Difference between revisions of "Main Page"

From Open Source Solar Project
Jump to navigation Jump to search
 
(248 intermediate revisions by the same user not shown)
Line 1: Line 1:
 +
<languages />
 
<translate>
 
<translate>
 
<!--T:1-->
 
<!--T:1-->
<strong>Welcome to The Open Source Solar Project</strong>
+
<strong>Welcome to the Open Source Solar Project</strong>
  
 
<!--T:2-->
 
<!--T:2-->
The sun is the ultimate open source - available to everyone to do what they would like with the energy it provides. OSSP is a collaborative, multi-lingual effort to improve off-grid solar PV system design, safety, and user experiences in areas of the world that lack well-developed standards or appropriate training programs. The project will create a universal, adaptable framework for off-grid PV system design with all of the necessary tools and resources to serve as both a direct resource in these areas and as a readily-adaptable base for the development of training materials that are tailored to the needs and standards of a particular area. OSSP is license-free running on the same platform as Wikipedia - please reach out to alex@opensourcesolar.org if you are interested in contributing or translating.
+
The mission of Open Source Solar Project is to share information in various langauges about the design and installation of off-grid photovoltaic (PV) systems to lead to better performing, safer systems in the developing world. Please reach out to alex@opensourcesolar.org if you are interested in collaborating, have found mistakes, would like to contribute or need assistance creating training materials.
  
 
<!--T:3-->
 
<!--T:3-->
Goals of OSSP:
+
Be advised that design, installation, and maintenance work should only be performed by qualified individuals in accordance with local codes and laws. There is no guarantee that the information provided on this website is accurate or complete - use it at your own risk. It is intended to serve as an educational and reference resource - appropriate hands on training is required in order to safely work with electricity and PV systems. See [[Special:MyLanguage/Training providers|Training providers]] for a list of recommended training providers.
*Provide infomation that is acessible and practical for an audience with a varying level of technology literacy.
 
*Present universal concepts in a way that is universal. Information or resources that are location specific should be added to a country page.
 
*Only utilize graphics or content added must be in the public domain.  
 
*Utilize graphics should with text only as completely necessary to enable easy translation.
 
  
<!--T:4-->
 
 
Consult the [https://www.mediawiki.org/wiki/Special:MyLanguage/Help:Contents User's Guide] for information on using the wiki software.
 
