Difference between revisions of "Simplified MPPT charge controller sizing and selection"

From Open Source Solar Project
Jump to navigation Jump to search
 
(15 intermediate revisions by the same user not shown)
Line 1: Line 1:
 
[[Category:Simplified system design]]
 
[[Category:Simplified system design]]
A [[Charge controller#Charge controller types|MPPT charge controller]] is rated to operate at a particular [[DC system voltage]], maximum current and maximum voltage. MPPT charge controllers can charge the battery bank with any [[Series and parallel|series and parallel]] configuration of modules that doesn't exceed the maximum voltage and maximum current or drop below the required charging voltage of the [[Energy storage|energy storage system]]. Exceeding the voltage rating of an MPPT due to cold temperatures can damage it. Many charge controllers allow the current rating to be exceeded to a certain point without damage, just lost energy - it depends on the charge controller. There are several important calculations that must be performed to properly size an MPPT charge controller:
+
<languages />
*Should be sized to work with a series and parallel PV source circuit configuration of the PV source that will not damage the charge controller due to high voltages resulting from [[Weather and solar resource evaluation|low temperatures]] at the project location.
+
<translate>
*Should be sized to work with a series and parallel PV source circuit configuration of  that will still be able to properly charge the [[:Category:Energy storage|energy storage system]] under [[Weather and solar resource evaluation|high temperatures]] and as PV modules age at the project location.
+
<!--T:1-->
 +
A [[Special:MyLanguage/Charge controller#Charge controller types|MPPT charge controller]] is rated to operate at a particular [[Special:MyLanguage/DC system voltage|DC system voltage]], maximum current and maximum voltage. MPPT charge controllers can charge the battery bank with any [[Special:MyLanguage/Series and parallel connections|series and parallel]] configuration of modules that doesn't exceed the maximum voltage and maximum current or drop below the required charging voltage of the [[Special:MyLanguage/Energy storage|energy storage system]]. Exceeding the voltage rating of an MPPT due to cold temperatures that increase PV module voltage result in damage. Many charge controllers allow the current rating to be exceeded to a certain point without damage, just lost energy, but this depends on the charge controller. There are several important calculations that must be performed to properly size an MPPT charge controller:
  
 +
<!--T:2-->
 +
*Should be sized to work with a series and parallel PV source circuit configuration that will not damage the charge controller due to high voltages resulting from [[Special:MyLanguage/Weather and solar resource evaluation|low temperatures]] at the project location.
 +
 +
<!--T:3-->
 +
*Should be sized to work with a series and parallel PV source circuit configuration of  that will still be able to properly charge the [[Special:MyLanguage/Energy storage|energy storage system]] under [[Special:MyLanguage/Simplified weather and solar resource evaluation|high temperatures]] and as PV modules age.
 +
 +
<!--T:4-->
 
'''Assumptions:'''
 
'''Assumptions:'''
 +
 +
<!--T:5-->
 
*Minimum ambient temperature: -15°C
 
*Minimum ambient temperature: -15°C
 +
 +
<!--T:6-->
 
*Maximum ambient temperature: 50°C
 
*Maximum ambient temperature: 50°C
*Conservative estimates for PV module voltages are used that cover nearly all 60 and 72 cell solar modules.
 
  
====Step 1: Determine PV module power rating====
+
<!--T:7-->
 +
*Conservative estimates for PV module voltages are used that cover nearly all 60 and 72 cell PV modules.
 +
<br />
 +
 
 +
====Step 1: Determine PV module power rating==== <!--T:8-->
 +
 
 +
<!--T:9-->
 
60-cell and 72-cell modules are the most common module size used with MPPT charge controllers. They range in size from 250W - 400W+.
 
60-cell and 72-cell modules are the most common module size used with MPPT charge controllers. They range in size from 250W - 400W+.
  
