Difference between revisions of "Distribution panel"
m (Text replacement - "[[Types of electricity" to "[[Electricity types") |
(Marked this version for translation) |
||
(6 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
[[Category:Power distribution]] | [[Category:Power distribution]] | ||
− | [[File:Distributionpanel201105.png|thumb|right|'''Example of a distribution panel or load center:'''<br/> ''Left -'' Cover removed showing (1) | + | <languages /> |
− | In an off-grid PV system, the power | + | <translate> |
+ | <!--T:1--> | ||
+ | [[File:Distributionpanel201105.png|thumb|right|'''Example of a distribution panel or load center:'''<br/> ''Left -'' Cover removed showing (1) Wires from the inverter or power source: L1, grounded conductor (neutral) and equipment ground. (2) Wires to a load: L1, grounded conductor (neutral) and equipment ground.<br /> ''Right -'' Distribution panel with cover.]] | ||
+ | |||
+ | <!--T:2--> | ||
+ | In an off-grid PV system, the output of a power soure - AC or DC - that will be used to supply multiple loads will typically pass through a distribution panel that will have [[Special:MyLanguage/Overcurrent protection|overcurrent protection devices]] that will allow small diameter wires to be run to outlets, lighting and other loads. There will also typically be [[Special:MyLanguage/Busbar|busbars]] for [[Special:MyLanguage/Grounding system|equipment grounding conductors]] and grounded conductors (AC neutral). A distribution panel may be a traditional distribution panel like is commonly seen in grid-connected electrical systems (as depicted in the graphic) or it may be a specifically designed for use in off-grid PV applications. They may differ in appearance, but the purpose and function is the same. A distribution panel must be suitable for the conditions in which it will be used including: | ||
+ | |||
+ | <!--T:3--> | ||
*Maximum ampacity | *Maximum ampacity | ||
*Maximum voltage | *Maximum voltage | ||
*Phases (L1, L2, L3 etc.) | *Phases (L1, L2, L3 etc.) | ||
− | *Sufficient space for necessary [[Overcurrent protection|overcurrent protection devices]]. | + | *Sufficient space for necessary [[Special:MyLanguage/Overcurrent protection|overcurrent protection devices]]. |
− | *[[Weather rating]] | + | *[[Special:MyLanguage/Weather rating|Weather rating]] |
− | *[[Equipment certification]] | + | *[[Special:MyLanguage/Equipment certification|Equipment certification]] |
+ | |||
+ | ==Notes/references== <!--T:4--> | ||
+ | |||
+ | </translate> |
Latest revision as of 09:40, 12 February 2021
In an off-grid PV system, the output of a power soure - AC or DC - that will be used to supply multiple loads will typically pass through a distribution panel that will have overcurrent protection devices that will allow small diameter wires to be run to outlets, lighting and other loads. There will also typically be busbars for equipment grounding conductors and grounded conductors (AC neutral). A distribution panel may be a traditional distribution panel like is commonly seen in grid-connected electrical systems (as depicted in the graphic) or it may be a specifically designed for use in off-grid PV applications. They may differ in appearance, but the purpose and function is the same. A distribution panel must be suitable for the conditions in which it will be used including:
- Maximum ampacity
- Maximum voltage
- Phases (L1, L2, L3 etc.)
- Sufficient space for necessary overcurrent protection devices.
- Weather rating
- Equipment certification