Difference between revisions of "Translations:Energy storage sizing and selection/20/es"
Jump to navigation
Jump to search
(Created page with "{| class="wikitable" border=1 style="width: 80%;" ! style="width: 20%"|Ah requerido total ! style="text-align:left;"| = Special:MyLanguage/Load and solar resource comparison...") |
|||
(4 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
{| class="wikitable" border=1 style="width: 80%;" | {| class="wikitable" border=1 style="width: 80%;" | ||
− | ! style="width: 20%"|Ah requerido | + | ! style="width: 20%"|El mínimo de Ah requerido |
− | ! style="text-align:left;"| = [[Special:MyLanguage/Load and solar resource comparison| | + | ! style="text-align:left;"| = [[Special:MyLanguage/Load and solar resource comparison|Los vatio-horas diarios de diseño requeridos]] ÷ [[Special:MyLanguage/DC system voltage|La tensión de CC del sistema]] × El factor de corrección de temperatura (Paso 3) × El parámetro de días de autonomía (Paso 2) ÷ El parámetro de profundidad de descarga (Paso 1) |
|} | |} |
Latest revision as of 15:59, 1 April 2021
El mínimo de Ah requerido | = Los vatio-horas diarios de diseño requeridos ÷ La tensión de CC del sistema × El factor de corrección de temperatura (Paso 3) × El parámetro de días de autonomía (Paso 2) ÷ El parámetro de profundidad de descarga (Paso 1) |
---|