The design process for an off-grid PV system should use conservative, worst-case values to ensure that the system is capable of meeting the energy needs of users throughout the year. There are many locations that have a significant seasonal variance in [[Weather and solar resource evaluation|solar resource]] due to poor weather or latitude. Many off-grid PV systems will see a significant variance in [[Load evaluation|how loads are used throughout the year]], especially in locations that are only seasonally occupied. These two different factors - load usage vs. solar resource - make it important to determine what month to use in the system design as the worst-case scenario. An analysis of loads and usage could be performed on a monthly basis, but the most drastic shift in usage likely occurs between the major seasons in a given region meaning two to four times per year. Determining the worst-case month can be done using a simple table and a quick calculation. The values and calculation can be performed in Wh or kWh - the ratio is what is important. The two following values used for the design should be chosen from the month with the highest ratio of average daily watt-hours relative to average monthly insolation:
+
The design process for an off-grid PV system should use conservative, worst-case values to ensure that the system is capable of meeting the energy needs of users throughout the year. There are many locations that have a significant seasonal variance in [[Weather and solar resource evaluation|solar resource]] due to poor weather or latitude. Many off-grid PV systems will see a significant variance in [[Load evaluation|how loads are used throughout the year]], especially in locations that are only seasonally occupied. These two different factors - load usage vs. solar resource - make it important to determine what month to use in the system design as the worst-case scenario. An analysis of loads and usage could be performed on a monthly basis, but the most drastic shift in usage likely occurs between the major seasons in a given region meaning two times per year. Determining the worst-case month can be done using a simple table and a quick calculation using [[Weather and solar resource evaluation|monthly insolation data]] and [[Load evaluation|Average daily Wh estimates]] for the two different time periods October - March and April - September. The values and calculation can be performed in Wh or kWh - the ratio is what is important. The two following values used for the design should be chosen from the month with the highest ratio of average daily watt-hours relative to average monthly insolation:
  
 
*Design daily insolation
 
*Design daily insolation

Revision as of 10:49, 19 December 2020

The design process for an off-grid PV system should use conservative, worst-case values to ensure that the system is capable of meeting the energy needs of users throughout the year. There are many locations that have a significant seasonal variance in solar resource due to poor weather or latitude. Many off-grid PV systems will see a significant variance in how loads are used throughout the year, especially in locations that are only seasonally occupied. These two different factors - load usage vs. solar resource - make it important to determine what month to use in the system design as the worst-case scenario. An analysis of loads and usage could be performed on a monthly basis, but the most drastic shift in usage likely occurs between the major seasons in a given region meaning two times per year. Determining the worst-case month can be done using a simple table and a quick calculation using monthly insolation data and Average daily Wh estimates for the two different time periods October - March and April - September. The values and calculation can be performed in Wh or kWh - the ratio is what is important. The two following values used for the design should be chosen from the month with the highest ratio of average daily watt-hours relative to average monthly insolation:

  • Design daily insolation
  • Design daily watt-hours required

Step 1: Determine monthly ratio of consumption to solar resource

Month Average daily insolation Average daily watt-hours required Ratio
January
February
March
April
May
June
July
August
September
October
November
December

Step 2: Determine design values

Design daily insolation = Average monthly insolation from month with the highest ratio ÷ 30
Design daily watt-hours required = Average daily watt-hours from month with the highest ratio