*Design daily watt-hours required | *Design daily watt-hours required | ||
− | ====Step 1: Determine monthly ratio of | + | ====Step 1: Determine monthly ratio of energy demand to solar resource==== |
{| class="wikitable" border=1 | {| class="wikitable" border=1 | ||
!Month | !Month | ||
− | ![[Weather and solar resource evaluation#Solar resource (insolation)|Average | + | ![[Weather and solar resource evaluation#Solar resource (insolation)|Average monthly insolation]] |
− | ![[Load evaluation#Total average daily energy demand|Total average daily energy demand] | + | ![[Load evaluation#Total average daily energy demand|Total average daily energy demand]] |
!Ratio | !Ratio | ||
|- | |- | ||
Line 74: | Line 74: | ||
|} | |} | ||
*'''Month:''' The month of the year. | *'''Month:''' The month of the year. | ||
− | *'''Average | + | *'''Average monthly insolation:''' Solar resource data obtained for the location from [[Weather and solar resource data sources]]. |
*'''[[Load evaluation#Total average daily energy demand|Total average daily energy demand]]''' for the month from the load evaluation. | *'''[[Load evaluation#Total average daily energy demand|Total average daily energy demand]]''' for the month from the load evaluation. | ||
− | *'''Ratio =''' | + | *'''Ratio =''' Total average daily energy demand ÷ Average monthly insolation |
====Step 2: Determine design values==== | ====Step 2: Determine design values==== | ||
Line 87: | Line 87: | ||
{| class="wikitable" border=1 style="width: 80%;" | {| class="wikitable" border=1 style="width: 80%;" | ||
! style="width: 20%"|Design daily watt-hours required | ! style="width: 20%"|Design daily watt-hours required | ||
− | ! style="text-align:left;"| = | + | ! style="text-align:left;"| = Total average daily energy demand from month with the highest ratio |
|} | |} | ||
==Notes/references== | ==Notes/references== | ||
<references/> | <references/> |
Revision as of 16:53, 4 January 2021
The design process for an off-grid PV system should use conservative, worst-case values to ensure that the system is capable of meeting the energy needs of users throughout the year. There are many locations that have a significant seasonal variance in solar resource due to poor weather or latitude. Many off-grid PV systems will see a significant variance in how loads are used throughout the year, especially in locations that are only seasonally occupied. These two different factors - load usage vs. solar resource - make it important to determine what month to use in the system design as the worst-case scenario. An analysis of loads and usage could be performed on a monthly basis, but the most drastic shift in usage likely occurs between the major seasons in a given region meaning two times per year. Determining the worst-case month can be done using a simple table and a quick calculation using monthly insolation data and Average daily Wh estimates for the two different time periods October - March and April - September. The values and calculation can be performed in Wh or kWh - the ratio is what is important. The two following values used for the design should be chosen from the month with the highest ratio of average daily watt-hours relative to average monthly insolation:
- Design daily insolation
- Design daily watt-hours required
Step 1: Determine monthly ratio of energy demand to solar resource
Month | Average monthly insolation | Total average daily energy demand | Ratio |
---|---|---|---|
January | |||
February | |||
March | |||
April | |||
May | |||
June | |||
July | |||
August | |||
September | |||
October | |||
November | |||
December |
- Month: The month of the year.
- Average monthly insolation: Solar resource data obtained for the location from Weather and solar resource data sources.
- Total average daily energy demand for the month from the load evaluation.
- Ratio = Total average daily energy demand ÷ Average monthly insolation
Step 2: Determine design values
Design daily insolation | = Average monthly insolation from month with the highest ratio ÷ 30 |
---|
Design daily watt-hours required | = Total average daily energy demand from month with the highest ratio |
---|