Consult the [https://www.mediawiki.org/wiki/Special:MyLanguage/Help:Contents User's Guide] for information on using the wiki software.
 +
==About OSSP== <!--T:29-->
 +
 +
<!--T:30-->
 +
*[[Special:MyLanguage/About OSSP|About OSSP]]<br />
 +
 +
==Basic concepts== <!--T:5-->
 +
*[[Special:MyLanguage/What is an off-grid PV system?|What is an off-grid (stand-alone) PV system?]]<br />
 +
*[[Special:MyLanguage/PV system types|PV system types]]<br />
 +
*[[Special:MyLanguage/Basic stand-alone PV system components|Basic stand-alone PV system components]]<br />
 +
*[[Special:MyLanguage/Electricity and energy|Electricity and energy]]<br />
 +
*[[Special:MyLanguage/Electricity types|Electricity types]]<br />
 +
*[[Special:MyLanguage/Voltage and frequency by country|Voltage and frequency by country]]<br />
 +
*[[Special:MyLanguage/Power flow between components|Power flow between components]]<br />
 +
*[[Special:MyLanguage/Series and parallel connections|Series and parallel connections]]<br />
 +
*[[Special:MyLanguage/Electrical codes|Electrical codes]]<br />
 +
*[[Special:MyLanguage/Electrical safety|Electrical safety]]<br />
 +
*[[Special:MyLanguage/Multimeters|Multimeters]]<br />
 +
 +
==System components== <!--T:8-->
 +
====Certifications and ratings====
 +
*[[Special:MyLanguage/Equipment certification|Equipment certification]]<br />
 +
*[[Special:MyLanguage/Weather rating|Weather rating]]<br />
 +
 +
====Photovoltaic (PV) source==== <!--T:9-->
 +
*[[Special:MyLanguage/PV module|PV module (PV source, solar panel)]]<br />
 +
*[[Special:MyLanguage/Insolation|Insolation (peak sun hours)]]<br />
 +
*[[Special:MyLanguage/Tilt and azimuth|Tilt and azimuth]]<br />
 +
*[[Special:MyLanguage/Shading|Shading]]<br />
 +
*[[Special:MyLanguage/Module connectors|Module connectors]]<br />
 +
*[[Special:MyLanguage/Combiner box|Combiner box]]<br />
 +
====Energy storage====
 +
*[[Special:MyLanguage/Energy storage|Energy storage]]<br />
 +
*[[Special:MyLanguage/Lead acid battery|Lead acid battery]]<br />
 +
*[[Special:MyLanguage/Lithium-ion battery|Lithium-ion battery]]<br />
 +
*[[Special:MyLanguage/Shunt|Shunt]]<br />
 +
 +
====Charge controller==== <!--T:10-->
 +
*[[Special:MyLanguage/Charge controller|Charge controller]]<br />
 +
====Inverter====
 +
*[[Special:MyLanguage/Inverter|Inverter]]<br />
 +
====Power distribution====
 +
*[[Special:MyLanguage/Distribution panel|Distribution panel]]<br />
 +
*[[Special:MyLanguage/DIN rail|DIN rail]]<br />
 +
*[[Special:MyLanguage/Busbar|Busbar]]<br />
 +
*[[Special:MyLanguage/Wire terminal|Wire terminal]]<br />
 +
*[[Special:MyLanguage/Twist-on wire connector|Twist-on wire connector (wire nut, marrette)]]<br />
 +
*[[Special:MyLanguage/Switch|Switch]]<br />
 +
*[[Special:MyLanguage/Outlet|Outlet]]<br />
 +
 +
====Mounting system==== <!--T:11-->
 +
*[[Special:MyLanguage/Mounting system types|Mounting system types]]<br />
 +
 +
====Conductors (wires, cables)==== <!--T:28-->
 +
*[[Special:MyLanguage/Conductor types|Conductor types]]<br />
 +
*[[Special:MyLanguage/Conductor size|Conductor size]]<br />
 +
*[[Special:MyLanguage/Insulation color|Insulation color]]<br />
 +
 +
====Physical conductor protection==== <!--T:12-->
 +
*[[Special:MyLanguage/Conduit|Conduit]]<br />
 +
*[[Special:MyLanguage/Junction box|Junction box]]<br />
 +
====Protection devices and disconnects====
 +
*[[Special:MyLanguage/Overcurrent protection device|Overcurrent protection device (OCPD)]]<br />
 +
*[[Special:MyLanguage/Disconnects|Disconnects]]<br />
 +
*[[Special:MyLanguage/Residual current device|Residual current device (RCD or GFCI)]]<br />
 +
*[[Special:MyLanguage/Ground fault protection device|Ground fault protection device (GFPD)]]<br />
 +
====Grounding====
 +
*[[Special:MyLanguage/Grounding system|Grounding system]]<br />
 +
 +
====Loads (lighting and appliances)==== <!--T:13-->
 +
*[[Special:MyLanguage/Lighting|Lighting]]<br />
 +
*[[Special:MyLanguage/Energy efficient loads|Energy efficient loads]]<br />
 +
*[[Special:MyLanguage/Low voltage disconnect|Low voltage disconnect]]<br />
 +
*[[Special:MyLanguage/DC-DC converter|DC-DC converter]]<br />
 +
 +
==System design== <!--T:14-->
 +
===Design tools===
 +
*[[Special:MyLanguage/OSSP stand-alone system design tool|OSSP stand-alone system design tool]]
 +
 +
===Background=== <!--T:15-->
 +
*[[Special:MyLanguage/Design process overview|Design process overview]]<br />
 +
*[[Special:MyLanguage/Stand-alone system configurations|Stand-alone system configurations]]<br />
 +
*[[Special:MyLanguage/DC system voltage|DC system voltage]]<br />
 +
*[[Special:MyLanguage/Voltage drop|Voltage drop]]<br />
 +
*[[Special:MyLanguage/Surge loads|Surge loads]]<br />
 +
*[[Special:MyLanguage/Power factor|Power factor]]<br />
 +
*[[Special:MyLanguage/Duty cycle|Duty cycle]]<br/>
 +
 +
===Site evaluation=== <!--T:16-->
 +
*[[Special:MyLanguage/Site evaluation process overview|Site evaluation process overview]]<br />
 +
====Simplified design process====
 +
*[[Special:MyLanguage/Simplified physical evaluation|Simplified physical evaluation]]<br />
 +
*[[Special:MyLanguage/Simplified load evaluation|Simplified load evaluation]]<br />
 +
