Difference between revisions of "Simplified load evaluation"
Line 4: | Line 4: | ||
When designing any system, it is almost always necessary to explore various different designs with varying loads and usage patterns to arrive at the best balance between cost and budget. | When designing any system, it is almost always necessary to explore various different designs with varying loads and usage patterns to arrive at the best balance between cost and budget. | ||
− | + | '''Additional considerations:''' | |
*If a system includes a refrigerator, it is necessary to follow the [[:Category:Detailed system design|detailed system design process]] to properly account for [[Duty cycle|duty cycle]]. | *If a system includes a refrigerator, it is necessary to follow the [[:Category:Detailed system design|detailed system design process]] to properly account for [[Duty cycle|duty cycle]]. | ||
*The make, model, and power rating of any loads currently present at the site should be documented. Photos are very useful. | *The make, model, and power rating of any loads currently present at the site should be documented. Photos are very useful. | ||
Line 121: | Line 121: | ||
==AC load evaluation== | ==AC load evaluation== | ||
− | There are additional considerations that go into performing an AC load analysis because this analysis is used for [[Inverter sizing and selection|inverter sizing and selection]], as well as [[PV source and charge controller sizing and selection]] and [[Energy storage sizing and selection|Energy storage sizing and selection]]. | + | There are additional considerations that go into performing an AC load analysis because this analysis is used for [[Inverter sizing and selection|inverter sizing and selection]], as well as [[PV source and charge controller sizing and selection]] and [[Energy storage sizing and selection|Energy storage sizing and selection]]. |
− | |||
− | |||
− | |||
− | ====Step 1: | + | ====Step 1: Fill out AC load chart==== |
− | |||
{| class="wikitable" style="text-align: center;" | {| class="wikitable" style="text-align: center;" | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
!# | !# | ||
!Load | !Load | ||
Line 155: | Line 131: | ||
!Watts | !Watts | ||
!Total watts | !Total watts | ||
− | |||
− | |||
− | |||
− | |||
− | |||
!Hours per day | !Hours per day | ||
− | |||
− | |||
− | |||
− | |||
!Average daily AC watt-hours | !Average daily AC watt-hours | ||
|- | |- | ||
|1 | |1 | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
| | | | ||
| | | | ||
Line 185: | Line 143: | ||
|- | |- | ||
|2 | |2 | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
| | | | ||
| | | | ||
Line 202: | Line 151: | ||
|- | |- | ||
|3 | |3 | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
| | | | ||
| | | | ||
Line 219: | Line 159: | ||
|- | |- | ||
|4 | |4 | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
| | | | ||
| | | | ||
Line 236: | Line 167: | ||
|- | |- | ||
|5 | |5 | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
| | | | ||
| | | | ||
Line 253: | Line 175: | ||
|- | |- | ||
|6 | |6 | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
| | | | ||
| | | | ||
Line 269: | Line 182: | ||
|- | |- | ||
|7 | |7 | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
| | | | ||
| | | | ||
Line 286: | Line 190: | ||
|- | |- | ||
|8 | |8 | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
| | | | ||
| | | | ||
Line 303: | Line 198: | ||
|- | |- | ||
|9 | |9 | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
| | | | ||
| | | | ||
Line 320: | Line 206: | ||
|- | |- | ||
|10 | |10 | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
| | | | ||
| | | | ||
Line 340: | Line 217: | ||
*'''Quantity:''' The number of the particular load. | *'''Quantity:''' The number of the particular load. | ||
*'''Watts:''' The power rating in watts for the load. | *'''Watts:''' The power rating in watts for the load. | ||
− | *'''Total watts =''' Quantity × | + | *'''Total watts =''' Quantity × watts |
− | |||
− | |||
− | |||
− | |||
*'''Hours per day:''' The maximum number of hours the load(s) will be operated per day. If the load has a duty cycle 24 hours should be used. | *'''Hours per day:''' The maximum number of hours the load(s) will be operated per day. If the load has a duty cycle 24 hours should be used. | ||
*'''Days per week:''' The maximum number of days the load(s) will be operated per week. | *'''Days per week:''' The maximum number of days the load(s) will be operated per week. | ||
− | *'''Average daily AC Watt-hours =''' Total watts × Duty cycle | + | *'''Average daily AC Watt-hours =''' Total watts × Duty cycle × Hours per day |
====Step 3: Deteremine AC energy demand==== | ====Step 3: Deteremine AC energy demand==== | ||
+ | The total energy demand for all loads must be added up and then it must be multiplied by the average efficiency of the inverter to determine the actual total energy requirement. Inverter efficiency should be assumed to be .85 (85%). Some inverters will list higher peak efficiencies, but they will not achieve that level of efficiency under normal usage. | ||
{| class="wikitable" border=1 style="width: 80%;" | {| class="wikitable" border=1 style="width: 80%;" | ||
− | ! style="width: 20%"| | + | ! style="width: 20%"|Sum average daily AC watt-hours |
− | ! style="text-align:left;"| = sum of Average daily AC watt-hours for all loads | + | ! style="text-align:left;"| = sum of Average daily AC watt-hours for all loads |
|} | |} | ||
{| class="wikitable" border=1 style="width: 80%;" | {| class="wikitable" border=1 style="width: 80%;" | ||
− | ! style="width: 20%"|Total average daily AC watt-hours | + | ! style="width: 20%"|Total average daily AC watt-hours |
− | ! style="text-align:left;"| = sum of Average daily AC watt-hours | + | ! style="text-align:left;"| = sum of Average daily AC watt-hours ÷ .85 |