====Step 2: Determine minimum number of PV modules====
+
====Step 2: Determine minimum number of PV modules==== <!--T:10-->
This calculation will give a ''minimum'' number of modules. The final array size should always be larger than this value, thus if the result of the calculation is a decimal, it should be rounded up. Different modules sizes and configurations can be explored to find the optimal design.
+
 
 +
<!--T:11-->
 +
This calculation will give a ''minimum'' number of modules. The final PV source size should always be larger than this value, thus if the result of the calculation is a decimal, it should be rounded up. Different modules sizes and configurations can be explored to find the optimal design.
 +
 
 +
<!--T:12-->
 
{| class="wikitable" border=1 style="width: 80%;"
 
{| class="wikitable" border=1 style="width: 80%;"
 
! style="width: 20%"|Minimum number of PV modules
 
! style="width: 20%"|Minimum number of PV modules
! style="text-align:left;"| = [[Simplified minimum PV source size|Minimum PV source size]] ÷ PV module power rating (Step 1)
+
! style="text-align:left;"| = [[Special:MyLanguage/Simplified minimum PV source size|Minimum PV source size]] ÷ PV module power rating (Step 1)
 
|}
 
|}
  
====Step 3: PV source power rating====
+
====Step 3: Choose MPPT charge controller and PV source series/parallel configuration==== <!--T:13-->
This calculation will give a power rating of the PV source based upon the chosen module size and the number of modules required.
+
 
{| class="wikitable" border=1 style="width: 80%;"
+
<!--T:14-->
! style="width: 20%"|PV source power rating
+
It is necessary to test various different configurations of PV modules and charge controllers to find the best configuration. The [[Special:MyLanguage/DC system voltage|DC system voltage]], number of PV modules, input voltage of the charge controller, the number of modules in series, the number of parallel circuits, and the current rating of the charge controller can all be varied to find the best design. The final PV source and charge controller configuration must meet the following requirements:
! style="text-align:left;"| = Minimum number of PV modules (Step 2) × PV module power rating (Step 1)
+
 
|}
+
<!--T:15-->
 +
<ol>
 +
<li>Have a PV source with a final power rating that is higher than the [[Special:MyLanguage/Simplified minimum PV source size|minimum PV source size]]. This can be achieved through a combination of [[Special:MyLanguage/Series and parallel connections|series and parallel connections]].</li>
 +
<li>Have PV source string voltage that does not exceed the maximum input voltage rating of the charge controller, even under extreme temperatures. This maximum input voltage rating limits the possible configurations of PV modules that can be used to reach the minimum number of PV modules calculated in Step 2. The chart below gives maximum and minimum numbers of PV modules in series per PV source circuit for 60 and 72 cell modules. All of the PV source circuits must have the same number of PV modules if there is a single charge controller or else it will not function properly (the number of modules in series therefore must divide evenly into the minimum number of PV modules required). If there are multiple charge controllers, then the number of modules connected in series per PV source circuit should be the same for each one.
 +
 
 +
<!--T:16-->
 +
As long as the voltage doesn't exceed the rating of the charge controller(s), more PV modules per PV source circuit is generally preferable as it permits the use of smaller wires and minimizes voltage drop.</li>
 +
 
 +
<!--T:17-->
 +
[[File:Mpptseriesparallel.png|frameless]]
  
====Step 4: Determine minimum MPPT charge controller current rating====
 
An MPPT charge controller is capable of of accepting varying voltages from the array and converting them into current at the proper charging voltage for the [[Energy storage|energy storage system]]. The maximum current of the PV source can be calculated by dividing the power rating of the [[PV module|PV source]] by the [[DC system voltage]] as in the chart below. Larger systems often require multiple charge controllers operating in parallel.
 
  
The next largest charge controller size should be chosen unless the charge controller manufacturer permits oversizing the array. Common MPPT charge controller current ratings: 10 A, 15 A, 20 A, 25 A, 30 A, 35 A, 40 A, 45 A, 50 A, 55 A, 60 A, 65 A, 70 A, 75 A, 80 A, 85 A, 90 A, 95 A, 100 A.<br />
+
<!--T:18-->
 +
<li>Have a charge controller that can handle the total current supplied by the PV source. An MPPT charge controller is capable of of accepting varying voltages from the PV source and converting them into current at the proper charging voltage for the [[Special:MyLanguage/Energy storage|energy storage system]]. The maximum current of the PV source can be calculated by dividing the power rating of the [[PV module|PV source]] by the [[Special:MyLanguage/DC system voltage|DC system voltage]] as in the chart below. Larger systems often require multiple charge controllers operating in parallel. The next largest charge controller size should be chosen unless the charge controller manufacturer permits oversizing the array. Common MPPT charge controller current ratings: 10 A, 15 A, 20 A, 25 A, 30 A, 35 A, 40 A, 45 A, 50 A, 55 A, 60 A, 65 A, 70 A, 75 A, 80 A, 85 A, 90 A, 95 A, 100 A.</li>
  