*[[Special:MyLanguage/Simplified weather and solar resource evaluation|Simplified weather and solar resource evaluation]]<br />
 +
====Detailed design process====
 +
*[[Special:MyLanguage/Load evaluation|Load evaluation]]<br />
 +
*[[Special:MyLanguage/Physical evaluation|Physical evaluation]]<br />
 +
*[[Special:MyLanguage/Weather and solar resource evaluation|Weather and solar resource evaluation]]<br />
 +
*[[Special:MyLanguage/Load and solar resource comparison|Load and solar resource comparison]]<br />
 +
 +
===Design parameters=== <!--T:17-->
 +
====Simplified design process====
 +
*All design parameters are incorporated into the other simplified design process pages.
 +
====Detailed design process====
 +
*[[Special:MyLanguage/Design parameter overview|Design parameter overview]]<br />
 +
*[[Special:MyLanguage/Irradiance safety parameter|Irradiance safety parameter]]<br />
 +
*[[Special:MyLanguage/Continuous duty safety parameter|Continous duty safety parameter]]<br />
 +
*[[Special:MyLanguage/Low voltage disconnect parameter|Low voltage disconnect parameter]]<br />
 +
 +
===Energy storage sizing and selection=== <!--T:18-->
 +
====Simplified design process====
 +
*[[Special:MyLanguage/Simplified energy storage sizing and selection|Simplified energy storage sizing and selection]]<br />
 +
====Detailed design process====
 +
*[[Special:MyLanguage/Energy storage sizing and selection|Energy storage sizing and selection]]<br />
 +
 +
===PV source and charge controller sizing and selection=== <!--T:19-->
 +
*[[Special:MyLanguage/PV source and charge controller sizing and selection overview|PV source and charge controller sizing and selection overview]]<br />
 +
====Simplified design process====
 +
*[[Special:MyLanguage/Simplified minimum PV source size|Simplified minimum PV source size]]<br />
 +
*[[Special:MyLanguage/Simplified PWM charge controller sizing and selection|Simplified PWM charge controller sizing and selection]]<br />
 +
*[[Special:MyLanguage/Simplified MPPT charge controller sizing and selection|Simplified MPPT charge controller sizing and selection]]<br />
 +
====Detailed design process====
 +
*[[Special:MyLanguage/Minimum PV source size|Minimum PV source size]]<br />
 +
*[[Special:MyLanguage/PWM charge controller sizing and selection|PWM charge controller sizing and selection]]<br />
 +
*[[Special:MyLanguage/MPPT charge controller sizing and selection|MPPT charge controller sizing and selection]]<br />
 +
 +
===Inverter sizing and selection=== <!--T:20-->
 +
====Simplified design process====
 +
*[[Special:MyLanguage/Simplified inverter sizing and selection|Simplified inverter sizing and selection]]<br />
 +
====Detailed design process====
 +
*[[Special:MyLanguage/Inverter sizing and selection|Inverter sizing and selection]]<br />
 +
 +
===Wire, overcurrent protection, and disconnect sizing and selection=== <!--T:21-->
 +
====Simplified design process====
 +
*[[Special:MyLanguage/Simplified wire, overcurrent protection, and disconnect sizing and selection|Simplified wire, overcurrent protection, and disconnect sizing and selection]]
 +
====Detailed design process====
 +
*[[Special:MyLanguage/Wire, overcurrent protection, and disconnect sizing and selection|Wire, overcurrent protection, and disconnect sizing and selection]]
 +
 +
===Grounding system sizing and selection=== <!--T:22-->
 +
====Simplified design process====
 +
*[[Special:MyLanguage/Simplified grounding system sizing and selection|Simplified grounding system sizing and selection]]<br />
 +
====Detailed design process====
 +
*[[Special:MyLanguage/Grounding system sizing and selection|Grounding system sizing and selection]]<br />
 +
 +
==Design examples== <!--T:23-->
 +
*[[Special:MyLanguage/Detailed DC system design|Detailed DC system design]]<br />
 +
*[[Special:MyLanguage/Detailed AC/DC system design|Detailed AC/DC system design]]<br />
 +
*[[Special:MyLanguage/Detailed AC system design|Detailed AC system design]]<br />
 +
 +
==System installation== <!--T:24-->
 +
*[[Special:MyLanguage/Principles of installation|Principles of installation]]<br />
 +
*[[Special:MyLanguage/Equipment clearances and safe working space|Equipment clearances and safe working space]]<br />
 +
*[[Special:MyLanguage/Wiring practices|Wiring practices]]<br />
 +
*[[Special:MyLanguage/Wiring basic load circuits|Wiring basic load circuits]]<br />
 +
*[[Special:MyLanguage/Battery wiring|Battery wiring]]<br/>
 +
*[[Special:MyLanguage/Installing module connectors|Installing module connectors]]<br />
 +
*[[Special:MyLanguage/Charge controller programming|Charge controller programming]]<br />
 +
*[[Special:MyLanguage/Inverter programming|Inverter programming]]<br />
 +
*[[Special:MyLanguage/Labeling|Labeling]]<br />
 +
*[[Special:MyLanguage/Commissioning|Commissioning]]<br />
 +
 +
==Operations and maintenance== <!--T:25-->
 +
*[[Special:MyLanguage/Troubleshooting|Troubleshooting]]
 +
 +
==Resources== <!--T:26-->
 +
*[[Special:MyLanguage/Resources|Resources]]<br />
 +
*[[Special:MyLanguage/Training providers|Training providers]]<br />
 +
 +
==Country pages== <!--T:27-->
 +
*[[Special:MyLanguage/Colombia|Colombia]]
 +
*[[Special:MyLanguage/Peru|Peru]]
 +
*[[Special:MyLanguage/United States|United States]]
  
== Primary articles == <!--T:5-->
 
All links with arrows next to them are categories, not articles. Click on the arrow to expand the category to show the pages in that category. Most categories will have a page that has the same name that will be the best place to start.
 
<categorytree mode="pages">Basics</categorytree>
 
<categorytree mode="pages">Components</categorytree>
 
<categorytree mode="pages">System design</categorytree>
 
<categorytree mode="pages">Design resources</categorytree>
 
<categorytree mode="pages">Country pages</categorytree>
 
  
 
</translate>
 
</translate>

Latest revision as of 16:44, 5 April 2021

Other languages:
English • ‎español

Welcome to the Open Source Solar Project

The mission of Open Source Solar Project is to share information in various langauges about the design and installation of off-grid photovoltaic (PV) systems to lead to better performing, safer systems in the developing world. Please reach out to alex@opensourcesolar.org if you are interested in collaborating, have found mistakes, would like to contribute or need assistance creating training materials.

Be advised that design, installation, and maintenance work should only be performed by qualified individuals in accordance with local codes and laws. There is no guarantee that the information provided on this website is accurate or complete - use it at your own risk. It is intended to serve as an educational and reference resource - appropriate hands on training is required in order to safely work with electricity and PV systems. See Training providers for a list of recommended training providers.

Consult the User's Guide for information on using the wiki software.

About OSSP

Basic concepts

System components

Certifications and ratings

Photovoltaic (PV) source

Energy storage

Charge controller

Inverter

Power distribution

Mounting system

Conductors (wires, cables)

Physical conductor protection

Protection devices and disconnects

Grounding

Loads (lighting and appliances)

System design

Design tools

Background

Site evaluation

Simplified design process

Detailed design process

Design parameters

Simplified design process

  • All design parameters are incorporated into the other simplified design process pages.

Detailed design process

Energy storage sizing and selection

Simplified design process

Detailed design process

PV source and charge controller sizing and selection

Simplified design process

Detailed design process

Inverter sizing and selection

Simplified design process

Detailed design process

Wire, overcurrent protection, and disconnect sizing and selection

Simplified design process

Detailed design process

Grounding system sizing and selection

Simplified design process

Detailed design process

Design examples

System installation

Operations and maintenance

Resources

Country pages