this is not possible with VRLA batteries. ====Charge rate==== If an off-grid PV system will rely solely upon PV as a charging source (no generator, no other renewables) then it is necessary to ensure that a PV source is properly sized for this role. The PV source size should be checked to ensure that it can supply sufficient current to properly charge the [[Special:MyLanguage/Energy storage|energy storage system]]. If lead acid batteries do not regularly receive an adequate charging current - typically because the PV source is undersized relative to the energy storage system - they will begin to experience sulfation and they will last for fewer [[Special:MyLanguage/Energy storage#Cycle life|cycles]]. Lead acid batteries last longer and perform better when they are regularly recharged with a current in a certain range - typically between 5-13% of their C/20 rating.<ref name="trojanpaper"> Trojan Battery Company - User's Guide https://www.trojanbattery.com/pdf/TrojanBattery_UsersGuide.pdf</ref><ref name="rollspaper"> The maximum charging current for most lead acid batteries is around 13% of the C/20 rate. Rolls Battery - Battery User Manual https://rollsbattery.com/public/docs/user_manual/Rolls_Battery_Manual.pdf</ref> It is best practice to consult the manual or manufacturer for recommended maximum and minimum charging currents. If a system uses many loads during the day, this will limit the available charging current for the energy storage system and should be taken into account. *A minimum of 5% of the C/20 Ah rating is recommended for a system that is used infrequently or is primarily used at night.<ref name="trojanpaper"/><ref name="rollspaper"/> *A 10% of the C/20 Ah rating is recommended for a system that is used regularly with significant load usage during the day. *A maximum of 13% of the C/20 Ah rating is recommended for gel and flooded lead acid batteries. A maximum of 20% of the C/20 rate Ah rating is recommended for AGM batteries..<ref name="trojanpaper"/> ==Discharge rate== Lead acid batteries have a recommended maximum continuous discharge current which is typically the same as the maximum charge current of the battery. This rate can be exceeded for brief periods of time when surge loads are operating or a heavy load, like a well pump, is operating for a few minutes, but the size of the energy storage system should be increased if the amount of current that the inverter will require to operate at its continuous duty rating exceeds the recommended value for the battery. Commonly used values for the maximum continous discharge current for different lead acid batteries are as follows:<ref name="trojanpaper"/> *A maximum of 13% of the C/20 Ah rating is recommended for flooded and gel batteries. *A maximum of 20% of the C/20 Ah rating is recommended for AGM batteries. It is important to consult the manufacturer of a particular battery as there are batteries that permit higher charge or discharge currents. ==Battery storage== [[File:Batterybox201231.png|thumb|A battery box with a hinged lid, an entrance for cables and added ventilation.]] Due to safety issues posed by batteries (high available current, hazardous gases, dangerous chemicals) it is always necessary to put batteries in a secure enclosure or room to avoid unauthorized access to them. For small-scale off-grid systems they are typically housed in a battery box that is constructed to the required size of the battery bank. The most common and easy to work with material in most areas is wood, but it is also possible to build a suitable enclosure out of metal or plastic. Batteries should be checked regularly and serviced as needed, therefore it is important that any type of enclosure that they are placed into provides sufficient working space. ====Location and security==== Batteries must be placed in a location that will provide adequate cooling, a dry environment, and protection from unauthorized access. It is best practice to avoid installing batteries or other electrical equipment in living quarters meaning bedrooms, kitchens, or living rooms. This is especially true with flooded lead acid batteries as they generate a noxious sulfur smell during charging. This is often not possible in many locations due the lack an additional appropriate space or concerns over theft. In this case, using VRLA (sealed) batteries and installing them in the living room would be preferrable to a bedroom or bathroom. If a battery box is to be placed in an accessible location, then it is necessary that it has a means to avoid unauthorized access, like a lock. If the batteries are in a room without a battery box, it is necessary that the room itself be locked to avoid unauthorized access. A battery box should not be become means for storage - adequate space should always be left so that the lid can easily be opened without the need to move other items. Many batteries come with a rubber or plastic cover for the terminals, this can be a useful safety measure to prevent accidental [[Special:MyLanguage/Electricity and energy#Circuits|short-circuits]] from accidents like tools being dropped across the terminals. ====Ventilation==== FLA batteries release potentially explosive hydrogen during charging, therefore it is recommended that they are stored in a location with adequate free airflow. This is additionally important for cooling. If batteries are to be placed in a battery box, then holes should be made near the top and bottom of the box to enable rising hydrogen - which rises because it is