− | A [[Special:MyLanguage/Charge controller#Charge controller types|MPPT charge controller]] is rated to operate at a particular [[Special:MyLanguage/DC system voltage|DC system voltage]], maximum current and maximum voltage. MPPT charge controllers can charge the battery bank with any [[Special:MyLanguage/Series and parallel connections|series and parallel]] configuration of modules that doesn't exceed the maximum voltage and maximum current or drop below the required charging voltage of the [[Special:MyLanguage/Energy storage|energy storage system]]. Exceeding the voltage rating of an MPPT due to cold temperatures | + | A [[Special:MyLanguage/Charge controller#Charge controller types|MPPT charge controller]] is rated to operate at a particular [[Special:MyLanguage/DC system voltage|DC system voltage]], maximum current and maximum voltage. MPPT charge controllers can charge the battery bank with any [[Special:MyLanguage/Series and parallel connections|series and parallel]] configuration of modules that doesn't exceed the maximum voltage and maximum current or drop below the required charging voltage of the [[Special:MyLanguage/Energy storage|energy storage system]]. Exceeding the voltage rating of an MPPT due to cold temperatures can damage it. Many charge controllers allow the current rating to be exceeded to a certain point without damage, just lost energy - it depends on the charge controller. There are several important calculations that must be performed to properly size an MPPT charge controller: |
Latest revision as of 18:02, 6 April 2021
A MPPT charge controller is rated to operate at a particular DC system voltage, maximum current and maximum voltage. MPPT charge controllers can charge the battery bank with any series and parallel configuration of modules that doesn't exceed the maximum voltage and maximum current or drop below the required charging voltage of the energy storage system. Exceeding the voltage rating of an MPPT due to cold temperatures can damage it. Many charge controllers allow the current rating to be exceeded to a certain point without damage, just lost energy - it depends on the charge controller. There are several important calculations that must be performed to properly size an MPPT charge controller: