Difference between revisions of "Translations:Shading/6/en"

From Open Source Solar Project
Jump to navigation Jump to search
(Importing a new version from external source)
 
(Importing a new version from external source)
 
Line 1: Line 1:
The cells of a PV module are connected in series. If one part of a part of a series circuit has high resistance or is not performing properly, it becomes a constraint for all of the other parts of the circuit. PV modules have incorporated ''bypass diodes'' in their junction boxes which automatically bypass strings of cells that are not performing properly. The current from other modules or other cells within the module will simply bypass the poorly functioning columns. The typical PV module only has three different strings of PV cells, connected along the long axis of the module, with each one having its own bypass diode. This has important consequences for how a PV module performs when there is shade as bypass diodes respond variably depending upon the conditions. Shading along the short-axis (rows) of the module will have a greater impact than shading along the long-axis (columns) of the module
+
The cells of a PV module are connected in series. If one part of a series circuit has high resistance or is not performing properly, it becomes a constraint for all of the other parts of the circuit. PV modules have incorporated ''bypass diodes'' in their junction boxes which automatically bypass strings of cells that are not performing properly. The current from other modules or other cells within the module will simply bypass the poorly functioning columns. The typical PV module only has three different strings of PV cells, connected along the long axis of the module, with each one having its own bypass diode. This has important consequences for how a PV module performs when there is shade as bypass diodes respond variably depending upon the conditions. Shading along the short-axis (rows) of the module will have a greater impact than shading along the long-axis (columns) of the module.

Latest revision as of 13:57, 10 February 2021

Information about message (contribute)
This message has no documentation. If you know where or how this message is used, you can help other translators by adding documentation to this message.
Message definition (Shading)
The cells of a PV module are connected in series. If one part of a series circuit has high resistance or is not performing properly, it becomes a constraint for all of the other parts of the circuit. PV modules have incorporated ''bypass diodes'' in their junction boxes which automatically bypass strings of cells that are not performing properly. The current from other modules or other cells within the module will simply bypass the poorly functioning columns. The typical PV module only has three different strings of PV cells, connected along the long axis of the module, with each one having its own bypass diode. This has important consequences for how a PV module performs when there is shade as bypass diodes respond variably depending upon the conditions. Shading along the short-axis (rows) of the module will have a greater impact than shading along the long-axis (columns) of the module.
TranslationThe cells of a PV module are connected in series. If one part of a series circuit has high resistance or is not performing properly, it becomes a constraint for all of the other parts of the circuit. PV modules have incorporated ''bypass diodes'' in their junction boxes which automatically bypass strings of cells that are not performing properly. The current from other modules or other cells within the module will simply bypass the poorly functioning columns. The typical PV module only has three different strings of PV cells, connected along the long axis of the module, with each one having its own bypass diode. This has important consequences for how a PV module performs when there is shade as bypass diodes respond variably depending upon the conditions. Shading along the short-axis (rows) of the module will have a greater impact than shading along the long-axis (columns) of the module.

The cells of a PV module are connected in series. If one part of a series circuit has high resistance or is not performing properly, it becomes a constraint for all of the other parts of the circuit. PV modules have incorporated bypass diodes in their junction boxes which automatically bypass strings of cells that are not performing properly. The current from other modules or other cells within the module will simply bypass the poorly functioning columns. The typical PV module only has three different strings of PV cells, connected along the long axis of the module, with each one having its own bypass diode. This has important consequences for how a PV module performs when there is shade as bypass diodes respond variably depending upon the conditions. Shading along the short-axis (rows) of the module will have a greater impact than shading along the long-axis (columns) of the module.