|} | |} | ||
====Step 4: Determine AC power demand==== | ====Step 4: Determine AC power demand==== | ||
{| class="wikitable" border=1 style="width: 80%;" | {| class="wikitable" border=1 style="width: 80%;" | ||
− | ! style="width: 20%"|Total | + | ! style="width: 20%"|Total connected watts |
− | ! style="text-align:left;"| = sum of | + | ! style="text-align:left;"| = sum of Total watts |
− | |||
− | |||
− | |||
− | |||
− | |||
|} | |} | ||
Line 376: | Line 245: | ||
{| class="wikitable" border=1 style="width: 80%;" | {| class="wikitable" border=1 style="width: 80%;" | ||
− | ! style="width: 20%"|Average daily watt-hours required | + | ! style="width: 20%"|Average daily watt-hours required |
− | ! style="text-align:left;"| = Total average daily DC watt-hours | + | ! style="text-align:left;"| = Total average daily DC watt-hours + Total average daily AC watt-hours |
− | |||
− | |||
− | |||
− | |||
− | |||
|} | |} |
Revision as of 07:02, 19 January 2021
The load evaluation involves gathering information on loads which will serve as the basis for the rest of the system design process. Power ratings and usage estimates for necessary and potential loads are gathered into a table - one for direct current and one for alternating current. It is important to use maximum values for estimated usage to ensure that the system is adequately sized. If a system has extreme solar resource or load usage differences throughout the year, then it may be necessary to perform a load and solar resource comparison from the detailed design process.
When designing any system, it is almost always necessary to explore various different designs with varying loads and usage patterns to arrive at the best balance between cost and budget.
Additional considerations:
- If a system includes a refrigerator, it is necessary to follow the detailed system design process to properly account for duty cycle.
- The make, model, and power rating of any loads currently present at the site should be documented. Photos are very useful.
- If the system design is going to incorporate loads that have not yet been purchased, guidance should be provided about the value and importance of purchasing energy efficient loads.
- This process can be difficult in locations that do not currently have electricity or that have users that do not have experience with electricity beforehand. In these cases, there is a tendency to over-estimate and under-estimate appliance usage depending on the individual. The result is that more responsibility falls upon the person performing the load evaluation and the system designer to provide guidance and accurate estimates.
- Potential projects that do not currently have an electrical system will also require additional evaluation and design work to ensure that the building will have adequate outlets for (power receptacles) and lighting for the intended use of each room.
Contents
DC load evaluation
Typical direct current loads include lights, cell phones, and radios. If a system incorporates an inverter, it is important that its idle consumption is included in the DC load evaluation.
Step 1: Fill out DC load chart
# | Load | Quantity | Watts | Total watts | Hours per day | Average daily DC watt-hours |
---|---|---|---|---|---|---|
1 | ||||||
2 | ||||||
3 | ||||||
4 | ||||||
5 | ||||||
6 | ||||||
7 | ||||||
8 | ||||||
9 | ||||||
10 |
- Load: The make and model or type of load.
- Quantity: The number of the particular load.
- Watts: The power rating in watts of the load.
- Total watts = Quantity × Watts
- Hours per day: The maximum number of hours the load(s) will be operated per day.
- Average daily DC watt-hours = Total watts × Hours per day
Step 2: Determine DC energy demand
Total average daily DC watt-hours | = sum of Average daily DC watt-hours for all loads |
---|
AC load evaluation
There are additional considerations that go into performing an AC load analysis because this analysis is used for inverter sizing and selection, as well as PV source and charge controller sizing and selection and Energy storage sizing and selection.
Step 1: Fill out AC load chart
# | Load | Quantity | Watts | Total watts | Hours per day | Average daily AC watt-hours |
---|---|---|---|---|---|---|
1 | ||||||
2 | ||||||
3 | ||||||
4 | ||||||
5 | ||||||
6 | ||||||
7 | ||||||
8 | ||||||
9 | ||||||
10 |
- Load: The make and model or type of load.
- Quantity: The number of the particular load.
- Watts: The power rating in watts for the load.
- Total watts = Quantity × watts
- Hours per day: The maximum number of hours the load(s) will be operated per day. If the load has a duty cycle 24 hours should be used.
- Days per week: The maximum number of days the load(s) will be operated per week.
- Average daily AC Watt-hours = Total watts × Duty cycle × Hours per day
Step 3: Deteremine AC energy demand
The total energy demand for all loads must be added up and then it must be multiplied by the average efficiency of the inverter to determine the actual total energy requirement. Inverter efficiency should be assumed to be .85 (85%). Some inverters will list higher peak efficiencies, but they will not achieve that level of efficiency under normal usage.
Sum average daily AC watt-hours | = sum of Average daily AC watt-hours for all loads |
---|
Total average daily AC watt-hours | = sum of Average daily AC watt-hours ÷ .85 |
---|
Step 4: Determine AC power demand
Total connected watts | = sum of Total watts |
---|
Total average daily energy demand
The total energy demand for the system is the added Average daily DC-watt hours and Average daily AC watt-hours for each time period.
Average daily watt-hours required | = Total average daily DC watt-hours + Total average daily AC watt-hours |
---|