 +
<!--T:19-->
 
[[File:Mpptcurrentrating.png|frameless]]
 
[[File:Mpptcurrentrating.png|frameless]]
 +
<li>Can function at the [[Special:MyLanguage/DC system voltage|DC system voltage]]. If a very high current rating is required for the charge controller, increasing the [[Special:MyLanguage/DC system voltage]] can yield a better system design.</li>
 +
</ol>
 +
 +
====Step 4: Final configuration==== <!--T:20-->
 +
 +
<!--T:21-->
 +
It is important to define a few important variables that will be necessary for future steps in the design process.
 +
 +
<!--T:22-->
 +
{| class="wikitable" border=1 style="width: 80%;"
 +
! style="width: 20%"|Final number of PV modules in series
 +
! style="text-align:left;"| =
 +
|}
  
====Step 5: Determine PV source series/parallel configuration====
+
<!--T:23-->
An MPPT charge controller will have a maximum input voltage rating that cannot be exceeded, even under extreme temperatures. This maximum input voltage rating limits the possible configurations of PV modules that can be used to achieve the desired [[Simplified minimum PV source size|minimum PV source size]]. A charge controller must be chosen that:
+
{| class="wikitable" border=1 style="width: 80%;"
#Can unction at the [[DC system voltage]].
+
! style="width: 20%"|Final number of PV source circuits
#Can handle the a PV source series (voltage) and parallel configuration that exceeds the calculated minimum PV source size.
+
! style="text-align:left;"| =
 +
|}
  
 +
<!--T:24-->
 
{| class="wikitable" border=1 style="width: 80%;"
 
{| class="wikitable" border=1 style="width: 80%;"
! style="width: 20%"|PV source power rating
+
! style="width: 20%"|Final PV source power rating
! style="text-align:left;"| = PV module power rating (Step 1) × Number of PV modules in series × Number of PV source circuits must be ''larger than'' [[Simplified minimum PV source size|minimum PV source size]]
+
! style="text-align:left;"| = PV module power rating (Step 1) × Final number of PV modules in series × Final number of PV source circuits
 
|}
 
|}
  
It is necessary to explore various module and charge controller configurations to find the optimal design. The chart below gives maximum and minimum numbers of PV modules in series for 60 and 72 cell modules.
+
<!--T:25-->
 +
{| class="wikitable" border=1 style="width: 80%;"
 +
! style="width: 20%"|Final charge controller current rating
 +
! style="text-align:left;"| =
 +
|}
  
[[File:Mpptseriesparallel.png|frameless]]
+
==Notes/references== <!--T:26-->
  
==Notes/references==
+
<!--T:27-->
 
*60 cell Voc = 41 V
 
*60 cell Voc = 41 V
 
*60 cell Vmp = 27 V
 
*60 cell Vmp = 27 V
 
*72 cell Voc = 50 V
 
*72 cell Voc = 50 V
 
*72 cell Vmp = 34 V
 
*72 cell Vmp = 34 V
TkVoC = -0.36 %/C
+
*TkVoC = -0.36 %/C
TkPmp = -0.48 %/C
+
*TkPmp = -0.48 %/C
 +
</translate>

Latest revision as of 17:06, 6 April 2021

Other languages:
English • ‎español

A MPPT charge controller is rated to operate at a particular DC system voltage, maximum current and maximum voltage. MPPT charge controllers can charge the battery bank with any series and parallel configuration of modules that doesn't exceed the maximum voltage and maximum current or drop below the required charging voltage of the energy storage system. Exceeding the voltage rating of an MPPT due to cold temperatures that increase PV module voltage result in damage. Many charge controllers allow the current rating to be exceeded to a certain point without damage, just lost energy, but this depends on the charge controller. There are several important calculations that must be performed to properly size an MPPT charge controller:

  • Should be sized to work with a series and parallel PV source circuit configuration that will not damage the charge controller due to high voltages resulting from low temperatures at the project location.
  • Should be sized to work with a series and parallel PV source circuit configuration of that will still be able to properly charge the energy storage system under high temperatures and as PV modules age.

