Difference between revisions of "Design parameter overview"

From Open Source Solar Project
Jump to navigation Jump to search
(Created page with "The design process requires the person performing the design to select values for various different design coefficients that will be used through the rest of the design proces...")
 
 
(16 intermediate revisions by the same user not shown)
Line 1: Line 1:
The design process requires the person performing the design to select values for various different design coefficients that will be used through the rest of the design process. Some of desiggn coefficients have values that are recommended based upon industry practices, but there are others that will require the designer to make a determination that strikes the right balance between the [[Weather and solar resource evaluation|available weather and solar resource]], [[Load evaluation|load and usage estimates]], and budget vary for each off-grid PV project. Different values for critical coefficients like Depth of Discharge, Days of Autonomy, and System voltage should be tested during the design process to find the optimal design for the system.
+
[[Category:Design parameters]]
*'''Depth of Discharge:'''
+
<languages />
*'''Days of Autonomy:'''
+
<translate>
*'''System voltage:'''
+
<!--T:1-->
*'''Charge controller efficiency:'''
+
The design process requires the person performing the design to select values for various different design parameters that will be used through the rest of the design process. Some of desiggn coefficients have values that are recommended based upon industry practices, but there are others that will require the designer to determine a value that strikes the right balance between the [[Special:MyLanguage/Weather and solar resource evaluation|weather and solar resource]], [[Special:MyLanguage/Load evaluation|load and usage estimates]], and budget. Different values for critical coefficients like depth of discharge, days of autonomy, and system voltage should be tested during the design process to find the optimal design for the system.
*'''Low voltage disconnect:'''
+
 
*'''Module degradation:'''
+
<!--T:2-->
*'''Irradiance safety factor:'''
+
*'''[[Special:MyLanguage/DC system voltage|DC system voltage]]:''' Parameter for the nominal voltage for the direct current (DC) system.
*'''Continuous duty safety factor:'''
+
 
*'''Maximum system charging voltage:'''
+
<!--T:3-->
 +
*'''[[Special:MyLanguage/Irradiance safety parameter|MyLanguage/Irradiance safety parameter]]:''' Parameter to ensure that system components can handle periods of high irradiance.
 +
 
 +
<!--T:4-->
 +
*'''[[Special:MyLanguage/Continuous duty safety parameter|Continuous duty safety parameter]]:''' Parameter to ensure that system components can handle periods of high sustained current.
 +
 
 +
<!--T:5-->
 +
*'''[[Special:MyLanguage/Low voltage disconnect parameter|Low voltage disconnect parameter]]:''' Parameter that determines when the system will shut off due to low voltage/ or insufficient stored energy.
 +
 
 +
==Notes/references== <!--T:6-->
 +
</translate>

Latest revision as of 11:03, 1 April 2021

Other languages:
English • ‎español

The design process requires the person performing the design to select values for various different design parameters that will be used through the rest of the design process. Some of desiggn coefficients have values that are recommended based upon industry practices, but there are others that will require the designer to determine a value that strikes the right balance between the weather and solar resource, load and usage estimates, and budget. Different values for critical coefficients like depth of discharge, days of autonomy, and system voltage should be tested during the design process to find the optimal design for the system.

  • DC system voltage: Parameter for the nominal voltage for the direct current (DC) system.

Notes/references