Difference between revisions of "Wiring practices"
Jump to navigation
Jump to search
Line 1: | Line 1: | ||
[[Category:System installation]] | [[Category:System installation]] | ||
Wire nuts, leaving extra copper, leaving extra wire. | Wire nuts, leaving extra copper, leaving extra wire. | ||
+ | #If exposed to physical damage, a wire should be protected by some type of [[Conduit|conduit]] or should be relocated. Physical damage can result from contact from persons, animals or the enviroment. | ||
+ | #All wires should have extra length left in [[Junction box|junction boxes]] or at any point where a connection is made. This serves many important purposes: | ||
+ | ::*To prevent damage from the accidental contact with a person that may move the wire. An overly tight wire exposed to tension may immediately break free from its connection and cause a fault or fire. | ||
+ | ::*To allow for expansion and contraction of wire and conduit resulting from heating and cooling. | ||
+ | ::*To provide extra wire that enables safe working conditions in the future. | ||
+ | #All connections made with wire should be done with some kind of mechanical connection, like a wirenut, [[Busbar|busbar]] or [[Module connectors|PV module connector]]. Connections performed solely with electrical tape - as is common practice in many parts of the world - are far more likely to fail and cause issues. | ||
+ | #All wires that are entering a connection (busbar, should leave some copper exposed to ensure that insulation is not entering the connection. Insulation in a connection can create resistance, heat and ultimately a fire. |
Revision as of 10:39, 3 November 2020
Wire nuts, leaving extra copper, leaving extra wire.
- If exposed to physical damage, a wire should be protected by some type of conduit or should be relocated. Physical damage can result from contact from persons, animals or the enviroment.
- All wires should have extra length left in junction boxes or at any point where a connection is made. This serves many important purposes:
- To prevent damage from the accidental contact with a person that may move the wire. An overly tight wire exposed to tension may immediately break free from its connection and cause a fault or fire.
- To allow for expansion and contraction of wire and conduit resulting from heating and cooling.
- To provide extra wire that enables safe working conditions in the future.
- All connections made with wire should be done with some kind of mechanical connection, like a wirenut, busbar or PV module connector. Connections performed solely with electrical tape - as is common practice in many parts of the world - are far more likely to fail and cause issues.
- All wires that are entering a connection (busbar, should leave some copper exposed to ensure that insulation is not entering the connection. Insulation in a connection can create resistance, heat and ultimately a fire.