All inverters are rated based upon the amount of power or volts/amps that they can continuously supply. In addition to this continuous rating an inverter will be able to supply higher amounts of power for brief periods of time in order to supply loads that require momentary surges of more current when starting. These additional ratings may come in 30 minute, 5 minute, 1 minute, 30 second, 10 second or 1 second ratings. All loads and their energy requirements will need to be evaluated to select the appropriate inverter - see [[:Category:Inverter sizing and selection|inverter sizing and selection]] for more information.
+
All inverters are rated based upon the amount of power that they can continuously supply in watts or volt-amperes. In addition to this continuous rating an inverter will be able to supply higher amounts of power for brief periods of time in order to supply loads that require momentary surges of more current when starting. These additional ratings may come in 30 minute, 5 minute, 1 minute, 30 second, 10 second or 1 second ratings. All loads and their energy requirements will need to be evaluated to select the appropriate inverter - see [[Special:MyLanguage/Inverter sizing and selection|inverter sizing and selection]] for more information.

Latest revision as of 18:16, 11 February 2021

Information about message (contribute)
This message has no documentation. If you know where or how this message is used, you can help other translators by adding documentation to this message.
Message definition (Inverter)
All inverters are rated based upon the amount of power that they can continuously supply in watts or volt-amperes. In addition to this continuous rating an inverter will be able to supply higher amounts of power for brief periods of time in order to supply loads that require momentary surges of more current when starting. These additional ratings may come in 30 minute, 5 minute, 1 minute, 30 second, 10 second or 1 second ratings. All loads and their energy requirements will need to be evaluated to select the appropriate inverter - see [[Special:MyLanguage/Inverter sizing and selection|inverter sizing and selection]] for more information.
TranslationAll inverters are rated based upon the amount of power that they can continuously supply in watts or volt-amperes. In addition to this continuous rating an inverter will be able to supply higher amounts of power for brief periods of time in order to supply loads that require momentary surges of more current when starting. These additional ratings may come in 30 minute, 5 minute, 1 minute, 30 second, 10 second or 1 second ratings. All loads and their energy requirements will need to be evaluated to select the appropriate inverter - see [[Special:MyLanguage/Inverter sizing and selection|inverter sizing and selection]] for more information.

All inverters are rated based upon the amount of power that they can continuously supply in watts or volt-amperes. In addition to this continuous rating an inverter will be able to supply higher amounts of power for brief periods of time in order to supply loads that require momentary surges of more current when starting. These additional ratings may come in 30 minute, 5 minute, 1 minute, 30 second, 10 second or 1 second ratings. All loads and their energy requirements will need to be evaluated to select the appropriate inverter - see inverter sizing and selection for more information.