A disconnect enables a circuit to be disconnected or isolated from the rest of an electrical system. Disconnects are vital for safety and security as they allow different components in the system to be isolated in order to perform maintenance or service. In an offgrid PV system there are two power sources - the [[Solar PV module|PV source]] and the [[Energy storage|energy storage system]] - that do not have an integrated means to disconnect or turn them off. All major components in a PV system should have a disconnect that enables them to be isolated from these two potential power sources and any others. In an offgrid PV system breakers are typically used as a disconnect - as they can be opened under load - while also serving as an OCPD for system components. Fuses are not an appropriate disconnect as they should not be opened under load. There are disconnects that can integrate fusing for locations where a breaker is not the best option.
+
A disconnect enables a circuit to be disconnected or isolated from the rest of an electrical system. Disconnects are vital for safety and security as they allow different components in the system to be isolated in order to perform maintenance or service. Traditional disconnects, like in the image, come in countless different sizes and configurations, including custom-built configurations. Although they are not often used in small-scale offgrid installations as most disconnecting needs can be met with breakers, fuse holders, or module connectors which are cheaper and simpler. A traditional disconnect must be rated for the proper current (AC or DC), maximum voltage and maximum current of the circuit. Disconnects can also be found that incorporate fuses for suitable applications.
 +
 
 +
The appropriate type of disconnect for a circuit depends upon the type of circuit - there are two different types of disconnects that are required in an offgrid PV system.
 +
 
 +
==Power source disconnects==
 +
[[File:Disconnects.png|thumb|right|'''Required disconnect in a PV system:'''<br/> 1. PV module equipment disconnects 2. PV power source disconnect 3. Charge controller equipment disconnect 4. Energy storage power source disconnect 5. Inverter equipment disconnect]]
 +
Power source disconnects enable the isolation of any potential power source, including while under load (while current is flowing) in case of emergency. In an offgrid PV system there are two power sources - the [[Solar PV module|PV source]] and the [[Energy storage|energy storage system]] - that meet this requirement. If a system incorporates a generator then it will also require a seperate disconnect. For offgrid PV systems, breakers are typically used as power source disconnects as they can fulfill the role of an OCPD at the same time, although a properly sized (suitable for DC, correct voltage, correct current) traditional disconnect would work just fine. Any power source disconnect must be rated to disconnect a circuit with current flowing, therefore fuse holders or any type of connector cannot qualify as a power source disconnect as they cannot be opened under load.
 +
 
 +
==Equipment disconnects==
 +
All major components in a PV system should have a disconnect that enables them to be isolated from these two potential power sources or any others, although for equipment that is not a power source, it is not necessary that an equipment disconnect be able to function under load. Therefore, touch safe fuse holders and connector - like MC4 connectors on PV modules - can qualify as equipment disconnects. It is necessary to have a power source disconnect that makes it possible to stop any current from flowing if using an equipment disconnect that is not rated for use under load.

Revision as of 13:06, 23 October 2020

An example of a traditional disconnect. The red handle moves the red cylinder in the center to connect and disconnect the line (top) and load (bottom) terminals of the disconnect.

A disconnect enables a circuit to be disconnected or isolated from the rest of an electrical system. Disconnects are vital for safety and security as they allow different components in the system to be isolated in order to perform maintenance or service. Traditional disconnects, like in the image, come in countless different sizes and configurations, including custom-built configurations. Although they are not often used in small-scale offgrid installations as most disconnecting needs can be met with breakers, fuse holders, or module connectors which are cheaper and simpler. A traditional disconnect must be rated for the proper current (AC or DC), maximum voltage and maximum current of the circuit. Disconnects can also be found that incorporate fuses for suitable applications.

The appropriate type of disconnect for a circuit depends upon the type of circuit - there are two different types of disconnects that are required in an offgrid PV system.

Power source disconnects

Required disconnect in a PV system:
1. PV module equipment disconnects 2. PV power source disconnect 3. Charge controller equipment disconnect 4. Energy storage power source disconnect 5. Inverter equipment disconnect

Power source disconnects enable the isolation of any potential power source, including while under load (while current is flowing) in case of emergency. In an offgrid PV system there are two power sources - the PV source and the energy storage system - that meet this requirement. If a system incorporates a generator then it will also require a seperate disconnect. For offgrid PV systems, breakers are typically used as power source disconnects as they can fulfill the role of an OCPD at the same time, although a properly sized (suitable for DC, correct voltage, correct current) traditional disconnect would work just fine. Any power source disconnect must be rated to disconnect a circuit with current flowing, therefore fuse holders or any type of connector cannot qualify as a power source disconnect as they cannot be opened under load.

Equipment disconnects

All major components in a PV system should have a disconnect that enables them to be isolated from these two potential power sources or any others, although for equipment that is not a power source, it is not necessary that an equipment disconnect be able to function under load. Therefore, touch safe fuse holders and connector - like MC4 connectors on PV modules - can qualify as equipment disconnects. It is necessary to have a power source disconnect that makes it possible to stop any current from flowing if using an equipment disconnect that is not rated for use under load.