lighter than most other molecules - to escape and other air to enter. A sloped lid on the battery box can help to improve ventilation. It is also a best practice to locate the point where any cables exist near the bottom of the battery box to avoid any hydrogen entering the conduit and making its way to the other electrical equipment. AGM batteries do not release hydrogen during normal charging, but it would nonetheless be a good practice to follow the same practices recommended for batteries. At the minimum they should be provided good ventilation to provide appropriate cooling to avoid overheating during charging. ====Spacing between batteries==== Adequate spacing is important to permit adequate cooling of batteries and to permit safe working conditions. In cool climates - maximum temperature indoors under 30°C - a battery bank should allow for: *At least 2.5 cm should be left between batteries. *At least 15 cm of perimeter around the batteries. This may be 15cm between the batteries and the sides of the battery box or 15cm between the batteries and the nearest object if they are not in a box. In warmer climates, more spacing can be provided and additional considerations should be taken to ensure adequate battery cooling. In cooler climates, insulating the battery box may be an appropriate choice to improve performance and prevent freezing. ====Spill containment with FLA batteries==== As FLA batteries contain an acidic electrolyte in liquid form, it is common for them to overflow during maintenance or if they are over-charged. It is important to build a spill containment system that can handle the amount of electrolyte that a battery bank could potentially spill. Placing the batteries in a plastic or rubber tray with a tip of at least 5 cm is recommended. ==Date of battery production== It is important to understand the age of batteries when purchasing them and when servicing them. Batteries use a unique dating system. The month of production corresponds to a letter - beginning with "A" for December. The letter "I" is skipped due to its similarity to the number "1." The year of production corresponds to a number with "0" being the first year of a decade. For example a batter produced in March of 2018 would have a date code of "C8." [[File:Datecodeshorizontal201002.png|frame|center|''Top row:'' letter system for months. ''Bottom row:'' number system for years.]] ==Safety== [[File:Ppebattery-201001.png|thumb|right|200px|Basic PPE for working with lead acid batteries.]] Lead acid batteries contain lead and acid, both of which are hazardous if they come into contact with the skin or are ingested. Installing, maintaining, or troubleshooting lead acid battery banks requires that appropriate personal protective equipment is worn at all times with the bare minimum being eye protection and gloves. Baking soda and water should always be stored in case of contact with the acidic electrolyte solution or if a spill were to occur. Baking soda is a basic substance, which is the opposite of an acid, and will work to neutralize the hazardous effects of the acid. Water works to dilute the acid and wash it away to minimize damage. If acid comes into contact with eyes or skin, baking soda can be applied and then area should be washed thoroughly and continuously for at least 15 minutes to dilute and remove the acid. If electrolyte solution comes into contact with clothing, it should also be neutralized with baking soda and diluted or else it will eat away the clothing. It is a good practice to store the appropriate personal protective equipment, baking soda, and water in the same location where with the batteries. After working with lead acid batteries, even if gloves were used, hands should be washed thoroughly to remove lead with which they may have accidentally come into contact. For more information on electrical safety when working with batteries see: [[Special:MyLanguage/Electrical safety#Safety with batteries|Electrical safety with batteries]]. ==Recyclability== Lead acid batteries contain lead and acid, both of which are hazardous materials that must be disposed of properly<ref name="gizreport"> GIZ report on End-of-Life Management of Batteries in the Off-Grid Solar Sector https://www.giz.de/de/downloads/giz2018-en-waste-solar-guide.pdf</ref>. Lead acid batteries are often pointed to as a success story for recycling as the majority of lead is used for batteries and an estimated 95-96% is ultimately recycled<ref name="unmetals"> United Nations Enviromental Program report on recycling metals https://wedocs.unep.org/bitstream/handle/20.500.11822/8702/Recycling_Metals.pdf?sequence=1&isAllowed=y</ref>. This largely has to do with a well-developed market, supply chain and abundant processing facilities for lead acid batteries as lead is a valuable material and is readily recyclable. This knowledge has spread and has resulted in batteries being returned for cash in even the most remote places. == Notes/references== <references/> [https://www.energy.gov/sites/prod/files/2019/07/f65/Storage%20Cost%20and%20Performance%20Characterization%20Report_Final.pdf Hydrowires - Energy Storage Technology and Cost Characterization Report]<br /> Isidor Buchman - Batteries in a Portable World<br /> Thomas Reddy - Linden's Handbook of Batteries, 4th Edition
Navigation menu
Personal tools
English
Create account
Log in
Namespaces
Special page
Variants
Views
More
Search
Navigation
Main page
Recent changes
Random page
Help about MediaWiki
Tools
Special pages
Printable version