Assumptions:

  • Minimum ambient temperature: -15°C
  • Maximum ambient temperature: 50°C
  • Conservative estimates for PV module voltages are used that cover nearly all 60 and 72 cell PV modules.


Step 1: Determine PV module power rating

60-cell and 72-cell modules are the most common module size used with MPPT charge controllers. They range in size from 250W - 400W+.

Step 2: Determine minimum number of PV modules

This calculation will give a minimum number of modules. The final PV source size should always be larger than this value, thus if the result of the calculation is a decimal, it should be rounded up. Different modules sizes and configurations can be explored to find the optimal design.

Minimum number of PV modules = Minimum PV source size ÷ PV module power rating (Step 1)

Step 3: Choose MPPT charge controller and PV source series/parallel configuration

It is necessary to test various different configurations of PV modules and charge controllers to find the best configuration. The DC system voltage, number of PV modules, input voltage of the charge controller, the number of modules in series, the number of parallel circuits, and the current rating of the charge controller can all be varied to find the best design. The final PV source and charge controller configuration must meet the following requirements:

  1. Have a PV source with a final power rating that is higher than the minimum PV source size. This can be achieved through a combination of series and parallel connections.
  2. Have PV source string voltage that does not exceed the maximum input voltage rating of the charge controller, even under extreme temperatures. This maximum input voltage rating limits the possible configurations of PV modules that can be used to reach the minimum number of PV modules calculated in Step 2. The chart below gives maximum and minimum numbers of PV modules in series per PV source circuit for 60 and 72 cell modules. All of the PV source circuits must have the same number of PV modules if there is a single charge controller or else it will not function properly (the number of modules in series therefore must divide evenly into the minimum number of PV modules required). If there are multiple charge controllers, then the number of modules connected in series per PV source circuit should be the same for each one. As long as the voltage doesn't exceed the rating of the charge controller(s), more PV modules per PV source circuit is generally preferable as it permits the use of smaller wires and minimizes voltage drop.
  3. Mpptseriesparallel.png
  4. Have a charge controller that can handle the total current supplied by the PV source. An MPPT charge controller is capable of of accepting varying voltages from the PV source and converting them into current at the proper charging voltage for the energy storage system. The maximum current of the PV source can be calculated by dividing the power rating of the PV source by the DC system voltage as in the chart below. Larger systems often require multiple charge controllers operating in parallel. The next largest charge controller size should be chosen unless the charge controller manufacturer permits oversizing the array. Common MPPT charge controller current ratings: 10 A, 15 A, 20 A, 25 A, 30 A, 35 A, 40 A, 45 A, 50 A, 55 A, 60 A, 65 A, 70 A, 75 A, 80 A, 85 A, 90 A, 95 A, 100 A.
  5. Mpptcurrentrating.png
  6. Can function at the DC system voltage. If a very high current rating is required for the charge controller, increasing the Special:MyLanguage/DC system voltage can yield a better system design.

Step 4: Final configuration

It is important to define a few important variables that will be necessary for future steps in the design process.

Final number of PV modules in series =
Final number of PV source circuits =
Final PV source power rating = PV module power rating (Step 1) × Final number of PV modules in series × Final number of PV source circuits
Final charge controller current rating =

Notes/references

  • 60 cell Voc = 41 V
  • 60 cell Vmp = 27 V
  • 72 cell Voc = 50 V
  • 72 cell Vmp = 34 V
  • TkVoC = -0.36 %/C
  • TkPmp = -0.48 %/C