Difference between revisions of "Detailed AC system design"
Jump to navigation
Jump to search
(Created page with "{| class="wikitable" style="text-align: center;" !|Inverter efficiency |.85 |} {| class="wikitable" style="text-align: center;" !# !Load !Quantity !Watts !Total watts !Duty...") |
|||
Line 158: | Line 158: | ||
| | | | ||
|- style="background-color:#ADD8E6;" | |- style="background-color:#ADD8E6;" | ||
− | |colspan="12"|'''Total average daily AC | + | |colspan="12"|'''Total average daily AC watt-hours''' |
|'''95 Wh''' | |'''95 Wh''' | ||
|- style="background-color:#ADD8E6;" | |- style="background-color:#ADD8E6;" | ||
Line 177: | Line 177: | ||
*'''Hours per day:''' The maximum number of hours the load(s) will be operated per day. If the load has a duty cycle 24 hours should be used. | *'''Hours per day:''' The maximum number of hours the load(s) will be operated per day. If the load has a duty cycle 24 hours should be used. | ||
*'''Days per week:''' The maximum number of days the load(s) will be operated per week. | *'''Days per week:''' The maximum number of days the load(s) will be operated per week. | ||
− | *'''Average daily AC | + | *'''Average daily AC watt-hours =''' Total watts × Duty cycle ÷ Inverter efficiency × Hours per day × Days per week ÷ 7 days |
− | *'''Total average daily AC | + | *'''Total average daily AC watt-hours =''' sum of Average daily AC watt-hours for all loads |
− | *'''Total VA =''' sum of | + | *'''Total VA =''' sum of volt-amperes (VA) |
*'''Total VA with surge watts =''' sum of Surge watts for all loads + Total VA | *'''Total VA with surge watts =''' sum of Surge watts for all loads + Total VA |
Revision as of 16:59, 7 December 2020
Inverter efficiency | .85 |
---|
# | Load | Quantity | Watts | Total watts | Duty cycle | Surge factor | Surge Watts | Power factor | Volt-amperes (VA) | Hours per day | Days per week | Average daily AC watt-hours |
---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | Generic laptop | 1 | 15 W | 15 W | 1 | 0 | 0W | .45 | 33 VA | 4 hours | 30 days | 71 Wh |
2 | Generic cell phone | 2 | 5 W | 10 W | 1 | 0 | 0 W | .5 | 20 VA | 1 hour | 30 days | 12 Wh |
3 | Generic blender | 1 | 600 W | 600 W | 1 | 3 | 1800 W | .8 | 706 VA | .05 hour | 10 days | 12 Wh |
4 | ||||||||||||
5 | ||||||||||||
6 | ||||||||||||
7 | ||||||||||||
8 | ||||||||||||
9 | ||||||||||||
10 | ||||||||||||
Total average daily AC watt-hours | 95 Wh | |||||||||||
Total VA | 759 VA | |||||||||||
Total VA with surge watts | 2559 W |
- Load: The make and model or type of load.
- Quantity: The number of of that particular load.
- Watts: The power rating in watts for the load.
- Total watts = quantity × watts
- Duty cycle = Rated or estimated duty cycle for the load. If the load has no duty cycle a value of 0 should be used. A load with a duty cycle of 20% would be inputted as .2
- Surge factor = Rated or estimated duty cycle for the load. If the load does not have a surge requirement a value of 1 should be used. Common values are between 3-5.
- Power factor = Rated or estimated power factor for the load.
- Volt-amperes (VA) = Total watts ÷ Power factor
- Hours per day: The maximum number of hours the load(s) will be operated per day. If the load has a duty cycle 24 hours should be used.
- Days per week: The maximum number of days the load(s) will be operated per week.
- Average daily AC watt-hours = Total watts × Duty cycle ÷ Inverter efficiency × Hours per day × Days per week ÷ 7 days
- Total average daily AC watt-hours = sum of Average daily AC watt-hours for all loads
- Total VA = sum of volt-amperes (VA)
- Total VA with surge watts = sum of Surge watts for all loads + Total VA