Line 5: Line 5:
 
#Ask questions of anyone who has been using the system: When did the issue start? What was the weather like around that time? How was the system being used when the issue first appeared - time of day? what lights/appliances were on? Had any changes been made to the system or had the way in which the system is used changed like a new appliance or adding a new circuit? Was the battery bank [[Energy storage|depth of discharge (DoD)]] staying within appropriate guidelines recently?
 
#Ask questions of anyone who has been using the system: When did the issue start? What was the weather like around that time? How was the system being used when the issue first appeared - time of day? what lights/appliances were on? Had any changes been made to the system or had the way in which the system is used changed like a new appliance or adding a new circuit? Was the battery bank [[Energy storage|depth of discharge (DoD)]] staying within appropriate guidelines recently?
 
#Any system that is undergoing troubleshooting should follow safety guidelines and best practices outlined in [[Electrical safety]]. All people in the vicinity should be notified that you are beginning to work on the system and all power sources should be [[Electrical safety#Lock out, tag out|locked out and tagged out]].  
 
#Any system that is undergoing troubleshooting should follow safety guidelines and best practices outlined in [[Electrical safety]]. All people in the vicinity should be notified that you are beginning to work on the system and all power sources should be [[Electrical safety#Lock out, tag out|locked out and tagged out]].  
#When taking any measurements or evaluating any part of the system, it is vital to ask beforehand: what is the expected result if the system were functioning properly?  
+
#Use a [[Multimeter|multimeter]] properly. When taking any measurements or evaluating any part of the system, it is vital to ask beforehand: what would be expected if the system were functioning properly? Compare the result that your result and consider carefully if the two vary.
 
#Methodically examine the system. Check different combinations of components and circuits. Disconnect particular circuits. Check components in isolation. Write down your results if it is a particularly complex system. This will help narrow down the component or circuit that is causing the issue.
 
#Methodically examine the system. Check different combinations of components and circuits. Disconnect particular circuits. Check components in isolation. Write down your results if it is a particularly complex system. This will help narrow down the component or circuit that is causing the issue.
 
#It is often necessary when troubleshooting to energize (turn on) certain parts of a system in order to be able to check voltages and if they are functioning properly in isolation. This should be done very carefully and only by someone who has sufficient knowledge and understanding of off-grid PV systems.
 
#It is often necessary when troubleshooting to energize (turn on) certain parts of a system in order to be able to check voltages and if they are functioning properly in isolation. This should be done very carefully and only by someone who has sufficient knowledge and understanding of off-grid PV systems.

Revision as of 08:37, 3 November 2020

Off-grid PV systems are complex systems with many different components that must function together perfectly in order for the system to be able to provide power to end-users. An issue in the system design, installation or component manufacturing will typically not become apparent until the system begins to malfunction. Often times with simple off-grid PV systems an error is readily identified, like a dead battery bank in a system that was installed 5 years beforehand. Other times it can be quite complicated to identify what is causing the problem because an issue may only occurr intermittently under certain exact conditions that must be identified or a problem may manifest itself in one component - like the inverter shutting down - but actually be the result of a battery bank with a low voltage because the PV array is not functioning properly. It is important to understand all of the different components and consider how they interact as a system in order to properly perform a troubleshooting process. The complexity of an off-grid PV system and the fact that it is a system that involves electricity mean that any approach to identifying and solving a problem must be done systematically and with caution. A system that has an unidentified issue should be treated with extra precaution as the system has a failing component, installation error or a ground fault, which can create various unanticipated hazards.

  1. Before touching any part of the system, perform a visual inspection: Does everything look like it is properly connected and installed? Does anything appear burnt or smell strange? Has electrolyte spilled out of flooded lead acid batteries? Are any error or warning lights blinking on the equipment?
  2. Ask questions of anyone who has been using the system: When did the issue start? What was the weather like around that time? How was the system being used when the issue first appeared - time of day? what lights/appliances were on? Had any changes been made to the system or had the way in which the system is used changed like a new appliance or adding a new circuit? Was the battery bank depth of discharge (DoD) staying within appropriate guidelines recently?
  3. Any system that is undergoing troubleshooting should follow safety guidelines and best practices outlined in Electrical safety. All people in the vicinity should be notified that you are beginning to work on the system and all power sources should be locked out and tagged out.
  4. Use a multimeter properly. When taking any measurements or evaluating any part of the system, it is vital to ask beforehand: what would be expected if the system were functioning properly? Compare the result that your result and consider carefully if the two vary.
  5. Methodically examine the system. Check different combinations of components and circuits. Disconnect particular circuits. Check components in isolation. Write down your results if it is a particularly complex system. This will help narrow down the component or circuit that is causing the issue.
  6. It is often necessary when troubleshooting to energize (turn on) certain parts of a system in order to be able to check voltages and if they are functioning properly in isolation. This should be done very carefully and only by someone who has sufficient knowledge and understanding of off-grid PV systems.