− | A module is tested and rated based upon the following values which can be found printed on the module or in its specifications sheet: | + | A PV module is tested and rated based upon the following values which can be found printed on the module or in its specifications sheet: |
− | *Open circuit voltage (Voc) – The voltage that the module will produce under STC when it is | + | *Open circuit voltage (Voc) – The voltage that the module will produce under STC when it is in an [[Special:MyLanguage/Electricity and energy#Circuits|open circuit]] (disconnected, no current flow). |
− | *Short circuit current (Isc) – The current that a module will produce under STC when it is [[Electricity and energy#Circuits|short-circuited]] | + | *Short circuit current (Isc) – The current that a module will produce under STC when it is [[Special:MyLanguage/Electricity and energy#Circuits|short-circuited]]. (All available curent flowing with minimal resistance, for example when the positive output of a PV module is connected directly connected to its negative). |
*Maximum power voltage (Vmp) – The voltage that the module will produce when connected to a circuit under STC. | *Maximum power voltage (Vmp) – The voltage that the module will produce when connected to a circuit under STC. | ||
*Maximum power current (Imp) – The current that the module will produce when connected to a circuit under STC. | *Maximum power current (Imp) – The current that the module will produce when connected to a circuit under STC. | ||
− | *Temperature coefficient of power ( | + | *Temperature coefficient of power (Tkpmp) - A coefficient that accounts for how module power responds to increases and decreases in temperature in %/°C or V/°C. |
− | *Temperature coefficient of open circuit voltage ( | + | *Temperature coefficient of open circuit voltage (Tkvoc) - A coefficient that accounts for how module voltage responds to increases and decreases in temperature in %/°C or V/°C. |
Latest revision as of 20:26, 9 February 2021
A PV module is tested and rated based upon the following values which can be found printed on the module or in its specifications sheet:
- Open circuit voltage (Voc) – The voltage that the module will produce under STC when it is in an open circuit (disconnected, no current flow).
- Short circuit current (Isc) – The current that a module will produce under STC when it is short-circuited. (All available curent flowing with minimal resistance, for example when the positive output of a PV module is connected directly connected to its negative).
- Maximum power voltage (Vmp) – The voltage that the module will produce when connected to a circuit under STC.
- Maximum power current (Imp) – The current that the module will produce when connected to a circuit under STC.
- Temperature coefficient of power (Tkpmp) - A coefficient that accounts for how module power responds to increases and decreases in temperature in %/°C or V/°C.
- Temperature coefficient of open circuit voltage (Tkvoc) - A coefficient that accounts for how module voltage responds to increases and decreases in temperature in %/°C or V/°C.